T. M. Ruzmatov

T. M. Ruzmatov

Auto-generated profile, based on publicly available information

T. M. Ruzmatov

School of Biomedical Engineering University of Technology Sydney New South Wales Australia

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Pirogov Russian Journal of Surgery
Verified
Journal Article
Closed access
ACA. M. Chernyavsky
A. M. Chernyavsky
ATA. R. Tarkova
A. R. Tarkova
TRT. M. Ruzmatov
T. M. Ruzmatov
SMS. V. Morozov
S. V. Morozov
IGI. A. Grigoriev
I. A. Grigoriev

17 November 2016 in Russian Journal of Transplantology and Artificial Organs
Verified
Journal Article
Open access
PDF file
ACA. M. Chernyavskiy
A. M. Chernyavskiy
AFA. V. Fomichev
A. V. Fomichev
TRT. M. Ruzmatov
T. M. Ruzmatov
AМArray Е. Медведев
Array Е. Медведев
YPYu. M. Prikhodko
Yu. M. Prikhodko
VCV. P. Chekhov
V. P. Chekhov
Актуальность использования систем вспомогательного кровообращения в лечении хронической сердечной недостаточности постоянно возрастает, поскольку 20% пациентов из листа ожидания ежегодно погибают, не дождавшись донорского сердца. Несмотря на огромную потребность в системах механической поддержки сердца в клиниках страны, приобретение зарубежных аналогов связано с определенными сложностями, т. к. их стоимость слишком высока для широкого применения. Кроме того, на сегодняшний день не существует ни одной системы, которая на 100% отвечала бы всем медико-техническим требованиям и была бы полностью безопасна для пациента. Поэтому отечественные исследования в области разработки и внедрения систем вспомогательного кровообращения (ВК), доступных для широкого использования и отвечающих медико-техническим требованиям, являются актуальными и востребованными. Одним из новых направлений в исследовании являются системы механической поддержки кровообращения на основе дисковых насосов вязкого трения для транспортировки жидких сред, основанные на принципе работы насоса Тесла. Принцип действия насосов основан на явлении пограничного слоя, который образуется на диске, вращающемся в жидкости. Проводятся экспериментальные исследования моделей с различными вариантами подвеса ротора, различными формами и количеством дисков, формами корпусов насоса. Однако ни один из описанных образцов не был доведен до клинических испытаний. Кроме того, несмотря на перспективность этой модели, до сих пор в ряде современных используемых систем вспомогательного кровообращения нет ни одного насоса подобного типа. Опубликованные данные дают основания для дальнейшей разработки и испытания этой модели насоса и позволяют надеяться на нивелирование ряда значимых недостатков современных систем обхода левого желудочка.

1 January 2015 in Pirogov Russian Journal of Surgery
Verified
Journal Article
Closed access
TRT. M. Ruzmatov
T. M. Ruzmatov
VÉV. U. Éfendiev
V. U. Éfendiev
ABA. V. Boboshko
A. V. Boboshko
EME. S. Malakhov
E. S. Malakhov
ANA. S. Nesmachnyĭ
A. S. Nesmachnyĭ
ACA. M. Cherniavskiĭ
A. M. Cherniavskiĭ
To estimate the results of sternomediastinitis management using vacuum-therapy compared with conventional treatment of such wounds.

1 January 2015 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
VEV. U. Efendiev
V. U. Efendiev
SAS. A. Alsov
S. A. Alsov
TRT. M. Ruzmatov
T. M. Ruzmatov
IMI. L. Mikheenko
I. L. Mikheenko
ACA. M. Chernyavsky
A. M. Chernyavsky
EME. S. Malakhov
E. S. Malakhov
A new technology – a thoracoscopic coronary bypass grafting with the use of Da Vinci robotic system in Russia is represented by the experience of NRICP. The technology was introduced in Russia in 2011. Overall, one hundred endoscopic coronary artery bypass procedures were performed. We have compared and analyzed results of coronary artery stenting vs minimally invasive coronary artery bypass grafting. According to the results, totally endoscopic coronary artery bypass grafting has several advantages over alternative treatment strategies.

11 July 2020 in Journal of Cardiac Surgery
Verified
Journal Article
Open access
PDF file
АCАлександр Михайлович Chernyavskiy
Александр Михайлович Chernyavskiy
AFAlexey Fomichev
Alexey Fomichev
TRTimur Ruzmatov
Timur Ruzmatov
AKAlexander Khaustov
Alexander Khaustov
Background The use of dual continuous‐flow assist devices for biventricular support remains novel with only small case series or reports documenting outcomes. Methods We describe a 21‐year‐old woman suffered stabbing with damage of coronary artery with subsequent myocardial infarction and severe postinfarction heart failure with impaired right ventricular function. The patient underwent implantation of two continuous‐flow ventricular assist devices. Results The early postoperative period was followed by severe respiratory insufficiency and an asthenic syndrome, which required prolonged intensive care and mechanical ventilation. After prolonged hospital stay, she was discharged home waiting for heart transplantation. Conclusions With the continuing miniaturization of pump designs, less invasive, more durable and cost‐effective pumps have become available for dual assist device therapy in in these critically ill heart failure patients.

14 April 2017 in Russian Journal of Transplantology and Artificial Organs
Verified
Journal Article
Open access
PDF file
ACA. M. Chernyavskiy
A. M. Chernyavskiy
TRT. M. Ruzmatov
T. M. Ruzmatov
AFA. V. Fomichev
A. V. Fomichev
AМArray Е. Медведев
Array Е. Медведев
YPYu. M. Prikhodko
Yu. M. Prikhodko
AКArray М. Караськов
Array М. Караськов
Цель: экспериментальная оценка производительности дискового насоса вязкого трения, изучение взаимосвязи междискового зазора и размеров входных и выходных отверстий и параметров производительности насоса. Материалы и методы. Для изучения характеристик и оптимизации конструкции дискового насоса трения, предназначенного для перекачивания крови, был изготовлен макет насоса и стенд для его испытания. Габариты насоса задавались, исходя из медико-биологических требований для систем механической поддержки сердца и с учетом экспериментальных исследований наших коллег из Пенсильвании. Объемный расход рабочей жидкости измерялся поплавковым ротаметром Krohne VA-40 c погрешностью измерений не более 1%. Значения давления в гидродинамическом контуре измерялись при помощи монитора производства фирмы «Биософт-М». Дросселирующее устройство позволяло менять гидравлическое сопротивление системы, имитируя общее периферическое сопротивление сердечно-сосудистой системы человека. Результаты. В ходе эксперимента получена линейная прямая зависимость между производительностью насоса и создаваемым им перепадом давления жидкости на входе и выходе на насосе. Требуемые значения расхода (5–7 л/мин) и давления (90–100 мм рт. ст.) достигаются при частоте вращения ротора в диапазоне 2500–3000 об/мин. Показано, что увеличение входного диаметра до 15 мм не привело к значимому увеличению производительности насоса, а наибольшие значения производительности можно получить для величины междискового зазора 0,4–0,5 мм. Заключение. Спроектированный и изготовленный экспериментальный макет дискового насоса для перекачивания жидкости показал принципиальную возможность использовать такую модель в качестве системы для механической поддержки сердца.