12 January 2018 in IEEE Transactions on Power Systems
Successful transition to active distribution networks (ADNs) requires a planning methodology that includes an accurate network model and accounts for the major sources of uncertainty. Considering these two essential features, this paper proposes a novel model for the multistage distribution expansion planning (MDEP) problem, which is able to jointly expand both the network assets (feeders and substations) and renewable/conventional distributed generators (DGs). With respect to network characteristics, the proposed planning model employs a convex conic quadratic format of AC power flow equations that is linearized using a highly accurate polyhedral-based linearization method. Furthermore, a chance-constrained programming (CCP) approach is utilized to deal with the uncertain renewables and loads. In this regard, as the probability distribution functions (PDFs) of uncertain parameters are not perfectly known, a distributionally robust (DR) reformulation is proposed for the chance constraints (CCs) that guarantees the robustness of the expansion plans against all uncertainty distributions defined within a moment-based ambiguity set. Effective linearization techniques are also devised to eliminate the nonlinearities of the proposed DR reformulation, which yields a distributionally robust chance-constrained mixed-integer linear programming (DRCC-MILP) model for the MDEP problem of ADNs. Finally, the 24-node and 138-node test systems are used to demonstrate the effectiveness of the proposed planning methodology.
16 February 2017 in IEEE Transactions on Power Systems
This paper presents a linear-quadratic regulator (LQR) for damping of subsynchronous interaction (SSI) in doubly-fed induction generator (DFIG)-based wind farms. The proposed LQR controller employs a full-state observer to estimate all state variables. The output of the LQR is added to control signals of inner current control loops of DFIG converters as supplementary control signals. The supplementary control signals are dynamically limited to avoid saturating the converters and to provide the DFIG with the desired transient response against power system faults. The proposed SSI damping controller is designed for a realistic series compensated wind farm, and its performance is verified using electromagnetic transient (EMT) simulations. The EMT simulations are performed using a detailed DFIG model which includes all nonlinearities and all required transient functions to meet the grid code requirements corresponding to fault-ride-through (FRT). The results show that the proposed SSI controller is able to significantly mitigate the oscillations due to the SSI phenomenon, and to provide excellent transient response against systems faults.
25 January 2022 in IEEE Transactions on Industry Applications
SSShah Mohammad Rezwanul Haque Shawon
Shah Mohammad Rezwanul Haque Shawon
Due to the increasing penetration of renewable energy sources, microgrids with the self-adequacy feature becomes a promising platform in distribution systems to interconnect geographically closed distributed generation units and load. Micogrids enable faster service restoration during disturbances and natural disasters, and offer improved system reliability. In this article, an extensive literature review is conducted by focusing on several important aspects of the distribution network modernization: planning and service restoration using microgrid formation and soft open points (SOPs) to achieve the improved system performance. The SOP is an emerging power electronic device in distribution systems by connecting feeders or networked microgrids to realize voltage regulation and service restoration. The future research directions in these important areas are recommended in the article.
22 April 2020 in IEEE Transactions on Power Systems
This paper proposes a methodology for predicting online rotor angle stability in power system operation under significant contribution from wind generation. First, a novel algorithm is developed to extract a stability index ( SI ) that quantifies the margin of rotor angle stability of power systems reflecting the dynamics of wind power. An approach is proposed that takes advantage of the machine learning technique and the newly defined SI . In case of a contingency, the developed algorithm is employed in parallel to find SI s for all possible instability modes. The SI s are formed as a vector and then applied to a classifier algorithm for rotor angle stability prediction. Compared to other features used in state-of-the-art methods, SI vectors are highly recognizable and thus can lead to a more accurate and reliable prediction. The proposed approach is validated on two IEEE test systems with various wind power penetration levels and compared to existing methods, followed by a discussion of results.
24 August 2017 in IEEE Transactions on Power Delivery
This paper proposes a novel scheme to mitigate DG effects on existing fuse-recloser protection in radial distribution networks. The proposed scheme employs a control unit, variable load bank and dedicated recloser at the point of common coupling (PCC). It detects the increase in the DG terminal current producing a tripping signal when it exceeds a preset value. It also receives a fault detection signal from the head-end recloser via a fast communication channel; hence disconnects the DG unit from the system and connects a transfer impedance at the PCC to operate the DG unit at its pre-fault load sharing condition. This allows the DG unit to maintain operation at the pre-fault level with no need for immediate shut down. As a result, faster reconnection of the DG unit to the system is guaranteed after successful reclosing. The transfer impedance is selected from a variable load-bank and is a function of the pre-fault load sharing condition; therefore, a sensitivity survey was performed to cover all possible system operating conditions and its corresponding transfer impedances. Multiple in-depth time domain simulations are conducted to ascertain the efficiency of the proposed scheme in mitigating the impact of DG sources on existing overcurrent protection infrastructure. Time domain simulations have been conducted using a typical distribution network in the EMTP-RV software environment for validation purposes.
13 November 2023 in IEEE Transactions on Industry Applications
The soft open point (SOP) is an emerging power electronics device in place of normally open points/tie switches in distribution systems. During a fault, service restoration can be effectively achieved by coordinating SOPs and distributed generation units (DGs). In this paper, a novel two-stage SOP-based service restoration method in distribution networks is proposed: In Stage 1, a dynamic load-shedding scheme is prepared/applied during a fault occurred at the upstream grid, and the power supply to priority loads is maintained through DGs; in Stage 2, DGs, SOPs and switches are coordinated and operated to realize restoration in the outage area with controllable/dispatchable distributed generation units (CDGs) dispatched to their maximum capacity limits. In both stages, real and reactive power of SOPs is regulated to maximize load restoration. A mixed-integer nonlinear programming (MINLP) model through AC power flow is developed to formulate the restoration problem mathematically. The modified IEEE 33-node test system is used to validate the proposed restoration method combined with centralized or decentralized optimization. The proposed method is also compared with an existing method, showing much improved restoration performance.