Department of Electrical Engineering, Technical University of Eindhoven, Eindhoven, The Netherlands; Department of Anesthesiology, Pain Therapy and Intensive Care, Catharina Hospital, Eindhoven,The Netherlands

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2022 in Physiological Measurement
Verified
Journal Article
Open access
ISIrene Suriani
Irene Suriani
JHJoris van Houte
Joris van Houte
EBEsmée C de Boer
Esmée C de Boer
LKLuuk van Knippenberg
Luuk van Knippenberg
SMSabina Manzari
Sabina Manzari
RBR. Arthur Bouwman
R. Arthur Bouwman
Objective. Accurate haemodynamic monitoring is the cornerstone in the management of critically ill patients. It guides the optimization of tissue and organ perfusion in order to prevent multiple organ failure. In the past decades, carotid Doppler ultrasound (CDU) has been explored as a non-invasive alternative for long-established invasive haemodynamic monitoring techniques. Considering the large heterogeneity in reported studies, we conducted a review of the literature to clarify the current status of CDU as a haemodynamic monitoring tool. Approach. In this article, firstly an overview is given of the equipment and workflow required to perform a CDU exam in clinical practice, the limitations and technical challenges potentially faced by the CDU sonographer, and the cerebrovascular mechanisms that may influence CDU measurement outcomes. The following chapter describes alternative techniques for non-invasive haemodynamic monitoring, detailing advantages and limitations compared to CDU. Next, a comprehensive review of the literature regarding the use of CDU for haemodynamic monitoring is presented. Furthermore, feasibility aspects, training requirements and technical developments of CDU are addressed. Main results. Based on the outcomes of these studies, we assess the applicability of CDU-derived parameters within three clinical domains (cardiac output, volume status, and fluid responsiveness), and amongst different patient groups. Finally, recommendations are provided to improve the quality and standardization of future research and clinical practice in this field. Significance. Although CDU is not yet interchangeable with invasive ‘gold standard’ cardiac output monitoring, the present work shows that certain CDU-derived parameters prove promising in the context of functional haemodynamic monitoring.

8 March 2025 in Perioperative Medicine
Verified
Journal Article
Open access
PDF file
EBEsmée C. de Boer
Esmée C. de Boer
JHJoris van Houte
Joris van Houte
CFCatarina Dinis Fernandes
Catarina Dinis Fernandes
TBTom Bakkes
Tom Bakkes
JMJens Muehlsteff
Jens Muehlsteff
MMMassimo Mischi
Massimo Mischi
The induction of spinal anesthesia is often followed by hypotension, which has been associated with post-operative end-organ damage. A timely prediction of spinal anesthesia-induced hypotension (SAIH) paired with appropriate interventions may reduce the risk of adverse outcomes. This study investigated the value of carotid Doppler ultrasound measurements and clinical variables, both individually and combined, to predict SAIH. Adult patients who were scheduled for elective surgery under spinal anesthesia were included. Carotid ultrasound imaging and baseline vital sign measurements were performed pre-operatively, well in advance of the induction of spinal anesthesia. The occurrence of hypotension was observed for ten minutes after the induction of spinal anesthesia. Logistic regression models studied linear relationships within the derived set of ultrasound and clinical features, and support vector machine models evaluated nonlinear relationships. A total of 40 patients were included, and 45% of them developed SAIH. The logistic regression models performed better than the support vector machine models. The best-performing logistic regression model combined carotid ultrasound and clinical features and had a sensitivity of 75 [73–81]%, specificity of 75 [71–81]%, AUROC of 0.81 [0.75—0.95], positive predictive value of 75 [65–81]%, negative predictive value of 75 [71–88]% and F1 score of 0.75 [0.71–0.76]. The key features that were shown to predict SAIH were baseline mean arterial pressure, fasting time, ASA class, and weight. Combining carotid Doppler ultrasound measurements and clinical variables can predict the occurrence of SAIH. The study was retrospectively registered at clinicaltrials.gov (NCT06711289) on 2 December 2024.

3 June 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ISIrene Suriani
Irene Suriani
ABAgata Barbagini
Agata Barbagini
EBEsmée C. de Boer
Esmée C. de Boer
STSimona Turco
Simona Turco
KLKevin D. Lau
Kevin D. Lau
Massimo MischiMassimo Mischi
Massimo Mischi
Local carotid pulse wave velocity (cPWV), a hemodynamic variable related to arterial stiffness, is a recognized risk indicator for cardiovascular disease. Yet, current methods for its estimation pose challenges, requiring multiple simultaneous local measurements, as is the case for the established Bramwell-Hill (BH) method, or relying on assumptions that may not universally apply, as for single-measurement loop-based methods. This study introduces a novel, non-invasive, single-measurement method for estimating local cPWV. The proposed method relies solely on morphological indices derived from the carotid velocity waveform, measured via pulsed wave Doppler (pw-D) ultrasound. A multivariate regression (MVR) model relating eight such indices to cPWV was trained on a large available virtual cohort (N=5,160), previously generated via one-dimensional hemodynamic modeling. The MVR model was then tested on a clinical dataset of 27 cardiac surgery patients, showing moderate but significant correlation with the reference Bramwell-Hill method (r=0.54, p<0.01), and Bland-Altman values falling within clinically acceptable thresholds (mean difference 0.16 m/s, limits of agreement ±1.98 m/s). The proposed method outperformed the alternative pressure-less flow-area loop (QA-loop) method, which compared poorly to reference BH values (r=0.47, p<0.05, mean difference 0.72 m/s, and limits of agreement ±5.41 m/s). Furthermore, the proposed method showed the lowest intra-subject coefficient of variation (median 2.4%, interquartile range (IQR) 0-4.2%), and measurement-related uncertainty (median 0.11 m/s, IQR 0.07-0.23 m/s) among the three compared methods.

10 October 2023 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
FRFrederique M. de Raat
Frederique M. de Raat
JHJoris van Houte
Joris van Houte
LMLeon. J. Montenij
Leon. J. Montenij
SBSjoerd Bouwmeester
Sjoerd Bouwmeester
SFSuzanne E. A. Felix
Suzanne E. A. Felix
RBR. Arthur Bouwman
R. Arthur Bouwman
Bedside quantification of stroke volume (SV) and left ventricular ejection fraction (LVEF) is valuable in hemodynamically compromised patients. Miniaturized handheld ultrasound (HAND) devices are now available for clinical use. However, the performance level of HAND devices for quantified cardiac assessment is yet unknown. The aim of this study was to compare the validity of HAND measurements with standard echocardiography (SE) and three-dimensional echocardiography (3DE). Thirty-six patients were scanned with HAND, SE and 3DE. LVEF and SV quantification was done with automated software for the HAND, SE and 3DE dataset. The image quality of HAND and SE was evaluated by scoring segmental endocardial border delineation (2 = good, 1 = poor, 0 = invisible). LVEF and SV of HAND was evaluated against SE and 3DE using correlation and Bland–Altman analysis. The correlation, bias, and limits of agreement (LOA) between HAND and SE were 0.68 [0.46:0.83], 1.60% [− 2.18:5.38], and 8.84% [− 9.79:12.99] for LVEF, and 0.91 [0.84:0.96], 1.32 ml [− 0.36:4.01], 15.54 ml [− 18.70:21.35] for SV, respectively. Correlation, bias, and LOA between HAND and 3DE were 0.55 [0.6:0.74], − 0.56% [− 2.27:1.1], and 9.88% [− 13.29:12.17] for LVEF, and 0.79 [0.62:0.89], 6.78 ml [2.34:11.21], 12.14 ml [− 26.32:39.87] for SV, respectively. The image quality scores were 9.42 ± 2.0 for the apical four chamber views of the HAND dataset and 10.49 ± 1.7 for the SE dataset and (P < 0.001). Clinically acceptable accuracy, precision, and image quality was demonstrated for HAND measurements compared to SE. In comparison to 3DE, HAND showed a clinically acceptable accuracy and precision for LVEF quantification.

26 December 2025 in Journal of Cardiothoracic and Vascular Anesthesia
Verified
Journal Article
Open access
FRFrederique M. de Raat
Frederique M. de Raat
EBEsmée C. de Boer
Esmée C. de Boer
IPIgor W.F. Paulussen
Igor W.F. Paulussen
JHJoris van Houte
Joris van Houte
RBR. Arthur Bouwman
R. Arthur Bouwman
LMLeon J. Montenij
Leon J. Montenij
Ventricular-arterial coupling (VAC), defined as the ratio of arterial elastance (Ea) to left ventricular end-systolic elastance (Ees), provides valuable insights for optimizing perioperative hemodynamic management. While transthoracic echocardiography and transesophageal echocardiography (TEE) are used to estimate Ees, both modalities require substantial operator expertise and transthoracic echocardiography may be limited by suboptimal imaging conditions, especially in the perioperative setting. Therefore, the authors propose using carotid ultrasound as a noninvasive and more accessible alternative to estimate VAC. Given its close anatomic and physiological relationship with the proximal aorta, the carotid artery reflects central arterial hemodynamics and may serve as a promising surrogate for VAC. This study aimed to evaluate the agreement between carotid ultrasound and TEE in measuring VAC in patients undergoing cardiac surgery. Prospective observational pilot study. Operating room. Twelve adult patients undergoing elective coronary artery bypass grafting surgery. Ultrasound measurements were obtained both preoperatively and postoperatively using carotid ultrasound and TEE, and the interchangeability between Ea, Ees, and VAC was evaluated with correlation and Bland-Altman analyses. Ea was calculated using the systolic blood pressure and stroke volume, while Ees was estimated using the single-beat method proposed by Chen et al. MEASUREMENTS AND MAIN RESULTS: Strong correlations were observed between carotid ultrasound and TEE measurements for Ea (r = 0.87; 95% confidence interval [CI], 0.73-0.95), Ees (r = 0.82; 95% CI, 0.63-0.92), and VAC (r = 0.79; 95% CI, 0.56-0.90). The estimation of VAC using carotid ultrasound demonstrated clinically acceptable accuracy and precision, with a bias of -0.01 (95% CI, -0.07 to 0.05) and limits of agreement of ±0.30 (range, -0.18 to 0.39). Carotid ultrasound-derived VAC demonstrated good correlation with VAC measured using TEE in this pilot study. These preliminary results suggest that carotid ultrasound may be useful for investigating VAC at the bedside, but further studies with larger sample sizes are needed to validate these findings.

1 March 2024 in Physiological Measurement
Verified
Journal Article
Open access
EBEsmée C de Boer
Esmée C de Boer
CFCatarina Dinis Fernandes
Catarina Dinis Fernandes
DNDanihel van Neerven
Danihel van Neerven
CPChristoph Pennings
Christoph Pennings
RJRohan Joshi
Rohan Joshi
Massimo MischiMassimo Mischi
Massimo Mischi
Objective . Carotid ultrasound (US) has been studied as a non-invasive alternative for hemodynamic monitoring. A long-axis (LA) view is traditionally employed but is difficult to maintain and operator experience may impact the diameter estimates, making it unsuitable for monitoring. Preliminary results show that a new, i.e. rotated and tilted (RT) view is more robust to motion and less operator-dependent. This study aimed to quantitatively assess common carotid diameter estimates obtained in a clinical setting from an RT view and compare those to corresponding estimates obtained using other views. Approach . Carotid US measurements were performed in 30 adult cardiac-surgery patients (26 males, 4 females) with short-axis (SA), LA, and RT probe orientations, the first being used as a reference for measuring the true vessel diameter. Per 30 s acquisition, the median and spread in diameter values were computed, the latter representing a measure of robustness, and were statistically compared between views. Main results . The median (IQR) over all the patients of the median diameter per 30 s acquisition was 7.15 (1.15) mm for the SA view, 7.03 (1.51) mm for the LA view, and 6.99 (1.72) mm for the RT view. The median spread in diameter values was 0.18 mm for the SA view, 0.16 mm for the LA view, and 0.18 mm for the RT view. There were no statistically significant differences between views in the median diameter values ( p = 0.088) or spread ( p = 0.122). Significance . The RT view results in comparable and equally robust median carotid diameter values compared to the reference. These findings open the path for future studies investigating the use of the RT view in new applications, such as in wearable ultrasound devices.