26 December 2023 in Journal of Geophysical Research: Atmospheres
Precise spectral ultraviolet (UV) measurements are needed to ensure human protection as well as to support scientific research. Quantifying the uncertainty of the UV spectra recorded is crucial to evaluate the quality of the measurements which is needed, in turn, for the assessment of their reliability. However, for double‐monochromator spectroradiometers, the analytical derivation of this uncertainty is a challenging task due to the difficulties involved in propagating individual uncertainties. Under these circumstances, a Monte Carlo simulation is a reliable alternative as it does not require the calculation of partial derivatives and considers both nonlinear effects and correlations in the data. In the present study, the uncertainty of the spectral UV irradiance measured by a Brewer MKIII spectrophotometer is evaluated using a Monte Carlo approach. This instrument belongs to the National Institute of Aerospace Technology and has successfully participated in several international campaigns, which ensures its precise calibration. The average expanded uncertainty (k = 2) of the global UV irradiance measured by this instrument varies between 10% at 300 nm and 7% at 363 nm. At shorter wavelengths, it increases sharply due to thermal and electronic noise as well as wavelength misalignment. The results indicate that a Brewer spectrophotometer is suitable for climatological studies and model validation. Nevertheless, a substantial reduction of these uncertainties might be required for accurately detecting long‐term UV trends. Although the study focused on a Brewer spectrometer, the methodology used for the uncertainty analysis is general and can be adapted to most UV spectroradiometers.
15 July 2022 in Atmospheric Measurement Techniques
Spectral measurements of UV irradiance are of great importance for protecting human health as well as for supporting scientific research. To perform these measurements, double monochromator scanning spectroradiometers are the preferred devices thanks to their linearity and stray-light reduction. However, because of their high cost and demanding maintenance, CCD-array-based spectroradiometers are increasingly used for monitoring UV irradiance. Nevertheless, CCD-array spectroradiometers have specific limitations, such as a high detection threshold or stray-light contamination. To overcome these challenges, several manufacturers are striving to develop improved instrumentation. In particular, Gigahertz-Optik GmbH has developed the stray-light-reduced BTS2048-UV-S spectroradiometer series (hereafter “BTS”). In this study, the long-term performance of the BTS and its seasonal behavior, regarding global UV irradiance, was assessed. To carry out the analysis, BTS irradiance measurements were compared against measurements from the Brewer MK-III #150 scanning spectrophotometer during three campaigns. A total of 711 simultaneous spectra, measured under cloud-free conditions and covering a wide range of solar zenith angles (SZAs; from 14 to 70∘) and UV indexes (from 2.4 to 10.6), were used for the comparison. During the three measurement campaigns, the global UV spectral ratio BTS / Brewer was almost constant (at around 0.93) in the 305–360 nm region for SZAs below 70∘. Thus, the BTS calibration was stable during the whole period of study (∼ 1.5 years). Likewise, it showed no significant seasonal or SZA dependence in this wavelength region. Regarding the UV index, a good correlation between the BTS and the Brewer #150 was found, i.e., the dynamic range of the BTS is comparable to that of the Brewer #150. These results confirm the quality of the long-term performance of the BTS array spectroradiometer in measuring global UV irradiance.