Alexander Khaustov

Alexander Khaustov

Auto-generated profile, based on publicly available information

Alexander Khaustov

Moscow Aviation Institute (National Research University)

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Russian Engineering Research
Verified
Journal Article
Closed access
PDF file
ABA. E. Belyavskii
A. E. Belyavskii
ASA. E. Sorokin
A. E. Sorokin
AKA. I. Khaustov
A. I. Khaustov
The windshield projection of information (head-up display, HUD) is shown to be suitable for use in aviation. The design of projection systems is considered

11 July 2020 in Journal of Cardiac Surgery
Verified
Journal Article
Open access
PDF file
АCАлександр Михайлович Chernyavskiy
Александр Михайлович Chernyavskiy
AFAlexey Fomichev
Alexey Fomichev
TRTimur Ruzmatov
Timur Ruzmatov
AKAlexander Khaustov
Alexander Khaustov
Background The use of dual continuous‐flow assist devices for biventricular support remains novel with only small case series or reports documenting outcomes. Methods We describe a 21‐year‐old woman suffered stabbing with damage of coronary artery with subsequent myocardial infarction and severe postinfarction heart failure with impaired right ventricular function. The patient underwent implantation of two continuous‐flow ventricular assist devices. Results The early postoperative period was followed by severe respiratory insufficiency and an asthenic syndrome, which required prolonged intensive care and mechanical ventilation. After prolonged hospital stay, she was discharged home waiting for heart transplantation. Conclusions With the continuing miniaturization of pump designs, less invasive, more durable and cost‐effective pumps have become available for dual assist device therapy in in these critically ill heart failure patients.

1 September 2021 in Herald of the Bauman Moscow State Technical University. Series Mechanical Engineering
Verified
Journal Article
Closed access
AKA.I. Khaustov
A.I. Khaustov
GBG.G. Boyarskiy
G.G. Boyarskiy
The paper presents the results of developing a micro-pump for the circulatory support system. The maximum diameter of the micropump is 6.5 mm. This allows it to be introduced into the human body through the femoral artery, which ensures its minimally invasive use. The micropump draws blood from the left ventricle of the heart and pumps it into the aorta behind the aortic valve. The numerical analysis of the spatial flow of an incompressible viscous fluid (blood) in the developed elements of the micropump allowed us to prove that its flow path corresponds to the conditions of minimal hemolysis and thrombosis during blood pumping. The developed micropump ensures uniform distribution of pressure and blood flow velocity at the outlet, which guarantees a uniform blood supply to the aorta. There are no zones of stagnation of blood and vortices throughout the flow part of the micropump, which reduces thrombosis in the micropump. In the entire volume of blood flow, even in the peripheral section of the micropump impeller, shear rates and shear stresses do not exceed critical values, which leads to minimal blood hemolysis in the developed elements of the micropump. The obtained results of 3D flow simulation in the elements of the micropump made it possible to develop design documentation for the manufacture and testing of its prototype on hydraulic and hemodynamic stands

28 November 2022 in Journal of the Russian Universities. Radioelectronics
Verified
Journal Article
Open access
PDF file
AKA. I. Khaustov
A. I. Khaustov
GBG. G. Boyarsky
G. G. Boyarsky
KKK. V. Krotov
K. V. Krotov
Introduction. Support systems currently used in modern cardiac surgery to provide partial or complete, permanent or temporary replacement of cardiac function are frequently characterized by large dimensions, thus requiring major surgical interventions. Low invasiveness can be ensured by reducing the size of the implanted part of such systems, allowing these devices to be inserted through the femoral artery.Aim. Development of a minimally invasive micropump system to support blood circulation.Materials and methods. Based on the analysis of implementation of micropump circulatory support systems (MCSS), the configuration, operational principles and main components of such a system were determined. When designing a micropump, as a unit defining the weight and size parameters of the entire system, numerical and experimental methods were used to optimize its flow path based on the condition of minimizing blood injury and thrombus formation. The lubrication and cooling system was developed by solving the thermodynamic problem of heat removal. The electronic control unit was developed on the basis of accumulated experience in the design and operation of control units for circulatory support systems.Results. A micropump with a diameter of 6.5 mm and a length of 43 mm with the required hydro- and hemodynamic parameters was designed. The device ensures minimal trauma and thrombus formation. The main MCSS parameters, as well as its main components (electric drives, lubrication and cooling systems), were defined. The configuration and operational principles of the electronic control unit (ECU), consisting in a microprocessor-based control system with feedback, were developed. The ECU built-in software manages the rotational speed of the electric drives of the micropump and coolant supply pump in the required range. In addition, the software is used to measure, display and register the MCSS operational parameters, as well as to monitor their operation in the required ranges and to exchange data between the ECU and the PC.Conclusion. All the necessary documentation for the MCSS nodes and components was prepared. These nodes and components ensure the hydro- and hemodynamic parameters required for the use of the developed minimally invasive micropump system. Future work will address the stages of MCSS assembly and debugging.

7 May 2026 in Proceedings of the Southwest State University. Series: IT Management, Computer Science, Computer Engineering. Medical Equipment Engineering
Verified
Journal Article
Open access
PDF file
KKK. V. Krotov
K. V. Krotov
GBG. G. Boyarsky
G. G. Boyarsky
AKA. I. Khaustov
A. I. Khaustov
Purpose of research . The object of the article is to determine the influence of the assisted blood circulation pumps geometry on the head-flow characteristic slope. Reasoning for the research consists of necessity in new blood circu lation assist pumps and demand for improving existing devices. Methods . To assess the effect of geometric parameters on the slope of the head-flow characteristics, a three-factor numerical experiment plan has been developed, consisting of 21 pumps with different geometric parameters. The factors were: the diameter of the sleeve d, the diameter of the periphery D, and the diagonal angle of the sleeve φ of the pump impeller. Numerical simulation of blood flow in pumps was performed using the finite volume method in the OpenFOAM11 calculation package. The SIMPLE method was used for the calculation, and the MRF technology was used to account for rotation. Results . As a result of the numerical experiment, relative head-flow characteristics for each pump were obtained, showing the influence of diameters D, d, and diagonality φ on the slope of the head-flow characteristic; these were approximated by a 3rd-degree polynomial using the least squares method. The obtained dependencies allow for de termining the pump rotation speed for any of its operating regimes. From the generalization of the results of numeri cal modeling of blood flow in the pumps, 3D-surfaces were obtained, representing a set of dependencies of the head flow characteristic slope on the geometric parameters of the pump flow path. Conclusion .. It was established that the required increase in head-flow characteristic slope can be achieved by changing the hub and shroud diameters and the angle of diagonality. The minimum slope is achieved at the average values of the numerical experiment factors. The maximum slope corresponds with minimum and maximum diameter values. The research results have a practical value for designing and improving axial pumps of the assisted blood circulation devices