Laurent Thiery

Laurent Thiery

Auto-generated profile, based on publicly available information

Laurent Thiery

FEMTO-ST Institute, UMR 6174, Université de Franche-Comté, CNRS, ENSMM, UTBM, Besançon 25030, France

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2008 in Journal of Heat Transfer
Verified
Journal Article
Closed access
PDF file
LTL. Thiery
L. Thiery
STS. Toullier
S. Toullier
DTD. Teyssieux
D. Teyssieux
DBD. Briand
D. Briand

1 November 2019 in Review of Scientific Instruments
Verified
Journal Article
Closed access
TNT. P. Nguyen
T. P. Nguyen
LTL. Thiery
L. Thiery
SESébastien Euphrasie
Sébastien Euphrasie
SGSéverine Gomès
Séverine Gomès
BHBruno Hay
Bruno Hay
PVP. Vairac
P. Vairac
We present a procedure dedicated to the calibration of a scanning thermal microscopy probe operated in an active mode and a modulated regime especially for the measurement of solid material thermal conductivities. The probe used is a microthermocouple wire mounted on a quartz tuning fork. Measurements on reference samples are performed successively in vacuum and ambient air conditions revealing a clear difference in the dependence of the thermal interaction between the probe and the sample on the sample properties. Analytical modeling based on the resolution of the heat equation in the wire probe and a description of the thermal interaction using a network of thermal conductances are used to fit experimental data and analyze this difference. We have experimentally verified that the effective thermal contact radius of the probe tip depends on the sample thermal conductivity in ambient conditions, whereas it remains constant in vacuum. We have defined the measurement range of the technique based on the decrease in the probe sensitivity at high thermal conductivities. Considering the experimental noise of our electrical device, it is shown that the maximum measurable value of thermal conductivity is near 23 W m−1 K−1 in vacuum and 37 W m−1 K−1 in ambient air conditions. Moreover, the lowest uncertainties are obtained for thermal conductivities below 5 W m−1 K−1 typically.

1 July 2002 in Ultramicroscopy
Verified
Journal Article
Closed access
LTL. Thiery
L. Thiery
NMN. Marini
N. Marini

14 May 2019 in Journal of Heat Transfer
Verified
Journal Article
Closed access
PDF file
TNT. P. Nguyen
T. P. Nguyen
LTL. Thiery
L. Thiery
SESébastien Euphrasie
Sébastien Euphrasie
ELEtienne Lemaire
Etienne Lemaire
SKSaleem Khan
Saleem Khan
PVP. Vairac
P. Vairac

17 August 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
SKSaleem Khan
Saleem Khan
TNTran Phong Nguyen
Tran Phong Nguyen
LTLaurent Thiery
Laurent Thiery
PVPascal Vairac
Pascal Vairac
DBDanick Briand
Danick Briand
We report on printed flexible micro-hotplates operating at high temperature at lower power consμmption than ever reported using aerosol jet printing of fine metallic conductor features. Efficient heating (i.e., 40 mW at 325 °C) was produced by reducing the effective heating area and substrates thickness. Gold (Au) nanoparticles solution was used for printing micro-hotplates of two different sizes, i.e., 500 × 500 μm2 and 300 × 300 μm2, on 50 μm- and 13 μm-thick PI substrates, respectively. Comsol simulations were used to optimize the thermal design of micro-hotplates. Their power consμmption at 325 °C was of 54 mW for the large hotplate and of 40 mW for the smaller design. These results validate the simple manufacturing of high temperature and power efficient flexible micro-hotplates for applications such as in portable gas and chemical sensors, thermal metrology, etc.

1 April 1994 in Optics Communications
Verified
Journal Article
Closed access
LTL. Thiery
L. Thiery
RPR. Porcar
R. Porcar
JPJ.P. Prenel
J.P. Prenel