Daphna Link-Sourani

Daphna Link-Sourani

Auto-generated profile, based on publicly available information

Daphna Link-Sourani

Department of Biomedical Engineering Technion—IIT Haifa Israel

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2023 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
BYBossmat Yehuda
Bossmat Yehuda
ARAviad Rabinowich
Aviad Rabinowich
DLDaphna Link-Sourani
Daphna Link-Sourani
NANetanell Avisdris
Netanell Avisdris
OBOri Ben-Zvi
Ori Ben-Zvi
DBDafna Ben Bashat
Dafna Ben Bashat
BACKGROUND AND PURPOSE: The current imaging assessment of fetal brain gyrification is performed qualitatively and subjectively using sonography and MR imaging. A few previous studies have suggested methods for quantification of fetal gyrification based on 3D reconstructed MR imaging, which requires unique data and is time-consuming. In this study, we aimed to develop an automatic pipeline for gyrification assessment based on routinely acquired fetal 2D MR imaging data, to quantify normal changes with gestation, and to measure differences in fetuses with lissencephaly and polymicrogyria compared with controls. MATERIALS AND METHODS: We included coronal T2-weighted MR imaging data of 162 fetuses retrospectively collected from 2 clinical sites: 134 controls, 12 with lissencephaly, 13 with polymicrogyria, and 3 with suspected lissencephaly based on sonography, yet with normal MR imaging diagnoses. Following brain segmentation, 5 gyrification parameters were calculated separately for each hemisphere on the basis of the area and ratio between the contours of the cerebrum and its convex hull. Seven machine learning classifiers were evaluated to differentiate control fetuses and fetuses with lissencephaly or polymicrogyria. RESULTS: In control fetuses, all parameters changed significantly with gestational age (P < .05). Compared with controls, fetuses with lissencephaly showed significant reductions in all gyrification parameters (P ≤ .02). Similarly, significant reductions were detected for fetuses with polymicrogyria in several parameters (P ≤ .001). The 3 suspected fetuses showed normal gyrification values, supporting the MR imaging diagnosis. An XGBoost-linear algorithm achieved the best results for classification between fetuses with lissencephaly and control fetuses (n = 32), with an area under the curve of 0.90 and a recall of 0.83. Similarly, a random forest classifier showed the best performance for classification of fetuses with polymicrogyria and control fetuses (n = 33), with an area under the curve of 0.84 and a recall of 0.62. CONCLUSIONS: This study presents a pipeline for automatic quantification of fetal brain gyrification and provides normal developmental curves from a large cohort. Our method significantly differentiated fetuses with lissencephaly and polymicrogyria, demonstrating lower gyrification values. The method can aid radiologic assessment, highlight fetuses at risk, and may improve early identification of fetuses with cortical malformations.

19 February 2025 in Medical Image Analysis
Verified
Journal Article
Closed access
EHEyal Hanania
Eyal Hanania
AZAdi Zehavi-Lenz
Adi Zehavi-Lenz
IVIlya Volovik
Ilya Volovik
DLDaphna Link-Sourani
Daphna Link-Sourani
Israel CohenIsrael Cohen
Israel Cohen
MFMoti Freiman
Moti Freiman

8 September 2022 in arXiv
Verified
Preprint
Open access
PDF file
NANetanell Avisdris
Netanell Avisdris
ARAviad Rabinowich
Aviad Rabinowich
DFDaniel Fridkin
Daniel Fridkin
AZAyala Zilberman
Ayala Zilberman
SLSapir Lazar
Sapir Lazar
LJLeo Joskowicz
Leo Joskowicz
Normal fetal adipose tissue (AT) development is essential for perinatal well-being. AT, or simply fat, stores energy in the form of lipids. Malnourishment may result in excessive or depleted adiposity. Although previous studies showed a correlation between the amount of AT and perinatal outcome, prenatal assessment of AT is limited by lacking quantitative methods. Using magnetic resonance imaging (MRI), 3D fat- and water-only images of the entire fetus can be obtained from two point Dixon images to enable AT lipid quantification. This paper is the first to present a methodology for developing a deep learning based method for fetal fat segmentation based on Dixon MRI. It optimizes radiologists' manual fetal fat delineation time to produce annotated training dataset. It consists of two steps: 1) model-based semi-automatic fetal fat segmentations, reviewed and corrected by a radiologist; 2) automatic fetal fat segmentation using DL networks trained on the resulting annotated dataset. Three DL networks were trained. We show a significant improvement in segmentation times (3:38 hours to < 1 hour) and observer variability (Dice of 0.738 to 0.906) compared to manual segmentation. Automatic segmentation of 24 test cases with the 3D Residual U-Net, nn-UNet and SWIN-UNetR transformer networks yields a mean Dice score of 0.863, 0.787 and 0.856, respectively. These results are better than the manual observer variability, and comparable to automatic adult and pediatric fat segmentation. A radiologist reviewed and corrected six new independent cases segmented using the best performing network, resulting in a Dice score of 0.961 and a significantly reduced correction time of 15:20 minutes. Using these novel segmentation methods and short MRI acquisition time, whole body subcutaneous lipids can be quantified for individual fetuses in the clinic and large-cohort research.

5 November 2026 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
MMMiriam Misochnik
Miriam Misochnik
AOAaron Olender
Aaron Olender
DSDana Schonberger
Dana Schonberger
YWYair Wexler
Yair Wexler
AZAyala Zilberman
Ayala Zilberman
ARAviad Rabinowich
Aviad Rabinowich
Background: Fetal growth restriction (FGR) may induce redistribution of the fetal circulation to preserve perfusion of vital organs. Reduced hepatic delivery of oxygen‐ and nutrient‐rich blood may cause volumetric and morphological remodeling. Purpose: To quantify fetal liver volume and morphology in FGR and assess associations with adverse neonatal outcomes. Study Type: Single‐center, prospective and retrospective. Population: Ninety‐two singleton pregnancies: 36 FGR cases (prospective) and 56 appropriate‐for‐gestational‐age (AGA) controls (retrospective). Field Strength/Sequence: 3‐T, True Fast Imaging with Steady‐State Free Precession (TrueFISP) for fetal liver and body imaging, and TrueFISP or Half‐Fourier Acquisition Single‐shot Turbo Spin‐Echo for brain imaging. Assessment: The fetal liver, body, and brain were segmented using deep learning tools. Liver volume, liver‐to‐body and brain‐to‐liver volume ratios, and 12 liver PyRadiomics shape features were assessed. Neonates were followed for composite adverse neonatal outcomes (CANO) until discharge. Statistical Tests: Linear regression assessed associations with gestational age in AGA fetuses. Linear mixed‐effects models compared groups, adjusting for gestational age and fetal sex. Univariable logistic regression assessed associations with CANO. Benjamini‐Hochberg correction controlled the false discovery rate at 0.05. Results: FGR fetuses had significantly lower liver volume than AGA fetuses (74.95 ± 1.76 vs. 114.89 ± 2.18 cm 3 ), lower liver‐to‐body ratio (0.053 ± 0.001 vs. 0.057 ± 0.001), and higher brain‐to‐liver ratio (2.637 ± 0.085 vs. 1.978 ± 0.047). FGR fetuses demonstrated significantly less elongated liver geometry, (10.7% higher PyRadiomics elongation values) and had a significantly higher surface‐to‐volume ratio (11.9%). CANO occurred in 30/92 neonates (27 FGR, 3 AGA). Higher brain‐to‐liver ratio (OR = 4.12, 95% CI: 1.93–8.77), PyRadiomics elongation values (less elongated geometry; OR = 2.04, 95% CI: 1.26–3.30), PyRadiomics flatness values (less flattened geometry; OR = 1.69, 95% CI: 1.07–2.65), and surface‐to‐volume ratio (OR = 3.26, 95% CI: 1.80–5.90) were significantly associated with CANO. Data Conclusion: FGR was associated with reduced fetal liver size and altered geometry, which were associated with neonatal morbidity. Evidence Level: 2. Technical Efficacy: 2.