Igor W.F. Paulussen

Igor W.F. Paulussen

Auto-generated profile, based on publicly available information

Igor W.F. Paulussen

Catharina Hospital Eindhoven

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2026 in Journal of Applied Physiology
Verified
Journal Article
Open access
RDRuby Dunphy
Ruby Dunphy
SQSjeng Quicken
Sjeng Quicken
JKJur Van Kimmenade
Jur Van Kimmenade
JMJulianna Mangold
Julianna Mangold
MSMehdi Shekarnabi
Mehdi Shekarnabi
SBSam BAYAT
Sam BAYAT
This study presents a computational model for simulating ventilatory response in mechanically ventilated patients with acute respiratory distress syndrome and introduces a novel method to estimate patient-specific lung mechanical properties from a dual-volume computed tomography (CT) protocol. The key purpose of the in silico model proposed in this paper is to provide clinicians with a complementary modality that supports decision-making surrounding mechanical ventilation.

26 December 2025 in Journal of Cardiothoracic and Vascular Anesthesia
Verified
Journal Article
Open access
FRFrederique M. de Raat
Frederique M. de Raat
EBEsmée C. de Boer
Esmée C. de Boer
IPIgor W.F. Paulussen
Igor W.F. Paulussen
JHJoris van Houte
Joris van Houte
RBR. Arthur Bouwman
R. Arthur Bouwman
LMLeon J. Montenij
Leon J. Montenij
Ventricular-arterial coupling (VAC), defined as the ratio of arterial elastance (Ea) to left ventricular end-systolic elastance (Ees), provides valuable insights for optimizing perioperative hemodynamic management. While transthoracic echocardiography and transesophageal echocardiography (TEE) are used to estimate Ees, both modalities require substantial operator expertise and transthoracic echocardiography may be limited by suboptimal imaging conditions, especially in the perioperative setting. Therefore, the authors propose using carotid ultrasound as a noninvasive and more accessible alternative to estimate VAC. Given its close anatomic and physiological relationship with the proximal aorta, the carotid artery reflects central arterial hemodynamics and may serve as a promising surrogate for VAC. This study aimed to evaluate the agreement between carotid ultrasound and TEE in measuring VAC in patients undergoing cardiac surgery. Prospective observational pilot study. Operating room. Twelve adult patients undergoing elective coronary artery bypass grafting surgery. Ultrasound measurements were obtained both preoperatively and postoperatively using carotid ultrasound and TEE, and the interchangeability between Ea, Ees, and VAC was evaluated with correlation and Bland-Altman analyses. Ea was calculated using the systolic blood pressure and stroke volume, while Ees was estimated using the single-beat method proposed by Chen et al. MEASUREMENTS AND MAIN RESULTS: Strong correlations were observed between carotid ultrasound and TEE measurements for Ea (r = 0.87; 95% confidence interval [CI], 0.73-0.95), Ees (r = 0.82; 95% CI, 0.63-0.92), and VAC (r = 0.79; 95% CI, 0.56-0.90). The estimation of VAC using carotid ultrasound demonstrated clinically acceptable accuracy and precision, with a bias of -0.01 (95% CI, -0.07 to 0.05) and limits of agreement of ±0.30 (range, -0.18 to 0.39). Carotid ultrasound-derived VAC demonstrated good correlation with VAC measured using TEE in this pilot study. These preliminary results suggest that carotid ultrasound may be useful for investigating VAC at the bedside, but further studies with larger sample sizes are needed to validate these findings.

17 November 2025 in Ultrasound in Medicine & Biology
Verified
Journal Article
Open access
EBEsmée C. de Boer
Esmée C. de Boer
FRFrederique M. de Raat
Frederique M. de Raat
CFCatarina Dinis Fernandes
Catarina Dinis Fernandes
JHJoris van Houte
Joris van Houte
IPIgor W.F. Paulussen
Igor W.F. Paulussen
Massimo MischiMassimo Mischi
Massimo Mischi
Perioperative hemodynamic monitoring plays a crucial role in reducing complications during coronary artery bypass graft (CABG) surgery. Corrected left ventricular ejection time (cLVET) is used to assess cardiac contractility but requires specialized echocardiography expertise. Corrected carotid flow time (ccFT), a non-invasive carotid Doppler-based method, could serve as an alternative, but its agreement with cLVET in CABG patients remains uncertain. This study evaluates the clinical agreement between these two measures in a real-world clinical setting. In this prospective observational study, 17 adult patients undergoing CABG surgery were included. cLVET was measured using transesophageal echocardiography, while ccFT was assessed via carotid ultrasound, both before incision and after thoracic closure. All values were calculated using Bazett's and Wodey's formulas, manually and through an automated algorithm. Correlation, Bland-Altman, and concordance analyses were conducted to evaluate the relationships between the measures. Manual quantification showed better clinical agreement than automated analysis. Manually-derived ccFT values showed a strong correlation with cLVET using Bazett's formula (r = 0.88, 95% CI [0.77-0.94], p < 0.001) and Wodey's formula (r = 0.96, 95% CI [0.91-0.98], p < 0.001), with an acceptable bias (<11 ms) and narrow limits of agreement (Bazett: -35 to 57 ms; Wodey: -15 to 35 ms). Concordance was acceptable for Bazett (91%) and good for Wodey (93%). While automated quantification yielded poor clinical agreement, manually computed ccFT demonstrated a strong clinical agreement with cLVET. This suggests that manually derived ccFT values could serve as a viable surrogate for cLVET. Further effort is needed to optimize automated algorithms for future clinical applications.