Jaydev P. Desai

Jaydev P. Desai

Auto-generated profile, based on publicly available information

Jaydev P. Desai

Wallace H. Coulter Department of Biomedical Engineering, Medical Robotics and Automation (RoboMed) Laboratory, Georgia Institute of Technology, Atlanta, GA, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
JZJun Zhang
Jun Zhang
JSJun Sheng
Jun Sheng
COCiaran T. O'NEill
Ciaran T. O'NEill
CWConor J. Walsh
Conor J. Walsh
RWRobert Wood
Robert Wood
MYMichael C. Yip
Michael C. Yip
Robotic artificial muscles are a subset of artificial muscles that are capable of producing biologically inspired motions useful for robot systems, i.e., large power-to-weight ratios, inherent compliance, and large range of motions. These actuators, ranging from shape memory alloys to dielectric elastomers, are increasingly popular for biomimetic robots as they may operate without using complex linkage designs or other cumbersome mechanisms. Recent achievements in fabrication, modeling, and control methods have significantly contributed to their potential utilization in a wide range of applications. However, no survey paper has gone into depth regarding considerations pertaining to their selection, design, and usage in generating biomimetic motions. In this paper, we discuss important characteristics and considerations in the selection, design, and implementation of various prominent and unique robotic artificial muscles for biomimetic robots, and provide perspectives on next-generation muscle-powered robots.

3 May 2022 in Proceedings of the IEEE
Verified
Journal Article
Open access
Hao SuHao Su
Hao Su
Ka Wai KwokKa Wai Kwok
Ka Wai Kwok
KCKevin Cleary
Kevin Cleary
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
MCM. Cenk Cavusoglu
M. Cenk Cavusoglu
GFGregory S. Fischer
Gregory S. Fischer
Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of target anatomy, surrounding tissue, and instrumentation, but there are significant challenges in harnessing it for effectively guiding interventional procedures. Challenges include the strong static magnetic field, rapidly switching magnetic field gradients, high-power radio frequency pulses, sensitivity to electrical noise, and constrained space to operate within the bore of the scanner. MRI has a number of advantages over other medical imaging modalities, including no ionizing radiation, excellent soft-tissue contrast that allows for visualization of tumors and other features that are not readily visible by other modalities, true 3-D imaging capabilities, including the ability to image arbitrary scan plane geometry or perform volumetric imaging, and capability for multimodality sensing, including diffusion, dynamic contrast, blood flow, blood oxygenation, temperature, and tracking of biomarkers. The use of robotic assistants within the MRI bore, alongside the patient during imaging, enables intraoperative MR imaging (iMRI) to guide a surgical intervention in a closed-loop fashion that can include tracking of tissue deformation and target motion, localization of instrumentation, and monitoring of therapy delivery. With the ever-expanding clinical use of MRI, MRI-compatible robotic systems have been heralded as a new approach to assist interventional procedures to allow physicians to treat patients more accurately and effectively. Deploying robotic systems inside the bore synergizes the visual capability of MRI and the manipulation capability of robotic assistance, resulting in a closed-loop surgery architecture. This article details the challenges and history of robotic systems intended to operate in an MRI environment and outlines promising clinical applications and associated state-of-the-art MRI-compatible robotic systems and technology for making this possible.

1 August 2021 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
PTPhillip Tran
Phillip Tran
SJSeokhwan Jeong
Seokhwan Jeong
KHKinsey R. Herrin
Kinsey R. Herrin
JDJaydev P. Desai
Jaydev P. Desai
Spinal cord injury (SCI) and stroke are pathologies that often result in the loss of/decrease in hand functionality. Hand function is a critical component of everyday life and therefore, a primary focus of clinical SCI/stroke rehabilitation is hand function recovery/improvement. In recent years, there has been a surge in hand exoskeleton research due to the potential for exoskeletons to improve clinical rehabilitation efficiency through automation. However, there is a disconnect between current clinical practice and exoskeleton research, resulting in a minority of hand exoskeletons being tested on individuals with SCI and/or stroke. This review article provides a comprehensive analysis and review of hand exoskeleton studies based on clinical rehabilitation practices to bridge the knowledge gap between clinical application and laboratory research. The key findings from this paper are: 1) current hand exoskeletons can successfully complete simple ADL tasks but lack the precision for fine motor control, 2) most hand exoskeletons exhibit a low number of degrees-of-freedom compared to the human hand, which may limit movement capability, 3) the majority of hand exoskeletons lack sensing capabilities, restricting viable control methods and user interfaces, and 4) inconsistent evaluation methods across studies do not allow for accurate performance assessment for different exoskeletons. The comparative assessments performed by this survey article show that there remain deficits between clinical hand rehabilitation practices and the current state of hand exoskeletons. By delineating these shortcomings, the information presented in this work can help inform future developments in the field of assistive and rehabilitative hand exoskeletons such that the gap between research and application may be closed.

4 November 2020 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
YCYash Chitalia
Yash Chitalia
SJSeokhwan Jeong
Seokhwan Jeong
KYKent K. Yamamoto
Kent K. Yamamoto
JCJoshua J. Chern
Joshua J. Chern
JDJaydev P. Desai
Jaydev P. Desai
This article introduces the analysis and control of a meso-scale two degree-of-freedom robotic endoscopic tool body for minimally invasive surgeries. The design of the robotic tool uses two types of a tendon-driven joint known as a bending flexure joint that allows us to control each degree-of-freedom by minimizing interjoint coupling by design. Pure kinematic modeling and control for these robots may not provide precise control performance due to kinematic uncertainties arising from tendon elongation, tendon slacking, gear backlash, etc. We propose a static model for each of the joints of the robotic tool that avoids several of these problems. Depending on the direction of tendon tension application, the proximal joint displays considerable hysteresis due to the superelastic material characteristics and this is included in our static model. The statics of a highly compliant distal joint is also modeled and validated using finite element analysis and experimental data. Using these models, we develop a control system that comprises of a disturbance observer and the proposed static model to provide precise force control and compensate for joint hysteresis.

25 June 2020 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
SJSeokhwan Jeong
Seokhwan Jeong
YCYash Chitalia
Yash Chitalia
JDJaydev P. Desai
Jaydev P. Desai
Manual navigation of a guidewire is the first step in endovascular interventions. However, this procedure is time consuming with uncertain results due to tortuous vascular anatomy. This letter introduces the design of a novel COaxially Aligned STeerable (COAST) guidewire robot that is 0.40 mm in diameter demonstrating variable curvature and independently controlled bending length of the distal end. The COAST design involves three coaxially aligned tubes with a single tendon running centrally through the length of robot. The outer tubes are made from micromachined nitinol allowing for tendon-driven bending of the robot at various segments of the robot, thereby enabling variable bending curvatures, while an inner stainless steel tube controls the bending length of the robot. By varying relative positions of the tubes and the tendon by insertion and retraction in the entire assembly, various joint lengths and curvatures can be achieved, which enables a follow-the-leader motion. We model the kinematics, statics, as well as the coupling within tubes of the COAST robot and develop a simple controller to control the distal tip of the robot. Finally, we experimentally demonstrate the ability of COAST guidewire to accurately navigate through phantom anatomical bifurcations and tortuous anatomy.

20 January 2020 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
YCYash Chitalia
Yash Chitalia
SJSeokhwan Jeong
Seokhwan Jeong
NDNancy Deaton
Nancy Deaton
JCJoshua J. Chern
Joshua J. Chern
JDJaydev P. Desai
Jaydev P. Desai
Endoscopy is often used to treat hydrocephalus, a common pediatric neurosurgical condition. Rigid endoscopic tools used in these procedures have many limitations. In this article, we propose four novel designs for a steerable two degree-of-freedom robotic tool body to be deployed through a rigid endoscope and a handheld controller for such a tool body. Each of these designs make use of tendon-driven joints known as asymmetric notch joints, while varying tendon routing techniques. Furthermore, we design a compact handheld controller for this steerable tool body, which consists of dc motors driving lead screws to actuate the tendons for each of the robot's joints. A disturbance observer-based control system for these motors is designed to allow the motor to reach the desired tendon displacements under various loading conditions. Next, we analyze the kinematics of the bidirectional asymmetric notch joint, deriving a relationship between the joint angle and corresponding tendon displacement. Finally, we test each of our four proposed designs for interjoint coupling and provide some insights into the results of our tests. We find that tendon routing strategies play an important role in minimizing tendon coupling for meso-scale continuum tendon-driven robots and combining the properties of each of these asymmetric joints can prove to be beneficial in improving the performance of such two degree-of-freedom robots.