Rajendra Dangol

Rajendra Dangol

Auto-generated profile, based on publicly available information

Rajendra Dangol

Unit Building Physics and Services, Eindhoven University of Technology, Eindhoven, the Netherlands

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2013 in Lighting Research & Technology
Verified
Journal Article
Closed access
RBRr Baniya
Rr Baniya
RDR Dangol
R Dangol
PBPramod Bhusal
Pramod Bhusal
AWA Wilm
A Wilm
EBE Baur
E Baur
LHL Halonen
L Halonen
In previous user-acceptance studies conducted at Aalto University, it was found that the preferred light-emitting diode spectral power distributions (SPDs) were not characterised by a high-CIE colour-rendering index but by a high-colour quality index (CQS) colour preference scale (Qp) and a high-CQS gamut area scale (Qg). In these studies, the SPDs were realised with a 12-channel LED spectra simulator. It is, however, foreseen that LED light sources consisting of 12 different types of LEDs will not be commercially exploitable due to complexity. The objective of this work was to investigate the possibility of generating simplified LED SPDs having CQS Qp and CQS Qg values similar to those of the preferred complex LED SPDs found in the previous user-acceptance studies. User-acceptance studies were carried out in lighting booths to investigate people’s preferences for the lit environment under both the complex and simplified LED spectra. The results suggest that the preferred complex LED SPDs can be optimized both for efficiency and cost without sacrificing the colour quality of the light.

9 October 2019 in Lighting Research & Technology
Verified
Journal Article
Open access
PDF file
TKTw Kruisselbrink
Tw Kruisselbrink
RDR Dangol
R Dangol
ARAlp Rosemann
Alp Rosemann
ELEj van Loenen
Ej van Loenen
Presently, luminance distribution measurement devices, using High Dynamic Range technology, are increasingly used as they provide a lot of relevant data related to the lit environment at once. However, the accuracy of these devices can be a concern. It is expected that the accuracy would be improved by incorporating the effect of the camera spectral responsivity and the spectral power distribution of the illuminant under which the measurements are conducted. This study introduces two optimization criteria incorporating these aspects to improve the spectral match and the performance of luminance distribution measurement devices. Both criteria are tested in a theoretical model and in practical measurements using two cameras and three illuminants: LED, halogen and fluorescent. Both methodologies support the hypothesis that the conventional method to determine the luminance introduces spectral mismatches that can be limited by optimizing relative to the spectral responsivity of the camera. Additionally, substantial evidence was found, by both the theoretical model and the validation measurements, that the spectral power distribution of the illuminant also has an effect on the performance.

5 August 2018
Verified
Book Chapter
Closed access
PDF file
TKThijs Kruisselbrink
Thijs Kruisselbrink
JDJuliette van Duijnhoven
Juliette van Duijnhoven
RDRajendra Dangol
Rajendra Dangol
ARAlexander Rosemann
Alexander Rosemann