Thomas Hüfken

Thomas Hüfken

Auto-generated profile, based on publicly available information

Thomas Hüfken

Department of Internal Medicine II, University Hospital of Ulm, Ulm, Germany

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2022 in Zeitschrift für Medizinische Physik
Verified
Journal Article
Open access
THThomas Hüfken
Thomas Hüfken
JAJannik M. Arbogast
Jannik M. Arbogast
ABAnna-Katinka Bracher
Anna-Katinka Bracher
Meinrad BeerMeinrad Beer
Meinrad Beer
HNHenning Neubauer
Henning Neubauer
VRVolker Rasche
Volker Rasche
To develop a model-based reconstruction technique for diffusion quantification based on accelerated two-dimensional echo planar data, obtained with multiple b-weightings. In combination with a dedicated undersampling pattern, acceleration factors above three were proven feasible in a clinical setting. The proposed model-based method minimizes a cost function considering the l2-norm of the difference between the Fourier transformation of a synthetic diffusion-model-generated k-space and the measured k-space data. Further regularization is performed by introduction of a total variation (TV) constraint to the cost function. Acceleration is achieved by a non-random undersampling pattern using acceleration factors that correspond to the total number of b-values. A rectangular region of variable size, centered in k-space, remains fully sampled for correction of phase variations, introduced by the different diffusion-encoding strengths. Qualitative analysis of the resulting images (S0 and ADC) demonstrates the potential of the suggested undersampling pattern in combination with a model-based iterative reconstruction. An edge analysis highlights the preservation of high-frequency information for all investigated undersampling factors. In comparison to a conventional SENSE-accelerated reconstruction, the quantitative analysis of the ADC maps revealed a significantly (P<0.05) superior performance of the suggested technique, enabling acceleration factors of R=3.65 without compromising diffusion data fidelity. The presented work shows the potential of model-based ADC quantification, which, in combination with a suited undersampling pattern for multiple b-values, enables more than three-fold acceleration using two-dimensional EPI without sacrificing ADC fidelity.

9 December 2024 in IEEE Sensors Journal
Verified
Journal Article
Open access
FBFabian Bschorr
Fabian Bschorr
THThomas Hüfken
Thomas Hüfken
TLTobias Lobmeyer
Tobias Lobmeyer
FDFrederik Dreyer
Frederik Dreyer
JZJianyu Zhao
Jianyu Zhao
VRVolker Rasche
Volker Rasche
The aim of this study was to evaluate the feasibility of an NMR-on-a-chip sensor as local field probe for contactless monitoring of respiratory and cardiac motion-induced field changes and to investigate their applicability for motion synchronization in MRI. Cardiac and respiratory motion-induced field changes were recorded at 7 positions around the torso of 6 volunteers. The data were analysed regarding cardiac and respiratory components and the most promising location for assessment of respiratory motion identified. Further, the sensor-derived signal was correlated with the vendor-provided respiratory belt. The cranial parasternal positions were identified as excellent candidates for mapping cardiac motion, whereas the anterior locations at height of the diaphragm appear most promising for mapping of the respiration. Realtime analysis of the recorded signals was successfully applied for respiratory synchronization of the MR system and showed very good correlation with the respiratory belt with less fluctuation and shorter transient phase during breath-holding. NMR-on-a-chip sensors are sensitive enough for monitoring physiological motion and can be applied for respiratory motion synchronization. Depending on the positioning of the sensor, cardiac as well as respiratory induced field changes can be contactless mapped and used for synchronization of the MRI.

9 June 2022 in Frontiers in Physics
Verified
Journal Article
Open access
TSTobias Speidel
Tobias Speidel
PMPatrick Metze
Patrick Metze
KSKilian Stumpf
Kilian Stumpf
THThomas Hüfken
Thomas Hüfken
VRVolker Rasche
Volker Rasche
This manuscript describes a method of three-dimensional k-space sampling that is based on a generalised form of the previously introduced “Seiffert Spirals,” which exploits the equality between undersampling and the reconstruction of a field of view which is larger than what is represented by the primary sampling density, leading to an imaging approach that does not require any prior commitment to an imaging field of view. The concept of reconstructing arbitrary FOVs based on a low-coherently sampled k-space is demonstrated analytically by simulations of the corresponding point spread functions and by an analysis of the noise power spectrum of undersampled datasets. In-vivo images highlight the feasibility of the presented approach by reconstructing white noise governed images from an undersampled datasets with a smaller encoded FOV. Beneficial properties are especially given by an artefact behaviour, which is widely comparable to the introduction of white noise in the image domain. Furthermore, these aliasing properties provide a promising precondition for the combination with non-linear reconstruction techniques such as Compressed Sensing. All presented results show dominant low-coherent aliasing properties, leading to a noise-like aliasing behaviour, which enables parameterization of the imaging sequence according to a given resolution and scan-time, without the need for FOV considerations.