Christian Schömers

Christian Schömers

Auto-generated profile, based on publicly available information

Christian Schömers

Heidelberg Ion-Beam Therapy Center (HIT)

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2020 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
LVLennart Volz
Lennart Volz
LKLaurent Kelleter
Laurent Kelleter
SBStephan Brons
Stephan Brons
LBLucas N Burigo
Lucas N Burigo
CGChristian Graeff
Christian Graeff
Joao SecoJoao Seco
Joao Seco
Recently, it has been proposed that a mixed helium/carbon beam could be used for online monitoring in carbon ion beam therapy. Fully stripped, the two ion species exhibit approximately the same mass/charge ratio and hence could potentially be accelerated simultaneously in a synchrotron to the same energy per nucleon. At the same energy per nucleon, helium ions have about three times the range of carbon ions, which could allow for simultaneous use of the carbon ion beam for treatment and the helium ion beam for imaging. In this work, measurements and simulations of PMMA phantoms as well as anthropomorphic phantoms irradiated sequentially with a helium ion and a carbon ion beam at equal energy per nucleon are presented. The range of the primary helium ion beam and the fragment tail of the carbon ion beam exiting the phantoms were detected using a novel range telescope made of thin plastic scintillator sheets read out by a flat-panel CMOS sensor. A 10:1 carbon to helium mixing ratio is used, generating a helium signal well above the carbon fragment background while adding little to the dose delivered to the patient. The range modulation of a narrow air gap of 1 mm thickness in the PMMA phantom that affects less than a quarter of the particles in a pencil beam were detected, demonstrating the achievable relative sensitivity of the presented method. Using two anthropomorphic pelvis phantoms it is shown that small rotations of the phantom as well as simulated bowel gas movements cause detectable changes in the helium/carbon beam exiting the phantom. The future prospects and limitations of the helium/carbon mixing as well as its technical feasibility are discussed.

29 April 2022 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
PDF file
SMStewart Mein
Stewart Mein
TTThomas Tessonnier
Thomas Tessonnier
BKBenedikt Kopp
Benedikt Kopp
CSChristian Schömers
Christian Schömers
Semi B HarrabiSemi B Harrabi
Semi B Harrabi
AMAndrea Mairani
Andrea Mairani

8 July 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
EGE.C. Cortés García
E.C. Cortés García
EFE. Feldmeier
E. Feldmeier
MGM. Galonska
M. Galonska
CSC. Schömers
C. Schömers
MHM. Hun
M. Hun
THTh. Haberer
Th. Haberer

24 February 2026 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PNPhilipp Niedermayer
Philipp Niedermayer
Rahul SinghRahul Singh
Rahul Singh
EFEike Feldmeier
Eike Feldmeier
CSChristian Schömers
Christian Schömers
MHMarcel Hun
Marcel Hun
Radio frequency knock out resonant slow extraction is a standard method for extracting stored particle beams from synchrotrons by transverse excitation. Excitation signals comprising many betatron sidebands have been shown to reduce intensity fluctuations of the extracted beam spill and are used at several facilities. In this contribution, the effect of individual sidebands at different harmonics on the spill quality is systematically studied using efficient noise excitation signals fully covering the respective sidebands. Particle tracking simulations show a clear correlation between the chosen excitation frequency and the spill quality. This relation is attributed to the spectrum of particle motion shortly before their extraction, and an empirical relation between the spectrum, the excitation frequency, and the resulting spill quality is given. Experiments show an additional reduction of pileup when using higher excitation frequencies. These insights have implications for an optimal design of excitation waveforms and hardware for knock out extraction systems.