Jian Liang

Jian Liang

Auto-generated profile, based on publicly available information

Jian Liang

Department of Civil Engineering

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2018 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
MZMin Zhou
Min Zhou
YSYao Sun
Yao Sun
Zhangjie LiuZhangjie Liu
Zhangjie Liu
XLXing Li
Xing Li
JLJianheng Lin
Jianheng Lin
YLYonglu Liu
Yonglu Liu
A transformer‐less dynamic voltage restorer (DVR) with bipolar voltage gain capability is proposed in this study. The DVR is formed by a three‐leg ac/ac converter with its output capacitor in series with the transmission line. Since the energy used for voltage compensation is obtained from the grid, long‐time voltage disturbances can be compensated without using bulky energy storage elements. As a result, the proposed DVR has the features of compact structure, light weight, and low cost. Moreover, it also has a high reliability as the commutation problem is avoided by adopting the proposed modulation strategy. A detailed analysis of the topology structure and operation principle is given, followed by the developed control method. Finally, simulations and experimental results are presented to verify the validity of the DVR.

1 January 2021 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
JNJiangang Niu
Jiangang Niu
WXWenming Xu
Wenming Xu
JLJingjun Li
Jingjun Li
JLJian Liang
Jian Liang
Fiber‐reinforced polymer (FRP) wrapping has become an attractive strengthening technique for concrete columns. However, the ingress of corrosion into the concrete through the gap of CFRP fiber greatly reduces the durability of concrete and the bearing capacity of specimens. Concrete canvas, a kind of corrosion‐resistant and refractory material, is a promising method to enhance durability and carrying capacity. In this study, the concrete canvas (CC) and carbon fiber‐reinforced polymer (CFRP) were used to jointly reinforce columns with square cross section, octagonal cross section, circular cross section, and elliptical cross section. The influence of section shape on the strengthening effect of the axial compression column was investigated by the axial compression test. The results showed that the section shape had a significant influence on the reinforcement effect of the axial compression column. The carrying load capacity and ductility coefficient of different columns follow this order: square column < oval‐shaped columns < octagonal columns < circle columns. The increased amplitude of bearing capacity for the different columns with the increase of CC layers follows this order: square columns < oval‐shaped columns < circle column < octagonal columns. Compared with the unconstraint columns, the bearing capacity of adopting two‐layer CC columns increased by 129%, 155%, 150%, and 139% for the square, octagonal, circular, and elliptical columns, respectively. The octagonal column has the largest increase range. Compared with the unconstraint columns, the bearing capacity of adopting two‐layer CC columns increased by 348%, 318%, 310%, and 296% for the square, octagonal, elliptical, and circular columns, respectively. The square column has the largest increase range. The stress concentration phenomenon of all section shapes was weakened after the CC was used. The application of the CC on CFRP‐reinforced columns improves column ductility significantly, with some degree of increase in bearing capacity.