17 May 2022 in IEEE Transactions on Industrial Electronics
The medium-frequency (MF) transformer in a phase-shift modulated dc solid state transformer (SST) is prone to partial discharge (PD) that impacts the system reliability and lifetime. Tightly packed MF transformer windings carrying pulsewidth modulation (PWM) voltages create favorable conditions for PD inception due to proximity between adjacent winding conductors and electric field enhancement because of spiral geometry. A peak potential condition is created between the adjacent posterior conductors of the primary and secondary windings as a result of phase-shifted modulation. This along with fast alternating electric fields incepts PD at lower than expected operating voltages. Early inception of PD leads to premature transformer failure leading to unanticipated dc SST down-time. The effects of PWM voltages containing high dv/dt switching transients on PD and lifetime characteristics of MF transformer in a dc SST are not yet understood, which is investigated in this article. A nonintrusive PD detection strategy for MF PWM ac voltage is presented using high-speed optical sensors. PD characterization is performed on Kapton polyimide insulated copper foil windings for a foil-type MF transformer. Winding samples are stress tested with steady state PWM voltages up to 2 kV and frequencies up to 50 kHz with high dv/dt up to 60 V/ns generated by a half-bridge inverter using 3.3 kV SiC devices while maintaining the transformer's geometric profile. Accelerated dielectric lifetime characterization is also performed and novel lifetime prediction models are derived based on the acquired results containing both frequency and dv/dt dependent variables.
10 November 2017 in IEEE Transactions on Power Electronics
This paper proposes an adaptive Look-up-table (LUT)-based variable on-time (VOT) control for CRM boost PFC converters, which combines advantages of conventional LUT method and real-time calculation method. By the numerical fitting method, the functional form of on-time is derived, which is related to both the input voltage and load. The mapping relationships of VOT tables under different load and input voltage are investigated. Based on the mapping relationships, only one VOT table is required to be preloaded. The adaptability of proposed control is conveniently realized within the universal AC input and entire load range with inherent voltage control loop and a simple linear calculation. Thus, with the proposed control, the required memory space for VOT table is effectively reduced and the computation time is significantly shortened, which leads to a reduction of system cost. Moreover, compared with the constant on-time (COT) control and other VOT control methods, the proposed control can further suppress the input current distortion. An 160-W universal AC input prototype was built to verify the effectiveness and the advantage. With the proposed control, the input current THD is only 0.97% at 110Vac input under full load and is limited within 2.9% at 220Vac input under full load.
20 April 2018 in IEEE Transactions on Power Electronics
This paper proposes an improved zero current detection (ZCD) for critical conduction mode (CRM) control, which can compensate the input current distortion caused by the signal propagation delay and the existence of the negative resonance current. A unified variable on-time (VOT) calculation method is also proposed to unify the formulas under the zero-voltage-switching (ZVS) condition and the valley-switching (VS) condition. Since these two methods are dependent on the boost inductance and device junction capacitance, which may be different from the nominal values, effort is needed to compensate the deviation on these two parameters. In this paper, an online monitoring method is proposed to compensate the numerical deviation. The proposed method only needs to sense the input voltage, output voltage and the reverse flow time of the inductor current, leading to a high power quality in the entire input and load conditions. The experimental results of the proposed methods are demonstrated on a 200W GaN-based CRM boost PFC prototype. With the proposed methods, the input current THD is only 0.78% at 110Vac input with full load and 2.1% at 220Vac input with full load.
9 March 2022 in IEEE Transactions on Power Electronics
The conventional isolated gate driver (GD) solution for the medium-voltage (MV) SiC mosfet separates the signal and power transmissions and requires a bulky GD power supply (GDPS). This article presents a signal-power integrated GD for MV SiC mosfet s with a compact footprint. The proposed GD transmits both the pulsewidth modulation (PWM) signal and GD power by 20-MHz modulated class-E resonant flyback converters, where the transmitted GD power can maintain constant within the full PWM duty-cycle range (i.e., 0%–100%). In addition, the PWM signal transmission of the proposed GD achieves a low total propagation delay time < 75 ns by utilizing the fast transient of 20-MHz RFCs and the edge-based envelope detector. A printed-circuit-board-based coreless transformer is integrated into the proposed GD to achieve an insulation voltage higher than 10 kV RMS and a low coupling capacitance of 5.85 pF. The common-mode transient immunity of proposed GD is higher than 100 V/ns, which is beneficial to drive MV SiC mosfet s with high dv/dt . The proposed GD does not require additional GDPSs nor fiber-optics, which achieves a smaller size compared to conventional isolated GDs and is promising to be integrated into SiC mosfet module packages. Experimental results on 3.3 kV and 10 kV SiC mosfet s are provided to validate the effectiveness of the proposed GD.
4 July 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
In order to suppress the input current distortion of critical conduction mode (CRM) boost power factor correction (PFC) converters, variable on-time (VOT) control has been adopted in many analog commercial integrated chips (ICs). However, the quantitative VOT expression applicable to analog control has not been studied until now. According to the fitting functional form of VOT, this paper proposes a uniform and simple VOT expression, which can be directly implemented by analog circuits and provide accurate VOT just as digital control. Only an inverse signal of the rectified input voltage is additionally introduced to achieve accurate VOT, and the inherent voltage feedback loop of PFC is utilized to eliminate the effect of the input RMS voltage and output power. With the proposed quantitative design consideration, the optimum input current total harmonics distortion (THD) is naturally obtained without trial-and-error design. The experimental results of a 160-W prototype are built to verify the effectiveness and advantages of the proposed VOT control.
1 June 2023 in IEEE Transactions on Power Electronics
This letter presents a novel short-circuit protection (SCP) for medium-voltage (MV) SiC mosfet s, that utilizes the turn- on dv/dt of SiC mosfet within a predetermined interval to monitor SC faults. Unlike conventional methods that detect the fault current/voltage magnitude, proposed turn- on dv/dt detection and protection timing sequence enable a very fast fault response time as well as enhance the noise immunity to fast switching of MV SiC mosfet s. Furthermore, the proposed dv/dt sensing based SCP can be integrated with DESAT circuit to provide over-current protection under the fault-under-load condition. The proposed integrated implementation can respond to SC faults without the blanking-time limitation and eliminates the need for the extra high-voltage sensing capacitor to lower cost. Experimental results on 3.3-kV SiC mosfet s are provided to validate the effectiveness of proposed SCP method.