Gyun Ho Yu

Gyun Ho Yu

Auto-generated profile, based on publicly available information

Gyun Ho Yu

Center for Underground Physics (CUP), Institute for Basic Science (IBS), Daejeon 34126, Republic of Korea

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2021 in Science Advances
Verified
Journal Article
Open access
GAGovinda Adhikari
Govinda Adhikari
ESEstella B. de Souza
Estella B. de Souza
NCNelson Carlin
Nelson Carlin
JCJae Jin Choi
Jae Jin Choi
SCSeonho Choi
Seonho Choi
GYGyun Ho Yu
Gyun Ho Yu
Dark matter interpretations of the DAMA signals are excluded by COSINE-100 with the same NaI(Tl) target for various models.

5 September 2025 in Science Advances
Verified
Journal Article
Open access
NCNelson Carlin
Nelson Carlin
JCJae Young Cho
Jae Young Cho
JCJae Jin Choi
Jae Jin Choi
SCSeonho Choi
Seonho Choi
AEAnthony C. Ezeribe
Anthony C. Ezeribe
GYGyun Ho Yu
Gyun Ho Yu
For over 25 years, the DAMA/LIBRA collaboration has claimed to observe an annual modulation signal, suggesting the existence of dark matter interactions. However, no experiment using different target materials has observed a dark matter signal consistent with their result. To address this puzzle, the COSINE-100 collaboration conducted a model-independent test using sodium iodide crystal detectors, the same target material as DAMA/LIBRA. Analyzing data collected over 6.4 years by the effective mass of 61.3 kilograms, with improved energy calibration and time-dependent background modeling, we found no evidence of an annual modulation signal, challenging the DAMA/LIBRA result with a confidence level greater than 3σ. This finding represents a substantial step toward resolving the long-standing debate surrounding DAMA/LIBRA’s dark matter claim, indicating that the observed modulation is unlikely to be caused by dark matter interactions.

2 December 2025 in Physical Review Letters
Verified
Journal Article
Open access
GYG H Yu
G H Yu
NCN Carlin
N Carlin
JCJ Y Cho
J Y Cho
JCJ J Choi
J J Choi
SCS Choi
S Choi
CCCOSINE-100 Collaboration
COSINE-100 Collaboration
We report limits on weakly interacting massive particle (WIMP) dark matter derived from three years of data collected by the COSINE-100 experiment with NaI(Tl) crystals, achieving an improved energy threshold of 0.7 keV. This lowered threshold enhances sensitivity in the sub-GeV mass range, extending the reach for direct detection of low-mass dark matter. Although no excess of WIMP-like events was observed, the increased sensitivity enabled a model-insensitive comparison between the expected WIMP signal rate—based on mass limits from our data—and DAMA’s reported modulation amplitude. Our findings strongly disfavor the DAMA signal as originating from WIMP interactions, fully excluding DAMA/LIBRA 3 σ allowed regions and providing enhanced WIMP mass limits by an order of magnitude in the spin-independent model compared to previous results. In the spin-dependent model, cross-section upper limits were obtained in the mass range [0.1–5.0] GeV / c 2 , with additional sensitivity to sub-GeV WIMPs through the inclusion of the Migdal effect. These results represent substantial progress in low-mass dark matter exploration and reinforce constraints on the longstanding DAMA claim.

1 March 2026 in Journal of Instrumentation
Verified
Journal Article
Open access
KPK. Park
K. Park
SCS.J. Cho
S.J. Cho
LFL.E. França
L.E. França
CHC. Ha
C. Ha
JKJ. Kim
J. Kim
GYG.H. Yu
G.H. Yu
The COSINE-100U (upgrade) will enhance the sensitivity of the COSINE-100 dark matter search by operating the detector array immersed in liquid scintillator (LS) at -30°C. To validate the detector design for these conditions, we constructed a module using the COSINE-100U encapsulation and performed a dedicated long-term stability study. The module was first monitored at room temperature for ∼110 days in air, followed by a one-week immersion in LAB-based LS to verify initial compatibility. Upon confirming stable optical performance, the temperature was lowered to -33°C. During approximately 150 days of continuous operation at low temperature, we observed no degradation in performance. These results demonstrate the chemical and mechanical robustness of the encapsulation, confirming its suitability for the COSINE-100U physics run.