11 July 2018 in IEEE Sensors Journal
This paper presents a flexible ultraviolet (UV) photodetector (PD) system based on zinc oxide (ZnO) nanowires (NWs) for wearable UV dosimetry. High-crystal quality ZnO NWs have been synthesized by chemical vapour transport technique on c-plane sapphire substrates, and thereafter, transferred and aligned at pre-defined locations on a flexible substrate using dielectrophoresis (DEP). The accurate control over DEP parameters permitted the fabrication of large-area (wafer scale) arrays of ZnO NWs-based UV PDs. Resulting PDs showed photocurrent-to-dark current ratios above 10 3 %, fast response times (<;1 s), high sensitivity to different UV light intensities, and good stability under several UV/dark irradiation cycles. In addition, above PDs presented a robust response under extreme bending conditions, which is critical for their application in high-performance wearable UV dosimeters.
23 February 2017 in IEEE Transactions on Electron Devices
The field of flexible electronics is rapidly evolving. The ultrathin chips are being used to address the high-performance requirements of many applications. However, simulation and prediction of changes in response of device/circuit due to bending induced stress remains a challenge as of lack of suitable compact models. This makes circuit designing for bendable electronics a difficult task. This paper presents advances in this direction, through compressive and tensile stress studies on transistors and simple circuits such as inverters with different channel lengths and orientations of transistors on ultrathin chips. Different designs of devices and circuits in a standard CMOS 0.18-μm technology were fabricated in two separated chips. The two fabricated chips were thinned down to 20 μm using standard dicing-before-grinding technique steps followed by post-CMOS processing to obtain sufficient bendability (20-mm bending radius, or 0.05% nominal strain). Electrical characterization was performed by packaging the thinned chip on a flexible substrate. Experimental results show change of carrier mobilities in respective transistors, and switching threshold voltage of the inverters during different bending conditions (maximum percentage change of 2% for compressive and 4% for tensile stress). To simulate these changes, a compact model, which is a combination of mathematical equations and extracted parameters from BSIM4, has been developed in Verilog-A and compiled into Cadence Virtuoso environment. The proposed model predicts the mobility variations and threshold voltage in compressive and tensile bending stress conditions and orientations, and shows an agreement with the experimental measurements (1% for compressive and 0.6% for tensile stress mismatch).
15 July 2019 in IEEE Sensors Journal
This work presents a Chitosan - Graphene Oxide (CS-GO) based array of ultra-thin biosensors with gold (Au) based microgap (60μm) electrode. The cross-linked GO is shown to improve the stability of chitosan substrate in aqueous medium and compatibility with microfabrication steps. The sensor patch has been evaluated for label free monitoring by immobilizing the CS-GO surface with human dermal fibroblast (HDF) cells. The cyclic voltammetry (CV) of HDF cell immobilized CS-GO surface show quasi-reversible nature with characteristic cathodic peak at 300mV and anodic peak at +300mV. Both peaks are stable and repeatable up to 50-scan cycle without any potential shift. The device shows steady state peak enhancement (1.923-11.195nA) during the DHF cell growth period (0-96h). The redox peak enhancement correlates with the cell proliferation rates over time, indicating that it could be employed for investigation of cyto-physiological state against any endo and exogenous stimulation. In addition, the developed sensor-patch was used to detect a wide range of glucose from 1μM to 20mM in vitro with a sensitivity of 0.17μA/mM. Considering these, the presented sensor-patch has a great potential for the detection of glucose level, cell-health proliferation rate at the wound site and diabetic wound monitoring applications.
28 May 2018 in IEEE Sensors Journal
This paper presents printed thick film Ag| AgCl| KCl reference electrodes (RE) for electrochemical sensors. The screen-printed REs with 10μ m thick glass-KCl salt matrix layer exhibit a stable potential of 5 mV. Cyclic voltammetric analysis shows that the anodic and cathodic peak current of the RE increases with the scan rate in the range of 25-150 mVs-1. The analytical performance of the REs shows a stable open circuit potential for the NaCl concentrations in the range of 30-100 mM. Testing the presented REs for electrochemical pH sensor application (with RuO2 based sensitive electrode) the sensitivity of 55 mV/pH was noted in the pH range of 4.5 to 9. Evaluating the effect of temperature on the performance of REs, a potential variation of -3.8 mV/°C was observed. Finally, a LabVIEW interface was developed to store, analyze, and calculate the sensitivity of the sensor under different temperature conditions. The LabVIEW interface can also be used to calculate the pH-value/temperature of unknown solutions under known temperature/pH conditions.
16 November 2016 in IEEE Transactions on Circuits and Systems I: Regular Papers
Flexible electronics is rapidly evolving towards devices and circuits to enable numerous new applications. The high-performance, in terms of response speed, uniformity and reliability, remains a sticking point. The potential solutions for high-performance related challenges bring us back to the time-tested silicon based electronics. However, the changes in the response of silicon based devices due to bending related stresses is a concern, especially because there are no suitable models to predict this behavior. This also makes the circuit design a difficult task. This paper reports advances in this direction, through our research on bendable piezoelectric oxide semiconductor field effect transistor (POSFET) based touch sensors. The analytical model of POSFET, complimented with Verilog- A model, is presented to describe the device behavior under normal force in planar and stressed conditions. Further, dynamic readout circuit compensation of POSFET devices have been analyzed and compared with similar arrangement to reduce the piezoresistive effect under tensile and compressive stresses. This approach introduces a first step towards the systematic modeling of stress induced changes in device response. This systematic study will help realize high-performance bendable microsystems with integrated sensors and readout circuitry on ultra-thin chips (UTCs) needed in various applications, in particular, the electronic skin (e-skin).
14 April 2020 in IEEE Transactions on Electron Devices
This article presents a detailed investigation of the impact of mechanical strain on transition metal dichalcogenide (TMD) material-based tunneling field-effect transistor (TFET). First, the impact of mechanical strain on material parameters of MoSe₂ is calculated using the first principle of density functional theory (DFT) under meta-generalized gradient approximation (MGGA). The device performance of the TMD TFET has been studied by solving the self-consistent 3-D Poisson and Schrodinger equations in nonequilibrium Green's function (NEGF) framework. The results demonstrate that both Ion and Ioff increase with uniaxial tensile strain, however the change in Ion/Ioff ratio remains small. This strain-dependent performance change in TMD TFET has been utilized to design an ultrasensitive strain sensor. The device shows a sensitivity (ΔIDS/IDS) of 3.61 for a strain of 2%. Due to the high sensitivity to the strain, these results show the potential of using MoSe₂ TFET as a flexible strain sensor. Furthermore, the strained TFET is analyzed for backend circuit performance. It is observed that the speed and energy efficiency of ten-stage inverter chain based on controlled strain improve substantially in comparison to unstrained TFETs.