Liang Zhao

Liang Zhao

Auto-generated profile, based on publicly available information

Liang Zhao

KTH Royal Institute of Technology

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
LZLiang Zhao
Liang Zhao
ZJZheming Jin
Zheming Jin
XWXiongfei Wang
Xiongfei Wang
The dc-link voltage dynamics can be directly used to synchronize grid-forming (GFM) converters with ac grids. However, such control scheme is prone to unstable low-frequency oscillations (LFO), owing to the constant-power dynamics at the dc link. This article analyzes first the small-signal stability of dc-link voltage-synchronized GFM converters, and proposes a control method for enhancing the system stability under different operating scenarios. In the approach, a q -axis voltage-feedforward control is introduced in parallel with the dc-link voltage control for the grid-synchronization purpose. The LFO problem with the conventional dc-link voltage-synchronization control is mitigated. Compared to conventional cascaded/paralleled dc-link voltage- and active power-based synchronization, the method mitigates the synchronous oscillation problem. Experimental tests are performed for the GFM converter operating in both rectifier and inverter modes and with different grid strengths. The results corroborate theoretical analyses and validate the effectiveness of the approach.

8 January 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HWHeng Wu
Heng Wu
XWXiongfei Wang
Xiongfei Wang
LZLiang Zhao
Liang Zhao
There is an increasing demand on the grid-forming (GFM) capability of grid-connected voltage-source converters under large grid disturbances, even when the current-limiting control (CLC) is triggered. This letter demonstrates that the GFM capability can be maximized by matching the angle of virtual impedance emulated by the CLC and that of the passive impedance composed by filter impedance and grid impedance. This finding offers insight for optimizing the CLC with the enhanced GFM capability. The experimental results are given to verify the theoretical findings.

31 March 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
LZLiang Zhao
Liang Zhao
ZJZheming Jin
Zheming Jin
XWXiongfei Wang
Xiongfei Wang
For grid-connected voltage-source converters (VSCs), the dc-link voltage control can be merged with the power-based-synchronization control, leading to the dc-link voltage-synchronization control. This article analyzes the low-frequency oscillations of dc-link voltage-synchronized VSCs, which is due to the impact of constant-power load/source (CPL/CPS) in the dc link. An active damping method, based on the active power–frequency feedforward (PFF) control with a notch filter, is proposed to dampen the oscillations. It is revealed that the PFF control loop exploits the phase angle dynamic to resist the frequency deviation, which can be essentially treated as an active damper against the dynamics of dc-link CPL/CPS. Furthermore, a loop-gain shaping method is developed for designing the notch filter, which dampens the synchronous oscillations that is inherent with active power dynamics. Experimental tests are performed under different grid frequencies and strengths, considering both the rectifier and inverter operation modes. The results validate the theoretical analysis and the effectiveness of the control approach.

13 May 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YLYufei Li
Yufei Li
YLYicheng Liao
Yicheng Liao
LZLiang Zhao
Liang Zhao
MCMinjie Chen
Minjie Chen
XWXiongfei Wang
Xiongfei Wang
H. Vincent PoorH. Vincent Poor
H. Vincent Poor
It is envisioned that the future electric grid will be underpinned by a vast number of smart inverters linking renewables at the grid edge. These inverters' dynamics are typically characterized as impedances, which are crucial for ensuring grid stability and resiliency. However, the physical implementation of these inverters may vary widely and may be kept confidential. Existing analytical impedance models require a complete and precise understanding of system parameters. They can hardly capture the complete electrical behavior when the inverters are performing complex functions. Online impedance measurements for many inverters across multiple operating points are impractical. To address these issues, we present the I nvNet , a machine learning framework capable of characterizing inverter impedance patterns across a wide operation range, even with limited impedance data. Leveraging transfer learning, the I nvNet can extrapolate from physics-based models to real-world ones and from one inverter to another with the same control framework but different control parameters with very limited data. This framework demonstrates machine learning as a powerful tool for modeling and analyzing black-box characteristics of grid-tied inverter systems that cannot be accurately described by traditional analytical methods, such as inverters under model predictive control. Comprehensive evaluations were conducted to verify the effectiveness of the I nvNet . All data and models have been open-sourced

22 June 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
LZLiang Zhao
Liang Zhao
XWXiongfei Wang
Xiongfei Wang
ZJZheming Jin
Zheming Jin
This article presents ac- and dc-side impedance-based dynamic analyses for voltage-source converters (VSCs) using dc-link voltage-synchronization control. Stability impacts of different types of dc-ink loads and sources are examined. It is found that the constant power load exhibits higher instability risk than the constant-current and constant-resistance loads at the dc link of VSC. Further, it is shown that in the rectifier mode, all the dc-link loads lead to negative resistance at the d - d channel of ac impedance matrix in the low-frequency range, whereas in the inverter mode, the dc-link constant-current and constant-power sources cause a negative resistance at the q - q channel of ac impedance matrix. These negative resistances may lead to oscillations when interacting with grid impedance. To mitigate instability risks, the active power-frequency feedforward control and the q -axis voltage-frequency feedforward control are used, respectively, in parallel with the dc-link voltage control of VSC. Experimentally measured impedance profiles and dynamics testing results corroborate the theoretical findings and the effectiveness of the control methods.

19 October 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FCFeifan Chen
Feifan Chen
LZLiang Zhao
Liang Zhao
LHLennart Harnefors
Lennart Harnefors
XWXiongfei Wang
Xiongfei Wang
JKJarno Kukkola
Jarno Kukkola
MRMikko Routimo
Mikko Routimo
The phase-locked loop (PLL) is a commonly used synchronization control method for grid-tied inverters. The PLL-synchronized inverters tend to have poor stability robustness with weak grid interconnections, especially when the PLL is designed with a high control bandwidth. To tackle this challenge, this article proposes an enhanced q -axis voltage-integral damping control, which not only stabilizes PLL-synchronized inverters in weak grids but also lifts the restriction on PLL bandwidth. This superior feature enables inverters to operate stably in ultraweak grids and with a superior transient response. The experimental tests confirm the performance of the method with 400-Hz PLL bandwidth under a short-circuit ratio of 1.28 of the grids.