12 November 2021 in Science Advances
Dark matter interpretations of the DAMA signals are excluded by COSINE-100 with the same NaI(Tl) target for various models.
5 September 2025 in Science Advances
For over 25 years, the DAMA/LIBRA collaboration has claimed to observe an annual modulation signal, suggesting the existence of dark matter interactions. However, no experiment using different target materials has observed a dark matter signal consistent with their result. To address this puzzle, the COSINE-100 collaboration conducted a model-independent test using sodium iodide crystal detectors, the same target material as DAMA/LIBRA. Analyzing data collected over 6.4 years by the effective mass of 61.3 kilograms, with improved energy calibration and time-dependent background modeling, we found no evidence of an annual modulation signal, challenging the DAMA/LIBRA result with a confidence level greater than 3σ. This finding represents a substantial step toward resolving the long-standing debate surrounding DAMA/LIBRA’s dark matter claim, indicating that the observed modulation is unlikely to be caused by dark matter interactions.
1 July 2018 in Journal of Instrumentation
Gas Electron Multipliers have undergone a very consistent development since their invention in 1997. Their production procedures have been tuned in such a way that nowadays it is possible to produce foils with areas of the order of the square meter that can operate at a reasonable gain, uniform over large areas and with a good stability in what concerns electrical discharges. For the 3rd run of LHC, they will be included in the CMS and ALICE experiments after significant upgrades of the detectors, confirming that these structures are suitable for very large experiments. In the special case of Time Projection Chambers, the ion backflow and the energy resolution are sensitive issues that must be addressed and the GEM has shown to be able to deal with both of them. In this work, a stack of three GEMs with different pitches has been studied as a possible future approach for ion backflow suppression to be used in TPCs and other detection concepts. With this approach, an ion backflow of 1 % with an energy resolution of 12 % at 5.9 k\eV has been achieved with the detector operating in an Ar/Co (90/10) mixture at a gain of ~ 2000.
26 June 2023 in Physical Review D
CCCOSINE-100 Collaboration
+50
We present results from a search for solar bosonic dark matter using the annual modulation method with the COSINE-100 experiment. The results were interpreted considering three dark sector bosons models: solar dark photons, Dine-Fischler-Srednicki-Zhitnisky (DFSZ) and Kim-Shifman-Vainshtein-Zakharov (KSVZ) solar axions, and Kaluza-Klein solar axions. No modulation signal compatible with the expected from the models was found from a dataset of 2.82 yr, using 61.3 kg of NaI(Tl) crystals. Therefore, we set a 90% confidence level upper limits for each of the three models studied. For the solar dark photon model, the most stringent mixing parameter upper limit is for dark photons with a mass of 215 eV. For the DFSZ and KSVZ solar axion, and the Kaluza-Klein axion models, the upper limits exclude axion-electron couplings, , above for axion mass below 0.2 keV; and axion-photon couplings, , above for an axion number density of . This is the first experimental search for solar dark photons and DFSZ and KSVZ solar axions using the annual modulation method. The lower background, higher light yield and reduced threshold of NaI(Tl) crystals of the future COSINE-200 experiment are expected to enhance the sensitivity of the analysis shown in this paper. We show the sensitivities for the three models studied, considering the same search method with COSINE-200.
20 April 2026 in Physical Review D
We present results of the search for sub-GeV dark matter interaction with electrons in the NaI(Tl) crystals of the COSINE-100 experiment. The two benchmark scenarios of a heavy and a light vector boson as mediator of the interaction were studied. We found no excess events over the expected background in a dataset of 2.82 years, with a total exposure of 172.9 kg − year . The derived 90% confidence level upper limits exclude a dark matter (DM)-electron scattering cross section above 6.4 × 10 − 33 cm 2 for a DM mass of 0.25 GeV, assuming a light mediator; and above 3.4 × 10 − 37 cm 2 for a 0.4 GeV DM, assuming a heavy mediator, and represent the most stringent constraints for a NaI(Tl) target to date. We also briefly discuss a planned analysis using an annual modulation method below the current 0.7 keV threshold of COSINE-100, down to few photoelectrons yield.
1 March 2026 in Journal of Instrumentation
The COSINE-100U (upgrade) will enhance the sensitivity of the COSINE-100 dark matter search by operating the detector array immersed in liquid scintillator (LS) at -30°C. To validate the detector design for these conditions, we constructed a module using the COSINE-100U encapsulation and performed a dedicated long-term stability study. The module was first monitored at room temperature for ∼110 days in air, followed by a one-week immersion in LAB-based LS to verify initial compatibility. Upon confirming stable optical performance, the temperature was lowered to -33°C. During approximately 150 days of continuous operation at low temperature, we observed no degradation in performance. These results demonstrate the chemical and mechanical robustness of the encapsulation, confirming its suitability for the COSINE-100U physics run.