7 February 2022 in IEEE Sensors Journal
Through this paper, a sensor based on localized surface plasmon resonance (LSPR) with simultaneous use of gold and aluminium doped zinc oxide (AZO) as plasmonic materials has been proffered. Incorporating these two different plasmonic materials has brought out a unique dispersion relation where double resonance peaks have been detected. After optimizing structural parameters, the simulated results have distinguished that this sensor exhibits maximum amplitude sensitivity of 8485.2 RIU-1 along with maximum wavelength sensitivity of 46300 nm/RIU in the direction of y-polarization whenever AZO is used as the middle plasmonic material. Furthermore, the sensor obtains a maximum amplitude resolution of 1.18×10-6 RIU and a maximum wavelength resolution of 2.16×10-6 RIU. A higher figure of merit of 2923.2 can also be obtained, indicating higher detection accuracy through this sensor and maximum linearity of R2 = 0.99312. Moreover, the proffered sensor has shown its ability to detect unspecified analytes with a refracting index in the maximum wide range of 1.27 to 1.45. Apart from these sensing parameters obtained from analyzing the double peaks separately, a new sensing parameter called double peak shift sensitivity has been introduced in this study. This sensor displays a maximum double peak sensitivity of 4400 nm/RIU for x-polarization mode and 16500 nm/RIU for y-polarization mode considering the double peaks together for two adjacent RIs. Due to these diverse features, the proposed design can open the doors to notable developments in a wide range of analytes and biological organic chemicals detection with ultra-high accuracy and broadband applications.
10 January 2025 in Journal of Optics
A highly sensitive polished photonic crystal fiber (PCF) sensor with an external sensing method has been proposed, which utilizes the surface plasmon resonance (SPR) optical sensing technique. The aim of this study is to develop a sensor which can be utilized to detect a vast range of analyte samples, ranging from low refractive index (RI) chemicals to high RI biomedical applications, while also considering the cost and ease of fabrication. The two polished sides are coated with a plasmonic material called aluminum-doped zinc oxide (AZO) that enhances the coupling strength and enables the SPR technology. The finite element method is employed to analyze the PCF numerically, which confirms a RI spanning from 1.18 to 1.45 for analyte detection, the highest detection extent found for AZO. After analysis, the maximum value of amplitude sensitivity was found to be 6312.34 , and the highest wavelength sensitivity of 20 500 nm RIU−1 was attained. Moreover, the PCF provides a maximum amplitude resolution of 1.58 × 10−6 RIU and wavelength resolution of 4.88 × 10−6 RIU. The confinement loss was also fairly low, perfect for longer sensor lengths. The figure of merit resulted to be 820.924 RIU−1. This SPR-PCF sensor offers high stability during operation due to its high linearity in the visible and infrared spectrum. The proposed sensor has the merits of an extremely wide range of RI detection with high sensitivity and a significantly improved polished design, which can be used in various applications, including chemical analysis, gas detection, and biological cell detection with extremely high accuracy.
11 September 2021 in arXiv
With the occupancy of the existing frequency spectrum the demands of the skyrocketing data traffic paved the path for 5G millimeter Wave (mmWave) technology. The wide frequency spectrum and high directivity can elevate the mean data rate. This performance gain comes at the cost of a higher pathloss which limits the use of mmWave technology to small cells. Also at such high frequencies the multipath components and blockages appear as persistent barriers leading to alteration of antenna polarization, affecting resource scheduler performance and throughput degradation. The impact of these barriers for high velocity user equipments (UEs) in mmWave network is still left to be studied. Using closed loop spatial multiplexing transmission scheme this study analyses the effect of receiver antenna polarization and types of resource scheduler used in base station on the downlink performance of mobile users (0-120kmph) in the mmWave small cell network. Thorough investigation has been conducted to infer which antenna combination should be advantageous under different scheduling algorithms for high mobility UEs. Our results indicate that the scheduler performance is complimented by the receiver antenna polarization, and by appropriate selection a better downlink performance can be sustained. Also reception under linear polarization performs better over circular polarization for high velocity UEs.