1 November 2024 in EP Europace
Aims: Catheter ablation (CA) of idiopathic ventricular arrhythmias (VAs) from the epicardial left ventricular summit is challenging. The endocardial approach targets two sites: the endocardial closest site (ECS) to the epicardial earliest activation site (epi-EAS) and the endocardial earliest activation site (endo-EAS). We aimed to differentiate between cases where CA at the ECS was effective and where CA at the endo-EAS yielded success. Methods and results: Fifty-eight patients (47 men; age 60 ± 13 years) were analysed with VAs in which the EAS was observed in the coronary venous system (CVS). Overall, VAs were successfully eliminated in 42 (72%) patients: 8 in the CVS, 8 where the ECS matched with the endo-EAS, 11 at the ECS, and 15 at the endo-EAS. A successful ECS ablation was associated with a shorter epi-EAS–ECS distance (10.2 ± 4.7 vs. 18.8 ± 5.3 mm; P < 0.001) and shorter epi-EAS–left main coronary trunk (LMT) ostial distance (20.3 ± 7.6 vs. 30.3 ± 8.4 mm; P = 0.005), with optimal cut-off values of ≤12.6 and ≤24.0 mm, respectively. A successful endo-EAS ablation was associated with an earlier electrogram at the endo-EAS [23 (8, 36) vs. 15 (0, 19) ms preceding the QRS; P < 0.001] and shorter epi-EAS–endo-EAS interval [6 (1, 8) vs. 22 (12, 25) ms; P < 0.001], with optimal cut-off values of ≥18 and ≤9 ms, respectively. Conclusion: Shorter anatomical distances between the epi-EAS and ECS, and between the epi-EAS and LMT ostium, predict a successful ECS ablation. The prematurity of the endo-EAS electrogram and a shorter interval between the epi-EAS and endo-EAS predicted a successful endo-EAS ablation.
5 April 2024 in Journal of Arrhythmia
Background: Periesophageal vagal nerve injury (PNI) is an unpredictable and serious complication of atrial fibrillation (AF) ablation. We aimed to identify the factors associated with symptomatic PNI.Methods: This study included 1391 patients who underwent ablation index‐guided pulmonary vein isolation (PVI) using the CARTO system. The target ablation index was set at 550, except for the left atrial (LA) posterior wall near the esophagus, where radiofrequency (RF) power and duration were limited. Ten patients (0.72%) were diagnosed with symptomatic PNI. We randomly selected 40 patients without PNI (1:4 ratio) matched based on age, sex, body mass index, LA diameter, type of AF, and esophageal location. We measured the shortest distance from the RF lesions to the esophagus (LED) and classified the RF lesions according to the LED into four groups: 0–5, 5–10, 10–15, and 15–20 mm. We conducted a comparative analysis of classified RF lesions between patients with PNI (n = 10) and those without (n = 40).Results: The contact force at LED 0–5 mm was significantly higher in patients with PNI than in those without (14.6 ± 1.7 vs. 12.0 ± 2.9 g; p = .01). Multivariate logistic analysis revealed that the independent factor for PNI was contact force at an LED of 0–5 mm (odds ratio: 1.506; 95% confidence interval: 1.053–2.153; p = .025).Conclusions: The symptomatic PNI was significantly associated with a higher contact force near the esophagus. Strategies for regulating contact force near the esophagus may aid in the prevention of PNI.
9 March 2021 in Heart and Vessels
9 September 2025 in Heart Rhythm O2
Pulsed field ablation (PFA) for atrial fibrillation can induce hemolysis, particularly when pulsed field (PF) energy is delivered from catheter electrodes that are not in contact with myocardial tissue. The variable-loop circular catheter (VLCC) incorporates tissue proximity indication (TPI) software to identify catheter-tissue contact. Whether PFA applications delivered from TPI-negative (noncontact) VLCC electrodes contribute to hemolysis remains unclear. The purpose of this study was to determine whether PFA delivered from TPI-negative VLCC electrodes is associated with postprocedural hemolysis. We retrospectively analyzed 20 consecutive patients who underwent their first PFA using the VLCC and CARTO 3 system (Biosense Webster Inc.). For each 3-pulse application set, catheter-tissue contact was assessed using TPI. We counted the cumulative number of VLCC electrode uses delivering PF energy; among these, those that were TPI-negative were summed and defined as the cumulative number of TPI-negative electrode uses (nTPI-EU). Postoperative lactate dehydrogenase (LDH), total bilirubin (T-Bil), and the postoperative-to-preoperative haptoglobin ratio served as hemolysis markers. A mean of 78.3 ± 20.0 PFA applications (772.9 ± 204.1 VLCC electrode uses) were delivered per patient; the mean nTPI-EU was 438.8 ± 238.1. Compared with preoperative values, postoperative LDH and T-Bil increased significantly whereas haptoglobin decreased (P < .01 for all). nTPI-EU correlated positively with LDH (r = 0.663; P < .01) and T-Bil (r = 0.736; P < .01) and negatively with the postoperative-to-preoperative haptoglobin ratio (r = −0.556; P = .01). The cumulative number of noncontact catheter electrodes delivering PF energy was associated with hemolysis. Strategies that minimize the number of noncontact catheter electrodes, in addition to limiting total PFA applications, may reduce the risk of hemolysis.
5 February 2025 in JACC: Clinical Electrophysiology
16 September 2023 in Journal of Arrhythmia
We present an atypical response to single atrial premature depolarization (APD) in a long RP’ tachycardia. APD advanced the His‐bundle potential immediately after it and resulted in a VA block; however, tachycardia persisted and consequently exhibited an A‐V‐V‐A response. We propose the mechanism for an A‐V‐V‐A response to APD in a long RP' tachycardia.