1 April 2007 in Solar Energy
1 January 2012 in Energy Procedia
Solar PV systems have evolved from small stand-alone applications through residential and commercial systems to MW-scale installations and groups of systems that feed significant energy into the utility grid. High PV penetration levels create a number of challenges for the management of the operation of the utility grid. This paper will cover the current and historic status of the integration of renewable energies into utility grids over a variety of global regions. This includes grid control and network planning. The technology for the integration of PV is described including the codes and standards governing the utility interactivity requirements. This will include short term dynamic responses as well as power ramp rates. Geographic, technological, and meteorological factors will be discussed. The coordination of meteorology and energy production is a key factor that is examined in detail including real world data. The paper includes a discussion of future utility grid features to support increasing levels of PV and other renewable generation sources
1 October 2016 in Solar Energy
A scheme using satellite-derived irradiance measurements to model the feed-in power of residential photovoltaic (PV) systems in a low voltage distribution grid is described. It is validated against smart meter measurements from a test site with 12 residential PV systems in the city of Ulm, Germany, during May 2013 to December 2014. The PV feed-in power is simulated in a 15-min time resolution based on irradiance data derived from Meteosat Second Generation satellite images by the physically based retrieval scheme Heliosat-4. The PV simulation is based on the nominal power and location of the PV systems as provided by the distribution system operator. Orientation angles are taken from high resolution aerial laser-scan data. The overall average mean error of PV feed-in power is 4.6% and the average root-mean-squared error is 12.3% for the individual systems. Relative values are given with respect to the total installed power of 152.3kWp. Sensitivity studies discuss the need for knowing the exact orientation angles of each individual PV system or the usefulness of a single ground-based measurement as alternative to satellite observations. As an application of the scheme, the modelling of the effect of the power flow from the residential PV on the load flow of the low voltage distribution grid transformer is described and illustrates the advantage of the discussed approach for distribution system operators