Simon Hofstede

Simon Hofstede

Auto-generated profile, based on publicly available information

Simon Hofstede

Laboratory for Orthopaedic Biomechanics, Institute for Biomechanics, ETH Zurich, Lengghalde 5, 8008 Zurich, Switzerland

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
PBPaul Borbas
Paul Borbas
MVMaximilian Vetter
Maximilian Vetter
RLRafael Loucas
Rafael Loucas
SHSimon Hofstede
Simon Hofstede
KWKarl Wieser
Karl Wieser
LELukas Ernstbrunner
Lukas Ernstbrunner

10 January 2023 in Acta Biomaterialia
Verified
Journal Article
Open access
NPN. Poulis
N. Poulis
PBP. Breitenstein
P. Breitenstein
SHS. Hofstede
S. Hofstede
SHS.P. Hoerstrup
S.P. Hoerstrup
MEMaximilian Y. Emmert
Maximilian Y. Emmert
EFE.S. Fioretta
E.S. Fioretta
Human tissue-engineered matrices (hTEMs) have been proposed as a promising approach for in situ tissue engineered heart valves (TEHVs). However, there is still a limited understanding on how ECM composition in hTEMs develops over tissue culture time. Therefore, we performed a longitudinal hTEM assessment by 1) multiscale evaluation of hTEM composition during culture time (2, 4, 6-weeks), using (immuno)histology, biochemical assays, and mass spectrometry (LC-MS/MS); 2) analysis of protein pathways involved in ECM development using gene set enrichment analysis (GSEA); and 3) assessment of hTEM mechanical characterization using uniaxial tensile testing. Finally, as a proof-of-concept, TEHVs manufactured using 6-weeks hTEM samples were tested in a pulse duplicator. LC-MS/MS confirmed the tissue culture time-dependent increase in ECM proteins observed in histology and biochemical assays, revealing the most abundant collagens (COL6, COL12), proteoglycans (HSPG2, VCAN), and glycoproteins (FN, TNC). GSEA identified the most represented protein pathways in the hTEM at 2-weeks (mRNA metabolic processes), 4-weeks (ECM production), and 6-weeks (ECM organization and maturation). Uniaxial mechanical testing showed increased stiffness and stress at failure, and reduction in strain over tissue culture time. hTEM-based TEHVs demonstrated promising in vitro performance at both pulmonary and aortic pressure conditions, with symmetric leaflet coaptation and no stenosis. In conclusion, ECM protein abundance and maturation increased over tissue culture time, with consequent improvement of hTEM mechanical characteristics. These findings suggest that longer tissue culture impacts tissue organization, leading to an hTEM that may be suitable for high-pressure applications. STATEMENT OF SIGNIFICANCE: It is believed that the composition of the extracellular matrix (ECM) in the human tissue engineered matrices (hTEM) may favor tissue engineered heart valve (TEHV) remodeling upon implantation. However, the exact protein composition of the hTEM, and how this impacts tissue mechanical properties, remains unclear. Hence, we developed a reproducible rotation-based tissue culture method to produce hTEM samples. We performed a longitudinal assessment using different analytical techniques and mass spectrometry. Our data provided an in-depth characterization of the hTEM proteome with focus on ECM components, their development, and how they may impact the mechanical properties. Based on these results, we manufactured functional hTEM-based TEHVs at aortic-like condition in vitro. These outcomes pose an important step in translating hTEM-based TEHVs into clinics and in predicting their remodeling potential upon implantation.

24 September 2021 in JSES International
Verified
Journal Article
Open access
CLChristoph J. Laux
Christoph J. Laux
PBPaul Borbas
Paul Borbas
CVChristina Villefort
Christina Villefort
SHSimon Hofstede
Simon Hofstede
LELukas Ernstbrunner
Lukas Ernstbrunner
KWKarl Wieser
Karl Wieser
The need for coracoclavicular (CC) stabilization in the fixation of fractures with CC instability (Neer type IIB and V) was biomechanically demonstrated by higher construct strength than isolated locking plate osteosynthesis. It was the purpose of this study to prove noninferiority of the new cow-hitch suture repair technique compared with the well-established suture tape double-button fixation with regard to overall fixation strength and cyclic loading properties. Twelve human cadaver shoulders (7 right and 5 left) were matched for sex and age (mean age: 75 ± 5 years). An oblique parasagittal fracture line 20 mm medial to the acromioclavicular joint line was created, and the CC ligaments were dissected. Six shoulders were reconstructed by a double FiberTape fixation with two suture buttons (group DB), and the remaining six shoulders by a cow-hitch suture repair using a double FiberWire with only coracoid button fixation (group CH). Both reconstruction techniques were tested in a servo-hydraulic material testing machine for cyclic displacement (mm), stiffness (N/mm), and maximum load-to-failure (N) after 500 cycles at 3 mm/s and inferosuperior load between 15 and 70 N. Superior fragment displacement in space was recorded using a MicroScribe digitizer. There were no statistically significant differences regarding cyclic displacement (group DB: 0.7 mm; group CH: 1.3 mm; P = .36), stiffness (group DB: 177 N/mm; group CH: 116 N/mm; P = .17), maximum load-to-failure (group DB: 560 N; group CH: 492 N; P = .59), and superior displacement in space of the medial fragment (group DB: 3.2 mm; group CH: 1.6 mm; P = .48). Fixation of unstable distal clavicle fractures using a double FiberWire cow-hitch suture repair with isolated coracoid button fixation for stand-alone CC stabilization resulted in similar biomechanical properties to a double-suture button fixation with FiberTapes while avoiding prominent clavicular implants.