Carsten Brink

Carsten Brink

Auto-generated profile, based on publicly available information

Carsten Brink

Laboratory of Radiation Physics, Odense University Hospital, Odense, Denmark

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2006 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
TKTommy Knöös
Tommy Knöös
EWElinore Wieslander
Elinore Wieslander
LCLuca Cozzi
Luca Cozzi
CBCarsten Brink
Carsten Brink
AFAntonella Fogliata
Antonella Fogliata
SLSøren Lassen
Søren Lassen
A study of the performance of five commercial radiotherapy treatment planning systems (TPSs) for common treatment sites regarding their ability to model heterogeneities and scattered photons has been performed. The comparison was based on CT information for prostate, head and neck, breast and lung cancer cases. The TPSs were installed locally at different institutions and commissioned for clinical use based on local procedures. For the evaluation, beam qualities as identical as possible were used: low energy (6 MV) and high energy (15 or 18 MV) x-rays. All relevant anatomical structures were outlined and simple treatment plans were set up. Images, structures and plans were exported, anonymized and distributed to the participating institutions using the DICOM protocol. The plans were then re-calculated locally and exported back for evaluation. The TPSs cover dose calculation techniques from correction-based equivalent path length algorithms to model-based algorithms. These were divided into two groups based on how changes in electron transport are accounted for ((a) not considered and (b) considered). Increasing the complexity from the relatively homogeneous pelvic region to the very inhomogeneous lung region resulted in less accurate dose distributions. Improvements in the calculated dose have been shown when models consider volume scatter and changes in electron transport, especially when the extension of the irradiated volume was limited and when low densities were present in or adjacent to the fields. A Monte Carlo calculated algorithm input data set and a benchmark set for a virtual linear accelerator have been produced which have facilitated the analysis and interpretation of the results. The more sophisticated models in the type b group exhibit changes in both absorbed dose and its distribution which are congruent with the simulations performed by Monte Carlo-based virtual accelerator.

8 February 2007 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
AFAntonella Fogliata
Antonella Fogliata
EVEugenio Vanetti
Eugenio Vanetti
DADirk Albers
Dirk Albers
CBCarsten Brink
Carsten Brink
ACAlessandro Clivio
Alessandro Clivio
LCLuca Cozzi
Luca Cozzi
A comparative study was performed to reveal differences and relative figures of merit of seven different calculation algorithms for photon beams when applied to inhomogeneous media. The following algorithms were investigated: Varian Eclipse: the anisotropic analytical algorithm, and the pencil beam with modified Batho correction; Nucletron Helax-TMS: the collapsed cone and the pencil beam with equivalent path length correction; CMS XiO: the multigrid superposition and the fast Fourier transform convolution; Philips Pinnacle: the collapsed cone. Monte Carlo simulations (MC) performed with the EGSnrc codes BEAMnrc and DOSxyznrc from NRCC in Ottawa were used as a benchmark. The study was carried out in simple geometrical water phantoms (rho = 1.00 g cm(-3)) with inserts of different densities simulating light lung tissue (rho = 0.035 g cm(-3)), normal lung (rho = 0.20 g cm(-3)) and cortical bone tissue (rho = 1.80 g cm(-3)). Experiments were performed for low- and high-energy photon beams (6 and 15 MV) and for square (13 x 13 cm2) and elongated rectangular (2.8 x 13 cm2) fields. Analysis was carried out on the basis of depth dose curves and transverse profiles at several depths. Assuming the MC data as reference, gamma index analysis was carried out distinguishing between regions inside the non-water inserts or inside the uniform water. For this study, a distance to agreement was set to 3 mm while the dose difference varied from 2% to 10%. In general all algorithms based on pencil-beam convolutions showed a systematic deficiency in managing the presence of heterogeneous media. In contrast, complicated patterns were observed for the advanced algorithms with significant discrepancies observed between algorithms in the lighter materials (rho = 0.035 g cm(-3)), enhanced for the most energetic beam. For denser, and more clinical, densities a better agreement among the sophisticated algorithms with respect to MC was observed.

31 July 2019 in Acta Oncologica
Verified
Journal Article
Closed access
SAS. Aarup-Kristensen
S. Aarup-Kristensen
CHChristian Rønn Hansen
Christian Rønn Hansen
LFL. Forner
L. Forner
CBC. Brink
C. Brink
JEJ. G. Eriksen
J. G. Eriksen
JJJ. Johansen
J. Johansen
Background: The project aimed at determining the incidence of mandibular osteoradionecrosis (ORN) after radiotherapy, possible risk factors, and mandibular dose-volume effects in a large cohort of head and neck cancer patients (HNC). Methods: The cohort consisted of 1224 HNC patients treated with 66–68 Gy in 2007–2015 predominantly with IMRT. ORN cases were defined from clinical observations at follow-up and through hospital code diagnostics after oral-maxillofacial surgery and cross-checked with the national Danish Head and Neck Cancer database. In a nested case–control study, patients with ORN cases were matched with two controls (1:2) and pre-RT dental procedures including surgery to the mandible were documented. Multivariable Cox regression analysis was applied using demographic and treatment variables including dental procedures, smoking and tumor characteristics, and combined with dosimetric data. Mean mandibular dose (Dmean) was pre-selected for the multivariable model. Results: ORN was recorded in 56 cases (4.6%) with a median time to event of 10.9 months (range 1.8–89.7) after RT, 90% occurred within 37.4 months. Median follow-up time was 22 months (0.3–95). Average Dmean was significantly higher in the ORN event cohort and significant dose-volume differences were observed for population mean DVH doses between 30 Gy and 60 Gy. In univariable analysis, smoking (HR = 1.69; CI 1.14–2.5), pre-RT surgery/tooth extraction (HR = 2.76; 1.48–5.14), and several dosimetric parameters including Dmean (HR = 1.05, 1.02–1.08) were all significantly associated with ORN. Dmean and surgery/tooth extraction remained significant predictors of ORN in multivariable analysis, HR = 1.04 (CI 1.01–1.07) and HR = 2.09 (CI 1.1–3.98), respectively, while smoking only retained its significance in an interaction analysis with pre-RT dental procedures. Conclusion: The onset of ORN of the mandible was early (median 10.8 months) and the incidence low (4.6%) after IMRT in HNC cancer patients. Surgery to the mandible and pre-RT tooth extraction, tobacco smoking, and treatment dose were associated with the development of ORN.

1 June 2017 in Radiotherapy and Oncology
Verified
Journal Article
Open access
JTJanita E. van Timmeren
Janita E. van Timmeren
RLRalph T.H. Leijenaar
Ralph T.H. Leijenaar
WEWouter van Elmpt
Wouter van Elmpt
BRBart Reymen
Bart Reymen
COCary Oberije
Cary Oberije
PLPhilippe Lambin
Philippe Lambin
In this study we investigated the interchangeability of planning CT and cone-beam CT (CBCT) extracted radiomic features. Furthermore, a previously described CT based prognostic radiomic signature for non-small cell lung cancer (NSCLC) patients using CBCT based features was validated. One training dataset of 132 and two validation datasets of 62 and 94stage I-IV NSCLC patients were included. Interchangeability was assessed by performing a linear regression on CT and CBCT extracted features. A two-step correction was applied prior to model validation of a previously published radiomic signature. Results 13.3% (149 out of 1119) of the radiomic features, including all features of the previously published radiomic signature, showed an R2 above 0.85 between intermodal imaging techniques. For the radiomic signature, Kaplan-Meier curves were significantly different between groups with high and low prognostic value for both modalities. Harrell's concordance index was 0.69 for CT and 0.66 for CBCT models for dataset 1. Conclusions The results show that a subset of radiomic features extracted from CT and CBCT images are interchangeable using simple linear regression. Moreover, a previously developed radiomics signature has prognostic value for overall survival in three CBCT cohorts, showing the potential of CBCT radiomics to be used as prognostic imaging biomarker.

1 May 2010 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
ABAnders Bertelsen
Anders Bertelsen
CHChristian Rønn Hansen
Christian Rønn Hansen
JJJørgen Johansen
Jørgen Johansen
CBCarsten Brink
Carsten Brink

8 January 2016 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
IHIrene Hazell
Irene Hazell
KBKarl Bzdusek
Karl Bzdusek
PKPrashant Kumar
Prashant Kumar
CHChristian Rønn Hansen
Christian Rønn Hansen
ABAnders Bertelsen
Anders Bertelsen
CBCarsten Brink
Carsten Brink
Treatment planning is time‐consuming and the outcome depends on the person performing the optimization. A system that automates treatment planning could potentially reduce the manual time required for optimization and could also provide a method to reduce the variation between persons performing radiation dose planning (dosimetrist) and potentially improve the overall plan quality. This study evaluates the performance of the Auto‐Planning module that has recently become clinically available in the Pinnacle3 radiation therapy treatment planning system. Twenty‐six clinically delivered head and neck treatment plans were reoptimized with the Auto‐Planning module. Comparison of the two types of treatment plans were performed using DVH metrics and a blinded clinical evaluation by two senior radiation oncologists using a scale from one to six. Both evaluations investigated dose coverage of target and dose to healthy tissues. Auto‐Planning was able to produce clinically acceptable treatment plans in all 26 cases. Target coverages in the two types of plans were similar, but automatically generated plans had less irradiation of healthy tissue. In 94% of the evaluations, the autoplans scored at least as high as the previously delivered clinical plans. For all patients, the Auto‐Planning tool produced clinically acceptable head and neck treatment plans without any manual intervention, except for the initial target and OAR delineations. The main benefit of the method is the likely improvement in the overall treatment quality since consistent, high‐quality plans are generated which even can be further optimized, if necessary. This makes it possible for the dosimetrist to focus more time on difficult dose planning goals and to spend less time on the more tedious parts of the planning process.PACS number: 87.55.de