19 February 2019 in BioMed Research International
Introduction. Nonunions are a challenge for orthopedic surgeons. In hypertrophic nonunions, improvement of mechanical stability usually is the satisfactory treatment, whereas in atrophic nonunions improvement of the biological environment is most important. However, scientific evidence revealed that “avital” nonunions are not avascular and fibrous tissue contains cells with osteogenic potential. To find out if systemic factors suppress this intrinsic potential in atrophic nonunions, this study compares characteristics of hypertrophic with atrophic nonunion patients. Methods. We analyzed medical records of 162 surgically treated patients suffering from aseptic long bone nonunions. Atrophic and hypertrophic nonunions were distinguished by absence or presence of callus and calcification in the fracture gap. Mechanical implant loosening and patient characteristics such as age, gender, and body mass index were assessed. Fracture classification according to AO/OTA, open and closed fractures, and osteosynthesis were recorded. In addition, comorbidities and allergies between both groups were compared. Results. A higher number of hypertrophic nonunion patients were male with often allergies. Hypertrophic nonunion occurred more often after intramedullary nailing compared to atrophic nonunions. Atrophic nonunion patients being nonallergic were significantly older than nonallergic patients suffering from hypertrophic nonunions. In both atrophic and hypertrophic nonunion patients, age was lower in patients with accompanying injuries compared with age of patients with isolated fractures. Conclusion. Systemic factors influence development of nonunion types. In nonallergic patients, atrophic nonunions occur more often in the elderly. This manuscript is a first step to identify different factors which might influence the nature of nonunion. To enable nonunion treatment which is tailored to individual patient characteristics, further prospective studies with more sophisticated research methods are necessary.
1 August 2017 in The American Journal of Pathology
3 July 2020 in European Journal of Orthopaedic Surgery & Traumatology
Background and aims: Rheumatoid arthritis is a chronic inflammatory disease. The associated involvement of hands and tendons is over 90% and impairs overall function. In the course of the disease, the joints are often operated on. During this operation, ruptures of the extensor tendons are found by chance without the patients noticing them. The aim of this retrospective study is the prevalence of extensor tendon rupture. Which tendon is destroyed most frequently? How can the functional outcome be measured after reconstruction? Materials and methods: From 1572 operations on rheumatoid wrists, 61 extensor tendon ruptures were identified in 41 patients. The average time between the first rheumatic symptoms of the hand and surgery was 6.4 years. The average duration of RA was 7.8 years. 26 patients with 27 tendon reconstructions were included in the follow-up with an average postoperative duration of 4.6 years (3 to 14.2 years). Results: Extensor tendons ruptures typically occurred at mechanically stressed sites. The most frequent rupture was found in the extensor pollicis longus tendon (21 tendons), followed by the small finger extensor tendon (14 tendons). A transfer was performed on 7 tendons. Fifty-five tendon lesions were sutured at other intact tendons. Free grafts were not used. The results in Clayton and QuickDASH scores were significantly different. Functional improvement was consistent with the results of tendon reconstructions in healthy control groups. Conclusion: In rheumatoid patients, a rupture of an extensor tendon must be expected at 4%. Patients tolerate and compensate this damage for a long time. The function of the hand including the tendon function is the most important factor in assessing the success of the operation. The subjective patient acceptance depends on the progress of the underlying disease, postoperative care (ergotherapy, physiotherapy, orthosis) and the patients' demands.
16 March 2021 in Journal of Materials Chemistry C
Cs incorporation into perovskite filmviaa thin Cs2CO3layer ETL passivation treatment.
6 June 2017 in Journal of Bone and Mineral Metabolism
29 May 2019 in BMC Musculoskeletal Disorders
Periprosthetic fractures (PPF) present a common cause for revision surgery after arthroplasty. The choice of performing either an osteosynthesis or revision arthroplasty depends on the orthopedic implant anchored and loosening. Standard diagnostics include x-ray imaging. CT is usually performed to confirm implant loosening in case of ambiguous diagnosis on standard x-ray imaging. This study aimed to examine the role of CT as a diagnostic modality and its implications for treatment planning and outcome. Patients treated for PPF from January 2010 to February 2018 were included. X-ray and CT reports were analyzed to assess implant loosening. The planning for surgery and the final surgical treatment were evaluated. In addition, patient characteristics were analyzed and compared between patients with and without additional CT as a preoperative diagnostic procedure. Seventy-five patients were eligible for the study. X-ray imaging was performed in 90.7% of cases. CT was performed in 60% of the cases as part of the preoperative diagnostic. A clear statement on implant stability or loosening could not be made in 69.1% after X-ray imaging and in 84.4% following CT imaging. Revision arthroplasty for loosened femoral prosthesis components was necessary in 40% of cases. No difference could be determined comparing patients with X-ray imaging to those with X-ray and additional CT. In both groups, operative treatment did not deviate from the preoperative planning. In two thirds of the conventional radiographic findings, no reliable evaluation of implant loosening was possible in femoral PPFs. Intriguingly, additional CT did not improve the evaluation of implant loosening. Nonetheless, CT scans are often performed if loosening assessment is unclear on regular radiographs. This fact can explain the bias CT results in comparison to regular radiography. However, software-supported CT diagnosis could help to adequately answer the question of loosened implants in PPF in the near future. Since the diagnosis of fracture and their morphology assessment is currently adequately performed using X-rays, CT shall not be considered as the gold standard.