30 November 2020 in NAUCHNOE PRIBOROSTROENIE
Several decades have passed since the development of the revolutionary DNA sequencing method by Frederick Sanger and his colleagues. After the Human Genome Project, the time interval between sequencing technologies began to shrink, while the volume of scientific knowledge continued to grow exponentially. Following Sanger sequencing, considered as the first generation, new generations of DNA sequencing were consistently introduced into practice. Advances in next generation sequencing (NGS) technologies have contributed significantly to this trend by reducing costs and generating massive sequencing data. To date, there are three generations of sequencing technologies. Second generation se-quencing, which is currently the most commonly used NGS technology, consists of library preparation, amplification and sequencing steps, while in third generation sequencing, individual nucleic acids are sequenced directly to avoid bias and have higher throughput. The development of new generations of sequencing has made it possible to overcome the limitations of traditional DNA sequencing methods and has found application in a wide range of projects in molecular biology. On the other hand, with the development of next generation technologies, many technical problems arise that need to be deeply analyzed and solved. Each generation and sequencing platform, due to its methodological approach, has specific advantages and disadvantages that determine suitability for certain applications. Thus, the assessment of these characteristics, limitations and potential applications helps to shape the directions for further research on sequencing technologies.
30 November 2020 in NAUCHNOE PRIBOROSTROENIE
R(Russia St. Petersburg Clinical Scientific And Practical Center For Specialized Types Of Medical Care (Oncological)
Russia St. Petersburg Clinical Scientific And Practical Center For Specialized Types Of Medical Care (Oncological)
+2
The method is proposed for express diagnostics of diseases according to the data of mass spectrometric analysis of exhaled air. An algorithm for calculating the probability of diseases has been developed and tested. The results of data processing of patients treated in two oncological clinics are presented. The calculation of the probability of disease according to the data of mass spectrometric analysis of exhaled air is based on attributing the mass spectrum of the tested patient to the mass-spectra of the corresponding control group. Each control group is formed by collecting an array of spectra from at least ten patients with the same disease. Diagnostics is performed by transforming the matrix of spectra of the control group and the spectrum of a patient being tested into the space of the principal components. The probability of a disease is determined by the Euclidean distance of the patient's coordinates from the centroid of the control group in the multidimensional space of these principal components.
30 November 2020 in NAUCHNOE PRIBOROSTROENIE
The effect of the gas flow to the ion transport from the atmosphere to the forevacuum region of the is determined experimentally. Experimental volt-ampere characteristics of the ion flow carried by the gas-dynamic flow behind the nozzle are obtained. It is shown that the fraction of the ion current passing through the nozzle under the influence of the gas flow can be increased several times in relation to the current value due only to the extraction by the electric field. In this case, depending on the magnitude of the electric field penetrating beyond the skimmer, the current is redistributed between the nozzle and the collector. It was found that, under the experimental conditions, the entire ion flux reaches the movable collector at a distance of up to 15 mm at a field strength of 200 V / cm. The diameter of the ionic component of the flow is 1.5 mm. The ion motion in a gas is simulated for conditions close to the experimental ones. Developing research findings, it is possible to consider systems for transporting ions further to the analyzer.
30 November 2020 in NAUCHNOE PRIBOROSTROENIE
Ammonia-sensitive materials based on tin dioxide have been developed and synthesized. The degree of structural defects was evaluated, and the acid-base surface centers of synthesized materials were studied using the indicator method. The relationship between the chemisorption properties of synthesized gas-sensitive sensor layers (gas response to the concentration effect of ammonia) and the structure of the sensor material is discovered and analyzed. The novelty of the research is the integrated approach presented in this paper to the creation, development and manufacture of sensors for ammonia by synthesizing a material with pre-set properties using several methods of surface modernization simultaneously.