Jonathan Eastman

Jonathan Eastman

Auto-generated profile, based on publicly available information

Jonathan Eastman

Department of Orthopaedic Surgery, University of Texas Health Science Center at Houston, Houston, TX

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
JEJonathan G. Eastman
Jonathan G. Eastman
MRMilton L. Chip Routt
Milton L. Chip Routt
Summary: The superior ramus is an irregularly shaped, undulating, and curvilinear osseous structure that can provide an osseous conduit for intramedullary screws. A wide spectrum of variability between the curve and obliquity of the superior ramus osseous fixation pathway (OFP) exists in both the anteroposterior and the coronal planes. A detailed understanding of the osseous topography and how it correlates with fluoroscopic imaging is mandatory. Obtaining the correct intraoperative inlet and combined obturator oblique–outlet fluoroscopic views specific to each patient's anatomy is necessary for safe implant insertion. Intramedullary screws can be inserted in either an antegrade or a retrograde direction depending on a number of variables, including fracture location, the proximity of patient's external genitalia to the skin insertion side, and the possible impact of thigh girth on the surgeons hand position. Multiple screw insertion techniques are possible, but a simple and reproducible technique is described. The size and number of screws that can be inserted is variable, differs between surgeons, but is ultimately dependent on the cortical limits of the superior ramus OFP. Standard screw insertion techniques are successful in most patients. If the osseous corridor or external anatomy impedes standard insertional techniques, several modifications exist that can allow successful screw insertion. A thorough understanding of each patient's anatomy, injury, and precise surgical technique with the appropriate fluoroscopic views are required to safely place intraosseous intramedullary implants into the superior ramus OFP.

24 October 2023 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Open access
PDF file
ASAugustine Saiz
Augustine Saiz
PKPatrick J. Kellam
Patrick J. Kellam
AAAdeet Amin
Adeet Amin
ZAZachary Arambula
Zachary Arambula
ARAbhi Rashiwala
Abhi Rashiwala
JEJonathan G. Eastman
Jonathan G. Eastman
Purpose: To describe U-type sacral fracture characteristics amenable to percutaneous sacral screw fixation. Methods: U-type sacral fractures were identified from a trauma registry at a level 1 trauma center from 2014 to 2020. Patient demographics, injury mechanism, fracture characteristics, and fixation construct were retrospectively retrieved. Associations between fracture pattern and surgical fixation were identified. Results: 82 U-type sacral fractures were reviewed. Six treated with lumbopelvic fixation (LPF) and 76 were treated with percutaneous sacral screws (PSS) alone. Patients receiving LBF had greater sacral fracture displacement in coronal, sagittal, and axial planes compared to patients receiving PSS alone (P < 0.05), negating osseous fixation pathways. All patients went onto sacral union and there were no implant failures or unplanned reoperations for either group. Conclusion: If osseous fixation pathways are present, U-type sacral fractures can be successfully treated with percutaneous sacral screws. LPF may be indicated in more displaced fractures with loss of spinopelvic alignment. Both techniques for U-type sacral fractures result in reliable fixation and healing without reoperations.

12 July 2023 in Journal of the American Academy of Orthopaedic Surgeons
Verified
Journal Article
Closed access
JEJonathan G. Eastman
Jonathan G. Eastman
SWStephen J. Warner
Stephen J. Warner
ASAugustine M. Saiz
Augustine M. Saiz
DBDaniel A. Bravin
Daniel A. Bravin
MRMilton L. Chip Routt
Milton L. Chip Routt
Pelvic ring injuries and acetabular fractures can be complex and challenging to treat. Orthopaedic trauma surgeons scrutinize pelvic radiographs and accompanying CT images for the osseous details that help create a thorough patient-specific preoperative plan. While the osseous details are incredibly important, the surrounding soft-tissue structures are equally as critical and can have a tremendous effect on both the patient and the surgeon. These findings may change surgery timing, dictate the need for additional surgeons or multidisciplinary teams, and determine the treatment sequence. The structures and potential clinical findings reviewed and demonstrated through example images should be sought out during physical examination and correlative preoperative imaging review. Combining all the available osseous and nonosseous information with a detailed approach helps the surgeon predict potential pitfalls and adjust surgical plans before incision. Maximizing the accuracy of the preoperative planning process can streamline treatment algorithm development and ultimately contribute to the best possible clinical patient outcome.

1 November 2023 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
SWStephen J. Warner
Stephen J. Warner
DHDouglas R. Haase
Douglas R. Haase
MRMilton L. Chip Routt
Milton L. Chip Routt
JEJonathan G. Eastman
Jonathan G. Eastman
TATimothy S. Achor
Timothy S. Achor
Summary: Multidimensional fluoroscopy has been increasingly used in orthopaedic trauma to improve the intraoperative assessment of articular reductions and implant placement. Owing to the complex osteology of the pelvis, cross-sectional imaging is imperative for accurate evaluation of pelvic ring and acetabular injuries both preoperatively and intraoperatively. The continued development of fluoroscopic technology over the past decade has resulted in improved ease of intraoperative multidimensional fluoroscopy use in pelvic and acetabular surgery. This has provided orthopaedic trauma surgeons with a valuable tool to better evaluate reduction and fixation at different stages during operative treatment of these injuries. Specifically, intraoperative 3D fluoroscopy during treatment of acetabulum and pelvis injuries assists with guiding intraoperative decisions, assessing reductions, ensuring implant safety, and confirming appropriate fixation. We outline the useful aspects of this technology during pelvic and acetabular surgery and report its utility with a consecutive case series at a single institution. The added benefits of this technology have improved the ability to effectively manage patients with pelvis and acetabulum injuries.

5 July 2021 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Closed access
PDF file
JEJonathan G. Eastman
Jonathan G. Eastman
QKQuintin A. Kuse
Quintin A. Kuse
MRMilton L. Chip Routt
Milton L. Chip Routt
TSTrevor J. Shelton
Trevor J. Shelton
MAMark R. Adams
Mark R. Adams

4 October 2017 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
JEJonathan Eastman
Jonathan Eastman
BDBradley Deafenbaugh
Bradley Deafenbaugh
BCBlaine Christiansen
Blaine Christiansen
TGTanya Garcia‐Nolen
Tanya Garcia‐Nolen
MLMark Lee
Mark Lee