Soheil Kavian

Soheil Kavian

Auto-generated profile, based on publicly available information

Soheil Kavian

Department of Mechanical Engineering, Science and Research Branch Islamic Azad University Tehran Iran

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in Applied Energy
Verified
Journal Article
Closed access
SKSoheil Kavian
Soheil Kavian
CACyrus Aghanajafi
Cyrus Aghanajafi
HMHassan Jafari Mosleh
Hassan Jafari Mosleh
ANArash Nazari
Arash Nazari
ANAshkan Nazari
Ashkan Nazari

1 October 2019 in Energy Conversion and Management
Verified
Journal Article
Closed access
SKSoheil Kavian
Soheil Kavian
CACyrus Aghanajafi
Cyrus Aghanajafi
NDNader Dizadji
Nader Dizadji

25 September 2020 in Energy Science & Engineering
Verified
Journal Article
Open access
PDF file
MZMohammad Hossein Zolfagharnasab
Mohammad Hossein Zolfagharnasab
CACyrus Aghanajafi
Cyrus Aghanajafi
SKSoheil Kavian
Soheil Kavian
NHNiloufar Heydarian
Niloufar Heydarian
MAMohammad Hossein Ahmadi
Mohammad Hossein Ahmadi
Nowadays, the low efficiency of solar energy power plant systems brings about uneconomical performance and high‐cost uncompetitive industries compared with the traditional fossil fuel ones. In order to overcome these kinds of issues, in this study, the performance of a solar tower coupled with a Rankine cycle is scrutinized using the first and second laws of thermodynamic. Moreover, a numerical code has been developed in the GNU Octave software environment to calculate the precise value for both energy and exergy losses of each component. Furthermore, the sensitivity analysis approach corresponds to the variation of several inner parameters such as direct normal irradiation (DNI), molten salt outlet temperature (MSOT), and the molten salt velocity (MSV), environmental parameters such as wind speed and ambient temperature have been performed. In addition, the overall losses are calculated by considering all possible forms of losses such as convection, conduction, reflection, and emission, and also, the portion of each source of these losses are determined. The obtained results indicate that the maximum exergy loss occurs in the central receiver system (CRS), while the major energy loss occurs in the turbine located in the power block. The sensitivity analysis shows that the rise of DNI significantly increases the exergy%energy efficiency of the cycle and also, the portion of loss related to emission heat transfer would be enhanced. Moreover, the variation of the MSV and MSOT illustrate influencing the performance of the cycle; consequently, the MSOT changes demonstrate a reverse relation with energy and direct relation with exergy efficiency. Accordingly, an optimum value of 650K is calculated for the MSOT as well as an optimum value of 2 m%s for the MSV. The environmental sensitivity analysis indicates that the enhancement of wind speed and ambient temperature has a negative impact on the net output of the cycle, which is not desirable.

12 June 2020 in Journal of Energy Resources Technology
Verified
Journal Article
Closed access
PDF file
ANArash Nazari
Arash Nazari
SKSoheil Kavian
Soheil Kavian
Ashkan NazariAshkan Nazari
Ashkan Nazari

18 February 2021 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
ARAlireza Riahi
Alireza Riahi
SKSoheil Kavian
Soheil Kavian
HMHassan Jafari Mosleh
Hassan Jafari Mosleh
MSMohammad Behshad Shafii
Mohammad Behshad Shafii

17 June 2020 in Energy Science & Engineering
Verified
Journal Article
Open access
PDF file
SSSeyedali Sabzpoushan
Seyedali Sabzpoushan
HMHassan Jafari Mosleh
Hassan Jafari Mosleh
SKSoheil Kavian
Soheil Kavian
Mohsen Saffari PourMohsen Saffari Pour
Mohsen Saffari Pour
OMOmid Mohammadi
Omid Mohammadi
MAMohammad Hossein Ahmadi
Mohammad Hossein Ahmadi
In this research, it is investigated to numerically evaluate the performance of a polymer electrolyte membrane fuel cell (PEMFC). The performance is investigated through the nonuniformity gradient loading at the catalyst layer (CL) of the considered PEMFC. Computational fluid dynamics is used to simulate a 2D domain in which a steady‐state laminar compressible flow in two‐phase for the PEMFC has been considered. In this case, a particular nonuniform variation inside the CL along the channel is assumed. The nonuniform gradient is created using a nonisothermal domain to predict the flooding effects on the performance of the PEMFC. The computational domain is considered as the cathode of PEMFC, which is divided into three regions: a gas channel, a gas diffusion layer, and a CL. The loading variation inside the catalyst is defined as a constant slope along the channel. In order to find the optimum slope, different slope angles are analyzed. The results point out that the nonuniform loading distribution of the catalyst (platinum) along the channel could improve the fuel cell performance up to 1.6% and 5% for power density and voltage generation, respectively. It is inferred that it is better to use more catalyst in the final section of the channel if the performance is the main concern.