21 March 2025 in IEEE Transactions on Medical Imaging
Score-based diffusion models are new and powerful tools for image generation. They are based on a forward stochastic process where an image is degraded with additive white noise and optional input scaling. A neural network can be trained to estimate the time-dependent score function, and used to run the reverse-time stochastic process to generate new samples from the training image distribution. However, one issue is that sampling the reverse process requires many passes of the neural network. In this work we present Fourier Diffusion Models which replace the scalar operations of the forward process with linear shift invariant systems and additive spatially-stationary noise. This allows for a model of continuous probability flow from true images to measurements with a specific modulation transfer function (MTF) and noise power spectrum (NPS). We also derive the reverse process for posterior sampling of high-quality images given blurry noisy measurements. We conducted a computational experiment using the Lung Image Database Consortium dataset of chest CT images and simulated CT measurements with correlated noise and system blur. Our results show that Fourier diffusion models can improve image quality for supervised diffusion posterior sampling relative to existing conditional diffusion models.
4 April 2022 in IEEE Transactions on Medical Imaging
Spectral CT has shown promise for high-sensitivity quantitative imaging and material decomposition. This work presents a new device called a spatial-spectral filter (SSF) which consists of a tiled array of filter materials positioned near the x-ray source that is used to modulate the spectral shape of the x-ray beam. The filter is moved to obtain projection data that is sparse in each spectral channel. To process this sparse data, we employ a one-step direct model-based material decomposition (MBMD) to reconstruct basis material density images directly from the SSF CT data. To evaluate different possible SSF designs, we define a new Fisher-information-based predictive image quality metric called separability index which characterizes the ability of a spectral CT system to distinguish between the signals from two or more materials. This spectral CT performance metric can be used to optimize spectral CT system design. We conducted simulation-based design optimization study to find optimized combinations of filter materials, filter thicknesses, filter widths, and source settings. Finally, we present MBMD results using simulated SSF CT measurements from the optimized designs to demonstrate the ability to reconstruct basis material density images and to show the benefits of the optimized designs. Our results indicate that optimizing SSF CT for separability leads to high-performance at material discrimination tasks.
30 November 2023 in IEEE Transactions on Medical Imaging
Score-based diffusion models are new and powerful tools for image generation. They are based on a forward stochastic process where an image is degraded with additive white noise and optional input scaling. A neural network can be trained to estimate the time-dependent score function, and used to run the reverse-time stochastic process to generate new samples from the training image distribution. However, one issue is that sampling the reverse process requires many passes of the neural network. In this work we present Fourier Diffusion Models which replace the scalar operations of the forward process with linear shift invariant systems and additive spatially-stationary noise. This allows for a model of continuous probability flow from true images to measurements with a specific modulation transfer function (MTF) and noise power spectrum (NPS). We also derive the reverse process for posterior sampling of high-quality images given blurry noisy measurements. We conducted a computational experiment using the Lung Image Database Consortium dataset of chest CT images and simulated low-dose CT measurements with noise and system blur. Our results show that Fourier diffusion models can improve image quality for supervised diffusion posterior sampling relative to existing conditional diffusion models.
16 May 2025 in IEEE Transactions on Biomedical Engineering
Objective: Digital subtraction angiography (DSA) is the gold standard modality for diagnostics and guidance for interventional procedures. Spectral imaging has previously been explored for DSA, but severe noise amplification from material decomposition has impeded clinical adoption. We present a novel joint processing strategy that leverages both temporal and spectral information for material decomposition to address this issue. Methods: We develop a model-based material decomposition approach that utilizes the pre- and post-contrast images simultaneously for material estimation. Performance was evaluated on a small-vessel phantom on a test bench with a photon-counting detector. Joint processing was compared with temporal subtraction and previously proposed spectral DSA techniques including hybrid subtraction and conventional three-material decomposition. Additional simulation was performed to investigate performance with perfectly calibrated spectral response and sensitivity to patient motion. Results: The improved conditioning of the proposed method effectively reduces bias and noise in the spectral results and allows three-material decomposition with dual-energy spectral measurements. The method achieved more than an order of magnitude variance reduction compared to previously proposed spectral DSA techniques. Compared to temporal subtraction, a mean variance reduction of 23.9% was achieved in simulation and 10.8% in experimental data. The degree of reduction is object-dependent. Noise reduction achieved in physical experiments is slightly lower than that in simulation, likely due to bias from imperfect spectral calibration. The method is equally sensitive to motion compared to temporal subtraction. Conclusion: The proposed method addresses a major image quality challenge limiting previous approaches and outperforms temporal subtraction. Significance: Such improvements facilitate the clinical translation of spectral angiography.