10 December 2015 in Indoor and Built Environment
This study aims to investigate the natural lighting performance in indoor and semi-open spaces of urban vernacular architecture in the Mediterranean region. In vernacular architecture, natural lighting was the main source of light available and was largely achieved through the central courtyard. In this framework, an in-depth lighting performance analysis was carried out in a typical and representative traditional urban complex in the walled city of Nicosia, Cyprus. In-situ lighting measurements, as well as software simulations, were employed in order to assess the lighting performance of the building complex. The study has shown that lighting levels of semi-open and indoor spaces on the first floor are sufficient; whereas, the dense urban fabric, and the introverted character of vernacular architecture, create certain limitations to the lighting levels in indoor spaces of the ground floor. On the other hand, the positive impact of the inner courtyard to the lighting levels of semi-open and indoor spaces has been verified.
3 May 2023 in Building Research & Information
The architectural engineering and construction sector accounts for about 30-40% of global energy consumption. The European goal of reducing this consumption and the linked greenhouse gas emissions calls for an increased capacity to implement building renovations. Building Information Modelling (BIM) and Building Performance Simulations (BPS) are among the most promising tools for fostering interdisciplinary, efficient processes and feasible analysis and design solutions to support this goal. Of the whole building stock, heritage buildings represent the most challenging part, although their potential as a driver for mitigating climate change and supporting sustainable development is being increasingly recognized. This paper presents a Heritage BIM and BPS-based workflow to support the energy and environmental improvement of publicly-owned historical buildings, that was applied to 9 case studies of 7 different Mediterranean countries. The overall aim of this research is to enhance the capacity of public local administrations and professionals to upgrade the historical building stock and demonstrate the scalability of the proposed workflow to the entire building stock of the Mediterranean area.
14 March 2017 in Indoor and Built Environment
This paper investigates the overall thermal performance of vernacular buildings in Nicosia, Cyprus and highlights the role of semi-open spaces in improving the thermal comfort of the aforementioned structures. The novelty of the study lies in the fact that it presents, in a comparative way, field measurements carried out in five traditional buildings, discussing at the same time the impact of authentic architectural features, as well as of contemporary interventions, on the bioclimatic function of the original building envelope, taking into account the daily use of the premises under investigation. The research outcomes highlight the positive contribution of semi-open spaces to the thermal comfort of vernacular buildings, especially during the cooling period (summer). Contemporary architectural interventions, such as the conversion of semi-open spaces into closed indoor spaces, as well as the behaviour of occupants, are also found to affect the thermal performance of the traditional building envelope.
4 June 2024 in Energy Efficiency
MAMargarita-Niki Assimakopoulos
Margarita-Niki Assimakopoulos
+11
The Eastern Mediterranean and Middle East (EMME) region hosts some of the world’s most influential and troubled cities. It is also a hotspot of climate change and socio-economic and political turbulence, which inflate the already flammable conditions and reinforce existing local vulnerabilities. Some of the most arduous challenges of cities relate to the built environment – although vital for human well-being, buildings rarely offer both sufficient and affordable shelter to their inhabitants. With energy performance regulations coming into effect during the past three decades, a considerable proportion of the worldwide building stock had already been constructed and is now ageing and inefficient. Harmonising the energy performance of buildings at a sufficient level requires common objectives and priorities, and the EMME region consists of nations with different governance and regulations. Scarce literature exists on the existing operational frameworks, and this study aims to offer an overview of the built environment policy scene in the EMME region, identifying gaps, good practices and prospects. The study draws from scholarly literature, national and international regulations and other document sources, as well as local experts. This work finds that although most EMME countries participate in and embrace international agreements, they act individually and not collectively, confirming our hypothesis that the policy agenda reflects the diverse characteristics of the region. By recognising standing failings and strengths, moving forward becomes a possibility through the adoption of integrated governance, common policy agendas and financing mechanisms to create sustainable urban centres inhabited by resilient and equitable communities.
2 January 2018 in Journal of Architectural Conservation
The present paper correlates aspects of built heritage conservation, occupant’s behaviour and thermal comfort. The research focuses on the contemporary architectural intervention of converting original semi-open spaces, that have been acting as such during all periods of the year, into indoor spaces by adding movable glass dividers. A representative building that reflects the typical arrangement of rural vernacular earth architecture in Cyprus is selected for detailed investigation. In situ measurements and simulation tools are used to investigate the adjustment of airflow through the operation of windows when the dividers are open (heating period) and closed (cooling period). Computational Fluid Dynamics are employed in order to illustrate the temperature distribution of various window operation patterns that are evaluated according to the adaptive thermal comfort. The results argue on the climatic adaptability of vernacular buildings and indicate that the examined window control patterns have a more prominent impact during the heating period. Conclusions confirm the cooling potential of night ventilation and highlight the benefit of having energy-aware and engaged occupants. Key directions regarding conservation practices and occupant’s behaviour are brought forth, bringing energy efficiency and comfort into the discussion about cultural heritage.
6 June 2022 in Renewable Energy and Environmental Sustainability
Safeguarding affordable and energy-efficient medical services has emerged as a crucial necessity to sustain national healthcare systems, especially in view of the current pandemic. While a set of national standards and guidelines aim to set minimum energy requirements for the building facilities, more insight into the healthcare sector’s energy consumption in Cyprus is deemed necessary, since it is the 4th most energy-demanding sector per square meter in this country. This is the first extended research on energy consumption in healthcare facilities across the different climatic zones of Cyprus and the types of fuel favoured in each zone, which marks the novelty of this work. The findings of the study highlight that the coastal and inland climatic zones are the most energy-challenging regions, with more than 60% of the final energy needs covered by electricity. On the contrary, in the mountainous region, approximately 80% of the final energy needs are covered by oil and attributed mainly to heating purposes. The average national primary energy consumption of healthcare facilities was found to be 497 kWh/m2 in air-conditioned spaces. Therefore, this study highlights that the mean primary energy consumption per building surface is approximately 4 times higher than the national threshold for nZEBs; compelling critical consideration of intervention for their energy enhancement. Moreover, healthcare facilities in mountainous regions in Cyprus are heavily reliant on conventional fuel; an unreliable and highly polluting energy option. The work demonstrates the prominent challenge and high potential for energy retrofit of the examined facilities and their upgrading to nZEB-Hospitals, towards the endeavour to a climate-neutral energy transition.