20 January 2020 in IEEE/ASME Transactions on Mechatronics
Endoscopy is often used to treat hydrocephalus, a common pediatric neurosurgical condition. Rigid endoscopic tools used in these procedures have many limitations. In this article, we propose four novel designs for a steerable two degree-of-freedom robotic tool body to be deployed through a rigid endoscope and a handheld controller for such a tool body. Each of these designs make use of tendon-driven joints known as asymmetric notch joints, while varying tendon routing techniques. Furthermore, we design a compact handheld controller for this steerable tool body, which consists of dc motors driving lead screws to actuate the tendons for each of the robot's joints. A disturbance observer-based control system for these motors is designed to allow the motor to reach the desired tendon displacements under various loading conditions. Next, we analyze the kinematics of the bidirectional asymmetric notch joint, deriving a relationship between the joint angle and corresponding tendon displacement. Finally, we test each of our four proposed designs for interjoint coupling and provide some insights into the results of our tests. We find that tendon routing strategies play an important role in minimizing tendon coupling for meso-scale continuum tendon-driven robots and combining the properties of each of these asymmetric joints can prove to be beneficial in improving the performance of such two degree-of-freedom robots.
28 January 2020 in IEEE Robotics and Automation Letters
Endovascular and endoscopic surgical procedures require micro-scale and meso-scale continuum robotic tools to navigate complex anatomical structures. In numerous studies, fiber Bragg grating (FBG) based shape sensing has been used for measuring the deflection of continuum robots on larger scales, but has proved to be a challenge for micro-scale and meso-scale robots with large deflections. In this letter, we have developed a sensor by mounting an FBG fiber within a micromachined nitinol tube whose neutral axis is shifted to one side due to the machining. This shifting of the neutral axis allows the FBG core to experience compressive strain when the tube bends. The fabrication method of the sensor has been explicitly detailed and the sensor has been tested with two tendon-driven micro-scale and meso-scale continuum robots with outer diameters of 0.41 mm and 1.93 mm respectively. The compact sensor allows repeatable and reliable estimates of the shape of both scales of robots with minimal hysteresis. We propose an analytical model to derive the curvature of the robot joints from FBG fiber strain and a static model that relates joint curvature to the tendon force. Finally, as proof-of-concept, we demonstrate the feasibility of our sensor assembly by combining tendon force feedback and the FBG strain feedback to generate reliable estimates of joint angles for the meso-scale robot.
13 April 2023 in IEEE Robotics and Automation Letters
Placement of catheters in minimally invasive cardiovascular procedures is preceded by navigating to the target lesion with a guidewire. Traversing through tortuous vascular pathways can be challenging without precise tip control, potentially resulting in the damage or perforation of blood vessels. To improve guidewire navigation, this letter presents 3D shape reconstruction and tip force sensing for the COaxially Aligned STeerable (COAST) guidewire robot using a triplet of adhered single core fiber Bragg grating sensors routed centrally through the robot's slender structure. Additionally, several shape reconstruction algorithms are compared, and shape measurements are utilized to enable tip force sensing. Demonstration of the capabilities of the robot is shown in free air where the shape of the robot is reconstructed with average errors less than 2 mm at the guidewire tip, and the magnitudes of forces applied to the tip are estimated with an RMSE of 0.027 N or less.
24 February 2023 in IEEE/ASME Transactions on Mechatronics
Continuum manipulators contribute to promising improvements of minimally invasive surgical procedures due to their compliance, small size, and ability to navigate anatomical pathways. Feedback of the shape of such robots within the body is currently being researched through the use of fiber Bragg grating (FBG) sensors. As the size of the robot is reduced, placement of the sensors becomes increasingly challenging, often relying on glues and epoxies. In this article, a triplet of FBG fibers is used for shape sensing of a tendon driven continuum joint. Tests are performed to show the accuracy of reconstruction using this sensor both alone and incorporated in a tendon-driven continuum joint. A repeatable sensor drift was observed during prolonged deflection which caused an increase in error of up to 0.218 mm over a 10-min period. Results showed the effect of the repeated and sustained deflection on shape reconstruction under various deflection conditions and temperatures.
14 June 2023 in IEEE Robotics and Automation Letters
Minimally invasive endovascular procedures involve the manual placement of a guidewire, which is made difficult by vascular tortuosity and the lack of precise tip control. Steerable guidewire systems have been developed with tendon-driven, magnetic, and concentric tube actuation strategies to enable precise tip control, however, selecting machining parameters for such robots does not have a strict procedure. In this letter, we develop a systematic design procedure for selecting the tube pairs of the CO axially A ligned ST eerable (COAST) guidewire robot. This includes the introduction of a mechanical model that accounts for micromachining-induced pre-curvatures with the goal of determining design parameters that reduce combined distal tip pre-curvature and minimize abrupt changes in actuated tip position for the COAST guidewire robot through selection of the best flexural rigidity between the tube pairs. We present adjustments in the kinematics modeling of COAST robot tip bending motion, and use these to characterize the bending behavior of the COAST robot for varying geometries of the micromachined tubes, with an average RMSE value for the tip position error of 0.816 mm in the validation study.
18 January 2023 in IEEE Transactions on Medical Robotics and Bionics
Steerable needles are desired for many applications within the medical field. One such application is high-dose rate (HDR) brachytherapy. In this paper, an adaptive control system is proposed to provide control of the planar bending angle or deflection distance of a tendon-driven continuum joint, which can be inserted as the stylet in a commercial hollow needle for HDR brachytherapy. Proportional–integral–derivative (PID) controllers are a common method of control. However, significant tuning may be required to achieve the desired dynamic response, and the tuned gains may not achieve the desired response in a different environment or if the system model varies. Steerable needles must navigate through tissues of differing viscoelastic properties and the use of nitinol for the joint and tendons of a steerable needle leads to change in the system parameters due to change in the phase of the nitinol material. In this article, we propose the real-time adaptation of PID gains using model reference adaptive control techniques to control the planar bending angle or deflection distance of a steerable stylet and needle system.