Caryn Hughes

Caryn Hughes

Auto-generated profile, based on publicly available information

Caryn Hughes

Manchester Interdisciplinary Biocentre, University of Manchester, 131 Princess Street, Manchester, UK M1 7DN

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2014 in Nature Protocols
Verified
Journal Article
Closed access
PDF file
Matthew J. BakerMatthew J. Baker
Matthew J. Baker
JTJúlio Trevisan
Júlio Trevisan
PBPaul Bassan
Paul Bassan
BRBhargava Rohit
Bhargava Rohit
HBHolly J Butler
Holly J Butler
FMFrancis L Martin
Francis L Martin

9 February 2012 in The Analyst
Verified
Journal Article
Closed access
PDF file
PBPaul Bassan
Paul Bassan
ASAshwin Sachdeva
Ashwin Sachdeva
AKAchim Kohler
Achim Kohler
CHCaryn Hughes
Caryn Hughes
AHAlex Henderson
Alex Henderson
PGPeter Gardner
Peter Gardner
Transmission and transflection infrared microscopy of biological cells and tissue suffer from significant baseline distortions due to scattering effects, predominantly resonant Mie scattering (RMieS). This scattering can also distort peak shapes and apparent peak positions making interpretation difficult and often unreliable. A correction algorithm, the resonant Mie scattering extended multiplicative signal correction (RMieS-EMSC), has been developed that can be used to remove these distortions. The correction algorithm has two key user defined parameters that influence the accuracy of the correction. The first is the number of iterations used to obtain the best outcome. The second is the choice of the initial reference spectrum required for the fitting procedure. The choice of these parameters influences computational time. This is not a major concern when correcting individual spectra or small data sets of a few hundred spectra but becomes much more significant when correcting spectra from infrared images obtained using large focal plane array detectors which may contain tens of thousands of spectra. In this paper we show that, classification of images from tissue can be achieved easily with a few (<10) iterations but a reliable interpretation of the biochemical differences between classes could require more iterations. Regarding the choice of reference spectrum, it is apparent that the more similar it is to the pure absorption spectrum of the sample, the fewer iterations required to obtain an accurate corrected spectrum. Importantly however, we show that using three different non-ideal reference spectra, the same unique correction solution can be obtained.

31 January 2014 in Journal of Biophotonics
Verified
Journal Article
Open access
PDF file
CHCaryn Hughes
Caryn Hughes
MBMichael David Brown
Michael David Brown
GCGraeme Clemens
Graeme Clemens
AHAlex Henderson
Alex Henderson
GMGeraldine Monjardez
Geraldine Monjardez
PGPeter Gardner
Peter Gardner
There are many approaches to measuring the infrared spectrum of a blood serum sample. Naturally, each approach will have both advantages and disadvantages. We report on the progress of the application of infrared spectroscopy in the field of blood serum analysis towards clinical application, with a focus on prostate cancer. In order to perform a high‐powered study with clinical relevance, choosing the most suitable approach must undergo careful consideration. We review the possibilities of using different sample preparation methods and speculate upon the potential pitfalls of both transmission and attenuated total reflectance (ATR) techniques.

10 January 2014 in Analytical Methods
Verified
Journal Article
Open access
PDF file
CHCaryn Hughes
Caryn Hughes
LGLydia Gaunt
Lydia Gaunt
MBMichael David Brown
Michael David Brown
NCNoel Clarke
Noel Clarke
PGPeter Gardner
Peter Gardner
The effectiveness of the solvents xylene and hexane as dewaxing agents, for the preparation of formalin-fixed paraffin-embedded (FFPE) clinical tissue sections is evaluated and a protocol suitable for infrared spectral pathology suggested.

10 February 2009 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
THTim J. Harvey
Tim J. Harvey
CHCaryn Hughes
Caryn Hughes
AWAndrew Ward
Andrew Ward
EFElsa Correia Faria
Elsa Correia Faria
AHAlex Henderson
Alex Henderson
PGPeter Gardner
Peter Gardner

1 January 2010 in The Analyst
Verified
Journal Article
Closed access
PDF file
CHCaryn Hughes
Caryn Hughes
MLMatthew Liew
Matthew Liew
ASAshwin Sachdeva
Ashwin Sachdeva
PBPaul Bassan
Paul Bassan
PDPaul Dumas
Paul Dumas
PGPeter Gardner
Peter Gardner
It is hypothesized that cells with stem cell-like properties may be influential in carcinogenesis, possessing the ability to self-renew, produce differentiated daughter cells and resist environmental or therapeutic injury. This has led to a surge in interest in identifying and characterizing the tumour initiating or cancer stem cell (CSC) with the aim of discovering novel diagnostic and prognostic markers and of understanding the basic biology with the ultimate aim of generating new therapeutic approaches and biomarkers. However, a major hurdle to this process has been the lack of a truly specific cancer stem cell biomarker allied to the rarity of these cells. This has led to problems in characterising these CSCs by traditional ‘-omic’ techniques. Using a renal carcinoma cell line model, we show that synchrotron radiation-Fourier transform infrared (SR-FTIR) spectroscopy is a suitable tool to measure discrete differences in the biochemistry of small numbers of single-cells. Using the chemometric techniques of Principal Component and Linear Discriminant Analysis (PCA and LDA) for multivariate reduction, biochemical differences between the cells from different sub-populations were evaluated. Results found lipid and phosphodiester vibrations to be particularly good discriminating markers in the spectra of these stem-like cells, relative to the more differentiated, proliferating cells that make up the majority of the cell population.