Área de Investigación e Instrumentación Atmosférica, Instituto Nacional de Técnica Aeroespacial (INTA), El Arenosillo, Huelva, Spain

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2023 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
CGC. González
C. González
JVJ. M. Vilaplana
J. M. Vilaplana
APAntonio Serrano Pérez
Antonio Serrano Pérez
Precise spectral ultraviolet (UV) measurements are needed to ensure human protection as well as to support scientific research. Quantifying the uncertainty of the UV spectra recorded is crucial to evaluate the quality of the measurements which is needed, in turn, for the assessment of their reliability. However, for double‐monochromator spectroradiometers, the analytical derivation of this uncertainty is a challenging task due to the difficulties involved in propagating individual uncertainties. Under these circumstances, a Monte Carlo simulation is a reliable alternative as it does not require the calculation of partial derivatives and considers both nonlinear effects and correlations in the data. In the present study, the uncertainty of the spectral UV irradiance measured by a Brewer MKIII spectrophotometer is evaluated using a Monte Carlo approach. This instrument belongs to the National Institute of Aerospace Technology and has successfully participated in several international campaigns, which ensures its precise calibration. The average expanded uncertainty (k = 2) of the global UV irradiance measured by this instrument varies between 10% at 300 nm and 7% at 363 nm. At shorter wavelengths, it increases sharply due to thermal and electronic noise as well as wavelength misalignment. The results indicate that a Brewer spectrophotometer is suitable for climatological studies and model validation. Nevertheless, a substantial reduction of these uncertainties might be required for accurately detecting long‐term UV trends. Although the study focused on a Brewer spectrometer, the methodology used for the uncertainty analysis is general and can be adapted to most UV spectroradiometers.

15 July 2022 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
CGCarmen González
Carmen González
JVJosé M. Vilaplana
José M. Vilaplana
JBJosé A. Bogeat
José A. Bogeat
APAntonio Serrano Pérez
Antonio Serrano Pérez
Spectral measurements of UV irradiance are of great importance for protecting human health as well as for supporting scientific research. To perform these measurements, double monochromator scanning spectroradiometers are the preferred devices thanks to their linearity and stray-light reduction. However, because of their high cost and demanding maintenance, CCD-array-based spectroradiometers are increasingly used for monitoring UV irradiance. Nevertheless, CCD-array spectroradiometers have specific limitations, such as a high detection threshold or stray-light contamination. To overcome these challenges, several manufacturers are striving to develop improved instrumentation. In particular, Gigahertz-Optik GmbH has developed the stray-light-reduced BTS2048-UV-S spectroradiometer series (hereafter “BTS”). In this study, the long-term performance of the BTS and its seasonal behavior, regarding global UV irradiance, was assessed. To carry out the analysis, BTS irradiance measurements were compared against measurements from the Brewer MK-III #150 scanning spectrophotometer during three campaigns. A total of 711 simultaneous spectra, measured under cloud-free conditions and covering a wide range of solar zenith angles (SZAs; from 14 to 70∘) and UV indexes (from 2.4 to 10.6), were used for the comparison. During the three measurement campaigns, the global UV spectral ratio BTS / Brewer was almost constant (at around 0.93) in the 305–360 nm region for SZAs below 70∘. Thus, the BTS calibration was stable during the whole period of study (∼ 1.5 years). Likewise, it showed no significant seasonal or SZA dependence in this wavelength region. Regarding the UV index, a good correlation between the BTS and the Brewer #150 was found, i.e., the dynamic range of the BTS is comparable to that of the Brewer #150. These results confirm the quality of the long-term performance of the BTS array spectroradiometer in measuring global UV irradiance.

18 June 2025
Verified
Other
Open access
PDF file
CHCarmen González Hernández
Carmen González Hernández
Brewer spectroradiometers are robust, widely used instruments that have been monitoring global solar ultraviolet (UV) irradiance since the 1990s, playing a key role in solar UV research. Unfortunately, the uncertainties of these measurements are rarely evaluated due to the difficulties involved in the uncertainty propagation. This evaluation is essential to determine the quality of the measurements as well as their comparability to other measurements. In this study, eight double- and two single-monochromator Brewers are characterised and the uncertainty of their global UV measurements is estimated using the Monte Carlo method. This methodology is selected as it provides reliable uncertainty estimations and considers the nonlinearity of the UV processing algorithm. The combined standard uncertainty depends on the Brewer, varying between 2.5 % and 4 % for the 300–350 nm region. For wavelengths below 300 nm, the differences between single- and double-monochromator Brewers increase, due to stray light and dark counts. For example, at 295 nm, the relative uncertainties of single Brewers range between 11–14 % while double Brewers have uncertainties of 4–7 %. These uncertainties arise primarily from radiometric stability, the application of cosine correction, and the irradiance of the lamp used during the instrument calibration. As the intensity of the UV irradiance measured decreases, dark counts, stray light (for single Brewers), and noise become the dominant sources of uncertainty. These results indicate that the overall uncertainty of a Brewer spectroradiometer could be greatly reduced by increasing the frequency of radiometric calibration and improving the traditional entrance optics.

3 December 2023
Verified
Preprint
Open access
PDF file
CGCarmen González
Carmen González
JVJosé M. Vilaplana
José M. Vilaplana
ASAntonio Serrano
Antonio Serrano
A document by Carmen González Hernández. Click on the document to view its contents.

6 May 2025
Verified
Other
Open access
PDF file
CGCarmen González
Carmen González
JVJosé Manuel Vilaplana
José Manuel Vilaplana
ARAlberto Redondas
Alberto Redondas
JLJavier López-Solano
Javier López-Solano
JAJosé María San Atanasio
José María San Atanasio
APAntonio Serrano Pérez
Antonio Serrano Pérez
Brewer spectroradiometers are robust, widely used instruments that have been monitoring global solar ultraviolet (UV) irradiance since the 1990s, playing a key role in solar UV research. Unfortunately, the uncertainties of these measurements are rarely evaluated due to the difficulties involved in the uncertainty propagation. This evaluation is essential to determine the quality of the measurements as well as their comparability to other measurements. In this study, eight double- and two single-monochromator Brewers are characterised and the uncertainty of their global UV measurements is estimated using the Monte Carlo method. This methodology is selected as it provides reliable uncertainty estimations and considers the nonlinearity of the UV processing algorithm. The combined standard uncertainty depends on the Brewer, varying between 2.5 % and 4 % for the 300–350 nm region. For wavelengths below 300 nm, the differences between single- and double-monochromator Brewers increase, due to stray light and dark counts. For example, at 295 nm, the relative uncertainties of single Brewers range between 11–14 % while double Brewers have uncertainties of 4–7 %. These uncertainties arise primarily from radiometric stability, the application of cosine correction, and the irradiance of the lamp used during the instrument calibration. As the intensity of the UV irradiance measured decreases, dark counts, stray light (for single Brewers), and noise become the dominant sources of uncertainty. These results indicate that the overall uncertainty of a Brewer spectroradiometer could be greatly reduced by increasing the frequency of radiometric calibration and improving the traditional entrance optics.

29 April 2025
Verified
Other
Open access
PDF file
CGCarmen González
Carmen González
JVJosé Manuel Vilaplana
José Manuel Vilaplana
ARAlberto Redondas
Alberto Redondas
JLJavier López-Solano
Javier López-Solano
JAJosé María San Atanasio
José María San Atanasio
APAntonio Serrano Pérez
Antonio Serrano Pérez
Brewer spectroradiometers are robust, widely used instruments that have been monitoring global solar ultraviolet (UV) irradiance since the 1990s, playing a key role in solar UV research. Unfortunately, the uncertainties of these measurements are rarely evaluated due to the difficulties involved in the uncertainty propagation. This evaluation is essential to determine the quality of the measurements as well as their comparability to other measurements. In this study, eight double- and two single-monochromator Brewers are characterised and the uncertainty of their global UV measurements is estimated using the Monte Carlo method. This methodology is selected as it provides reliable uncertainty estimations and considers the nonlinearity of the UV processing algorithm. The combined standard uncertainty depends on the Brewer, varying between 2.5 % and 4 % for the 300–350 nm region. For wavelengths below 300 nm, the differences between single- and double-monochromator Brewers increase, due to stray light and dark counts. For example, at 295 nm, the relative uncertainties of single Brewers range between 11–14 % while double Brewers have uncertainties of 4–7 %. These uncertainties arise primarily from radiometric stability, the application of cosine correction, and the irradiance of the lamp used during the instrument calibration. As the intensity of the UV irradiance measured decreases, dark counts, stray light (for single Brewers), and noise become the dominant sources of uncertainty. These results indicate that the overall uncertainty of a Brewer spectroradiometer could be greatly reduced by increasing the frequency of radiometric calibration and improving the traditional entrance optics.