Jin Woo

Jin Woo

Auto-generated profile, based on publicly available information

Jin Woo

Post-Carbon Research Centre, RMIT University, 124 La Trobe Street, Melbourne, Victoria 3000, Australia Sustainable Building Innovation Laboratory (SBi Lab), School of Property, Construction and Project Management, RMIT University, 124 La Trobe Street, Melbourne, Victoria 3000, Australia

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2023 in Building and Environment
Verified
Journal Article
Open access
MAMary Myla Andamon
Mary Myla Andamon
PRPriyadarsini Rajagopalan
Priyadarsini Rajagopalan
JWJin Woo
Jin Woo

30 June 2021 in Building Research & Information
Verified
Journal Article
Open access
JWJin Woo
Jin Woo
PRPriyadarsini Rajagopalan
Priyadarsini Rajagopalan
MFMatthew Charles Francis
Matthew Charles Francis
PGPrachi Garnawat
Prachi Garnawat
This paper reports the results of a comprehensive indoor environmental quality (IEQ) evaluation conducted in seven office buildings at an Australian university. A mix of objective and subjective assessments was carried out and a total of 519 staff participated in the survey from various non-academic departments. Three types of buildings were included in this study: ‘Heritage listed’ (c.1880–1890s), ‘Conventional’ (c.1960–1980s) and ‘Modern’ (post 2000) office buildings. Although the measured IEQ conditions were relatively good with no significant fluctuation across the selected buildings, the discrepancy between objective IEQ data and subjective occupant evaluations was noted. The Modern building type designed with fully double-glazed façades showed the highest levels of overall comfort and satisfaction and perceived productivity, whereas the Conventional building type constructed during the late 20th-century period, notable for deep floor plates, had the lowest. The heritage listed type buildings had lower window to wall ratios, yet displayed improved occupant satisfaction across all IEQ areas over the conventional type buildings. The results support that building renovation and regular maintenance can improve occupant comfort and satisfaction within offices. The findings could be useful for property managers looking for strategies to improve the performance of their building stock.

20 October 2021 in Architectural Science Review
Verified
Journal Article
Open access
PRPriyadarsini Rajagopalan
Priyadarsini Rajagopalan
MAMary Myla Andamon
Mary Myla Andamon
JWJin Woo
Jin Woo
Children under 15 years spend over six hours per day in school buildings and are particularly vulnerable to the effects of poor indoor air quality (IAQ). However long-term monitoring of indoor environmental conditions is limited in Australian schools. This study evaluates IAQ in ten Australian school classrooms in the temperate settings of Victoria. Temperature, relative humidity, CO2 concentration, PM2.5 and PM10 were monitored over a period of one year. The temperature and relative humidity values in the monitored classrooms ranged between 18.7°C and 23.8°C and 44–63 RH%, respectively, indicating that the conditions have been mechanically controlled. The average air change (ACH) rates in the 10 school classrooms varied considerably (range: 0.7–4.83 ACH). The ventilation rates ranged from 1.6 Ls−1 to 11.5 Ls−1 per person with 7 out of the 10 classrooms showing ventilation rates below the recommended minimum. This study points to the need for increasing ventilation rates in classrooms.

4 March 2022 in Building and Environment
Verified
Journal Article
Closed access
JWJin Woo
Jin Woo
PRPriyadarsini Rajagopalan
Priyadarsini Rajagopalan
MAMary Myla Andamon
Mary Myla Andamon


19 June 2025 in CIB Conferences
Verified
Journal Article
Open access
PDF file
KKKiranjot Kaur
Kiranjot Kaur
PRPriyadarsini Rajagopalan
Priyadarsini Rajagopalan
JWJin Woo
Jin Woo
HGHarry Garg
Harry Garg
This study explores energy-efficient passive tubular daylighting systems which utilizes natural lighting, reduce energy consumption and improve occupant well-being in buildings. For this, three passive daylighting collectors configuration of flat plate, circular dome and circular Fresnel lens were modelled using AutoCAD and SolidWorks and analysed using ray tracing software TracePro 7.3.4. The light transportation was done using a highly reflective light pipe with a reflectivity of 95%. The collectors were made from Polymethyl methacrylate (PMMA) with refractive index of 1.49 because of highly transmission efficiency, weather resistance, shock resistance, blocks UV, lightweight and cost-effective alternative to glass. The Monte Carlo ray tracing method was employed to assess the optical performance within the photometric range of 380 nm to 720 nm. The results demonstrated that circular Fresnel lens achieved better illuminance and efficiency compared to conventional systems, highlighting their potential for enhancing indoor environmental quality in green buildings.