Feifan Chen

Feifan Chen

Auto-generated profile, based on publicly available information

Feifan Chen

School of Electrical Engineering and Computer Science, KTH Royal Institute of Technology, Stockholm, Sweden

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
GWGaolin Wang
Gaolin Wang
FCFeifan Chen
Feifan Chen
NZNannan Zhao
Nannan Zhao
YBYin Bai
Yin Bai
BLBinxing Li
Binxing Li
DXDianguo Xu
Dianguo Xu
Because of the time-sharing sampling logic, the three-phase currents reconstructed by single DC-link shunt present significant errors in the permanent magnet synchronous motor (PMSM) drives. A traceback-prediction current correction method for sampled currents is proposed in this paper to eliminate the reconstruction errors. According to the analysis of time-sharing sampling errors, the concept of equivalent current change rate during one PWM period is introduced, and the phase current characteristic model based on state observer is established. Both the equivalent and instantaneous current change rates can be obtained by the observer-based calculation method. In order to improve the current reconstruction precision, the ultimate values of three-phase currents can be predicted by adopting the proposed traceback-prediction current correction method, which does not require major computation and is easy to implement with no restrictions on the PWM strategy. The effectiveness of the proposed method is verified by experimental results

19 October 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FCFeifan Chen
Feifan Chen
LZLiang Zhao
Liang Zhao
LHLennart Harnefors
Lennart Harnefors
XWXiongfei Wang
Xiongfei Wang
JKJarno Kukkola
Jarno Kukkola
MRMikko Routimo
Mikko Routimo
The phase-locked loop (PLL) is a commonly used synchronization control method for grid-tied inverters. The PLL-synchronized inverters tend to have poor stability robustness with weak grid interconnections, especially when the PLL is designed with a high control bandwidth. To tackle this challenge, this article proposes an enhanced q -axis voltage-integral damping control, which not only stabilizes PLL-synchronized inverters in weak grids but also lifts the restriction on PLL bandwidth. This superior feature enables inverters to operate stably in ultraweak grids and with a superior transient response. The experimental tests confirm the performance of the method with 400-Hz PLL bandwidth under a short-circuit ratio of 1.28 of the grids.

15 July 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FCFeifan Chen
Feifan Chen
XWXiongfei Wang
Xiongfei Wang
LHLennart Harnefors
Lennart Harnefors
SKSei Zhen Khong
Sei Zhen Khong
DWDan Wang
Dan Wang
KJKarl Henrik Johansson
Karl Henrik Johansson
The main purpose of this article is to elaborate on the limitations of using frequency-domain passivity theories in analyzing grid-inverter interactions within the low-frequency range. It primarily covers three levels of limitations: 1) the limitations and selection criteria of two kinds of passivity index, 2) potential conflicts between different passivity index tuning methods, and 3) the relationship between the frequency range of negative passivity index and system stability robustness. The findings suggest that caution should be exercised when applying passivity theory, particularly in the low-frequency range.

20 December 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
LZLianghong Zhu
Lianghong Zhu
FCFeifan Chen
Feifan Chen
BLBinxing Li
Binxing Li
Chengrui LiChengrui Li
Chengrui Li
GWGaolin Wang
Gaolin Wang
DXDianguo Xu
Dianguo Xu
The extensive application of vector phase shift modulation method in permanent magnet synchronous motor drive systems with single dc-link current sensor results in obvious current ripple in the low-speed region. The patterns of these ripples vary greatly in different sectors, leading to nonnegligible phase current reconstruction errors. In this article, an estimation of the local average current change rate (ELAC 2 R) based reconstruction error suppression method within the switching cycle is proposed to resolve this problem. By comparing the actual and the ideal sampling points, the increase of current ripple and the reconstruction error caused by the combination of the vector phase shift and the single current sensor sampling in the low-speed region are modelled and analyzed. Then according to equivalent modelling of the current ripple between the ideal and the actual sampling points, the more accurate phase current information can be quickly obtained based on the sampling value. The compensation process is significantly simplified and the computation burden of the processor is reduced. Experimental results show that the performance of current reconstruction can be improved effectively with less harmonic content with the proposed method.

30 October 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FCFeifan Chen
Feifan Chen
SKSei Zhen Khong
Sei Zhen Khong
LHLennart Harnefors
Lennart Harnefors
XWXiongfei Wang
Xiongfei Wang
DWDan Wang
Dan Wang
KJKarl Henrik Johansson
Karl Henrik Johansson
In grid-connected inverter systems, frequency-domain passivity theory is increasingly employed to analyze grid–inverter interactions and guide inverter control designs. However, due to difficulties in meeting sufficient passivity-based stability conditions at low frequencies, passivity theory often falls short of achieving stable system specifications. This article introduces an extended frequency-domain passivity theory. By incorporating a weighting matrix, an extended stability condition is derived. Compared to conventional passivity-based stability conditions, the proposed theory significantly reduces conservativeness and is more suited for analyzing grid–inverter interactions and guiding inverter control design. Theoretical analyses, numerical examples, and experimental results are provided to validate the effectiveness of the proposed methods.

4 September 2025 in IEEE Transactions on Smart Grid
Verified
Journal Article
Open access
FCFeifan Chen
Feifan Chen
XWXiongfei Wang
Xiongfei Wang
LHLennart Harnefors
Lennart Harnefors
SKSei Zhen Khong
Sei Zhen Khong
JKJarno Kukkola
Jarno Kukkola
KJKarl Henrik Johansson
Karl Henrik Johansson
This article addresses small-signal stability issues for multi-parallel grid-forming converter systems based on a newly developed extended passivity theory. The proposed methods provide streamlined, decentralized stability conditions that cover the full frequency range with reduced conservativeness, serving as theoretical tools and practical guidelines for assessment, cause localization, and mitigation of small-signal instability risks in such systems. Numerical examples and experimental results are provided to verify the effectiveness of the proposed methods.