Mehmet Akif Sahin

Mehmet Akif Sahin

Auto-generated profile, based on publicly available information

Mehmet Akif Sahin

Control and Manipulation of Microscale Living Objects, Center for Translational Cancer Research (TranslaTUM), Munich Institute of Biomedical Engineering (MIBE), Munich Institute of Integrated Materials, Energy and Process Engineering (MEP), Department of Electrical Engineering, School of Computation, Information and Technology (CIT), Technical University of Munich (TUM), Einsteinstraße 25, Munich 81675, Germany

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2022 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MSMehmet Akif Sahin
Mehmet Akif Sahin
HWHelen Werner
Helen Werner
SUShreya Udani
Shreya Udani
DCDino Di Carlo
Dino Di Carlo
GDGhulam Destgeer
Ghulam Destgeer
This critical review presents flow lithography-based particle fabrication methods, describes fundamental physicochemical concepts, discusses applications of particles and highlights potential future research directions.

1 May 2025 in Biomicrofluidics
Verified
Journal Article
Closed access
MAMushtaq Ali
Mushtaq Ali
WKWoohyuk Kim
Woohyuk Kim
MKMuhammad Soban Khan
Muhammad Soban Khan
MSMehmet Akif Sahin
Mehmet Akif Sahin
GDGhulam Destgeer
Ghulam Destgeer
JPJinsoo Park
Jinsoo Park
Acoustofluidics, offering contact-free and precise manipulation of micro-objects, has emerged as a transformative tool for various biological and medical applications. In recent years, significant advancements have been made in droplet manipulation using acoustic waves. This review provides an in-depth exploration of acoustofluidic techniques for droplet manipulation, presenting a balanced perspective on the role of this versatile platform across diverse applications. The paper begins by introducing the underlying mechanism of acoustic forces acting on the droplets, followed by a comprehensive discussion of acoustofluidic techniques tailored for essential unit operations, such as droplet generation, separation, merging, splitting, steering, trapping, in-droplet sample manipulation, sample control within sessile droplets, and digital acoustofluidics. Finally, the prospects and limitations of acoustofluidics for droplet manipulations are also discussed, suggesting the future direction of droplet acoustofluidics research.

16 December 2019 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
MŞMehmet Akif Şahin
Mehmet Akif Şahin
BCBarbaros Cetin
Barbaros Cetin
MÖM. Bülent Özer
M. Bülent Özer

30 October 2024 in Advanced Science
Verified
Journal Article
Open access
JPJeongeun Park
Jeongeun Park
BCBeomseok Cha
Beomseok Cha
FAFurkan Ginaz Almus
Furkan Ginaz Almus
MSMehmet Akif Sahin
Mehmet Akif Sahin
HKHyochan Kang
Hyochan Kang
JPJinsoo Park
Jinsoo Park
Acoustofluidics is a promising technology that leverages acoustic waves for precise manipulation of micro/nano‐scale flows and suspended objects within microchannels. Despite many advantages, the practical applicability of conventional acoustofluidic platforms is limited by irreversible bonding between the piezoelectric actuator and the microfluidic chip. Recently, reconfigurable acoustofluidic platforms are enabled by reversible bonding between the reusable actuator and the replaceable polydimethylsiloxane (PDMS) microfluidic chip by incorporating a PDMS membrane for sealing the microchannel and coupling the acoustic waves with the fluid inside. However, a quantitative guideline for selecting a suitable PDMS membrane for various acoustofluidic applications is still missing. Here, a design rule for reconfigurable acoustofluidic platforms is explored based on a thorough investigation of the PDMS thickness effect on acoustofluidic phenomena: acousto–thermal heating (ATH), acoustic radiation force (ARF), and acoustic streaming flow (ASF). These findings suggest that the relative thickness of the PDMS membrane ( t ) for acoustic wavelength ( λ PDMS ) determines the wave attenuation in the PDMS and the acoustofluidic phenomena. For t / λ PDMS ≈ O(1), the transmission of acoustic waves through the membrane leads to the ARF and ASF phenomena, whereas, for t / λ PDMS ≈ O(10), the acoustic waves are entirely absorbed within the membrane, resulting in the ATH phenomenon.

20 April 2024 in Advanced Materials Technologies
Verified
Journal Article
Open access
MAMuhammad Usman Akhtar
Muhammad Usman Akhtar
MSMehmet Akif Sahin
Mehmet Akif Sahin
HWHelen Werner
Helen Werner
GDGhulam Destgeer
Ghulam Destgeer
Compartmentalizing an aqueous media into numerous nanoliter‐scale droplets has substantially improved the performance of amplification assays. Particle‐templated droplets or dropicles offer a user‐friendly workflow for creating uniform volume compartments upon simple mixing of reagents and particles using common laboratory apparatus. Amphiphilic shape‐coded particles are demonstrated to spontaneously hold aqueous droplets within hydrophilic cavities for multiplexed diagnostic assays. Here, a configurable 3D‐printed microfluidic device is proposed for the tunable fabrication of amphiphilic size‐coded particles. The device is configured with multiple outlet tubings of different diameters and photomasks of variable slit lengths to fabricate a wide range of size‐coded particles. a range of unique particle codes are fabricated using a single reconfigurable device. The cross‐sectional profile of the particles is further engineered by tuning the flow rate ratios of precursor streams to vary the inner and outer diameters of the particles and the thicknesses of the inner hydrophilic and outer hydrophobic layers. A range of cavity diameters and particle lengths enabled dropicle volumes of ≈1 nL to ≈30 nL. The fabricated particles are characterized by their ability to hold uniform droplet volumes and to orient themselves facing upward or sideways in a well plate based on their aspect ratios.

15 April 2025 in Advanced Materials Technologies
Verified
Journal Article
Open access
HWHelen Werner
Helen Werner
ETEbrahim TaiediNejad
Ebrahim TaiediNejad
MSMehmet Akif Sahin
Mehmet Akif Sahin
MLMoritz Leuthner
Moritz Leuthner
PEPeer Erfle
Peer Erfle
GDGhulam Destgeer
Ghulam Destgeer
Three different flow control methods are investigated to stop a multilayered flow inside a 3D‐printed microfluidic channel by bringing the average flow velocity from >100 mm s−1 to below a critical velocity of 200 µm s−1 within a certain delay time td of ≈2 s. A sequence of three concentric nozzles is 3D printed (≈75 µm) and embedded serially inside the microchannel (≈200 µm) using a two‐photon polymerization method. The 3D printed device produces a structured coaxial flow of four streams with individual layer thicknesses of O(10 µm). The pressure gradient across the fluidic circuit is removed, from > 2 bar to ≈0 bar, to stop the multilayered flow and measure td to assess the performance of the three stop‐flow methods. During the stop‐flow phase, an inhomogeneous pressure gradient across different inlets resulted in a backflow to inlet channels with lower pressures. The fluidic capacitance is systematically managed to minimize a dimensionless backflow index (BFI) value from ≈0.3 (worst case) to ≈0.03 (best case) for a total flow rate ranging from 16.8 to 168 µL min−1. Finally, the best stop‐flow conditions are recommended, which resulted in a minimal delay time of td ≈ 2 s and a BFI < 0.05.