Grace Jianan Gang

Grace Jianan Gang

Auto-generated profile, based on publicly available information

Grace Jianan Gang

Department of Radiology, University of Pennsylvania, Philadelphia, PA, U.S.A.

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2019 in Journal of Medical Imaging
Verified
Journal Article
Open access
PDF file
JSJ. Webster Stayman
J. Webster Stayman
SCSarah Capostagno
Sarah Capostagno
GGGrace J. Gang
Grace J. Gang
JSJeffrey H. Siewerdsen
Jeffrey H. Siewerdsen
Cone-beam computed tomography (CBCT) finds application in many clinical interventions to provide up-to-date imaging (often in conjunction with hardware/instrumentation) for improved localization and assessment of treatment delivery.1 – 5 Intraoperative CBCT imaging platforms are often based on C-arm devices with flat-panel detectors that are capable of radiography and fluoroscopy in addition to the three-dimensional (3-D) CBCT. Advanced versions of these systems are motorized on several axes to permit nonisocentric source–detector orbits, to expand the field of view (FOV) in 3-D image reconstructions, and to quickly reposition between specific radiographic/fluoroscopic views. Such systems include floor- and ceiling-mounted C-arms as well as robotic C-arms6 with many degrees of motion freedom. In addition to C-arm systems, some CBCT mammography7 and body imaging systems8 are also capable of complex source–detector trajectories.

1 July 2024 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
SLShudong Li
Shudong Li
XJXiao Jiang
Xiao Jiang
MTMatthew Tivnan
Matthew Tivnan
GGGrace J. Gang
Grace J. Gang
YSYuan Shen
Yuan Shen
JSJ. Webster Stayman
J. Webster Stayman
PurposeRecently, diffusion posterior sampling (DPS), where score-based diffusion priors are combined with likelihood models, has been used to produce high-quality computed tomography (CT) images given low-quality measurements. This technique permits one-time, unsupervised training of a CT prior, which can then be incorporated with an arbitrary data model. However, current methods rely on a linear model of X-ray CT physics to reconstruct. Although it is common to linearize the transmission tomography reconstruction problem, this is an approximation to the true and inherently nonlinear forward model. We propose a DPS method that integrates a general nonlinear measurement model.ApproachWe implement a traditional unconditional diffusion model by training a prior score function estimator and apply Bayes’ rule to combine this prior with a measurement likelihood score function derived from the nonlinear physical model to arrive at a posterior score function that can be used to sample the reverse-time diffusion process. We develop computational enhancements for the approach and evaluate the reconstruction approach in several simulation studies.ResultsThe proposed nonlinear DPS provides improved performance over traditional reconstruction methods and DPS with a linear model. Moreover, as compared with a conditionally trained deep learning approach, the nonlinear DPS approach shows a better ability to provide high-quality images for different acquisition protocols.ConclusionThis plug-and-play method allows the incorporation of a diffusion-based prior with a general nonlinear CT measurement model. This permits the application of the approach to different systems, protocols, etc., without the need for any additional training.

6 April 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
GGGrace Jianan Gang
Grace Jianan Gang
RDRadhika Deshpande
Radhika Deshpande
JSJoseph Webster Stayman
Joseph Webster Stayman
Radiomics have been extensively investigated as quantitative biomarkers that can enhance the utility of imaging studies and aid the clinical decision making process. A major challenge to the clinical translation of radiomics is their variability as a result of different imaging and reconstruction protocols. In this work, we present a novel radiomics standardization framework capable of modeling and recovering the underlying radiomic feature in images that have been corrupted by the effects of spatial resolution and noise. We focus on two classes of radiomics based on pixel value distributions—i.e. histograms and gray-level co-occurrence matrices (GLCMs). We developed a model that predicts these distributions in the presence of system blur and noise, and used that model to invert these physical effects and recover the underlying distributions. Specifically, the effect of blur on histogram and GLCM is highly image-dependent, while additive noise convolves the histogram/GLCM of the noiseless image with those of the noise. The recovery method therefore consists of two deconvolution operations: the first in the image domain to remove the effect of system blur, the second in the histogram/GLCM domain to remove the effect of noise. The performance of the proposed recovery strategy was investigated using a set of texture phantoms and an emulated computed tomography imaging chain with a range of realistic blur and noise levels. The proposed method was able to obtain histogram and GLCM estimates that closely resemble the ground truth. The method performed well across imaging conditions and significantly lowered the variability associated with different imaging protocols. This improvement also translated to better classification accuracy, where recovered radiomic values result in greater separation of radiomic clusters for two different texture phantoms as compared to values derived from the original blurred and noisy images. In summary, the novel radiomics standardization framework demonstrates high potential for mitigating radiomic variability as a result of the imaging system and can potentially be integrated as a preprocessing step towards more robust and reproducible radiomic models.

21 June 2019 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
RMRuben De Man
Ruben De Man
GGGrace J. Gang
Grace J. Gang
XLXin Li
Xin Li
Ge WangGe Wang
Ge Wang
Detection and characterization of abnormalities in clinical imaging are of utmost importance for patient diagnosis and treatment. We present a comparison of convolutional neural network (CNN) and human observer performance on a simulated lesion detection and characterization task. We apply both conventional performance metrics, including accuracy and nonconventional metrics such as lift charts to perform qualitative and quantitative comparisons of each type of observer. It is determined that the CNN generally outperforms the human observers, particularly at high noise levels. However, high noise correlation reduces the relative performance of the CNN, and human observer performance is comparable to CNN under these conditions. These findings extend into the field of diagnostic radiology, where the adoption of deep learning is starting to become widespread. Consideration of the applications for which deep learning is most effective is of critical importance to this development.

13 June 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
HZHao Zhang
Hao Zhang
GGGrace J. Gang
Grace J. Gang
HDHao Dang
Hao Dang
JSJ. Webster Stayman
J. Webster Stayman
Prior-image-based reconstruction (PIBR) methods have demonstrated great potential for radiation dose reduction in computed tomography applications. PIBR methods take advantage of shared anatomical information between sequential scans by incorporating a patient-specific prior image into the reconstruction objective function, often as a form of regularization. However, one major challenge with PIBR methods is how to optimally determine the prior image regularization strength which balances anatomical information from the prior image with data fitting to the current measurements. Too little prior information yields limited improvements over traditional model-based iterative reconstruction, while too much prior information can force anatomical features from the prior image not supported by the measurement data, concealing true anatomical changes. In this paper, we develop quantitative measures of the bias associated with PIBR. This bias exhibits as a fractional reconstructed contrast of the difference between the prior image and current anatomy, which is quite different from traditional reconstruction biases that are typically quantified in terms of spatial resolution or artifacts. We have derived an analytical relationship between the PIBR bias and prior image regularization strength and illustrated how this relationship can be used as a predictive tool to prospectively determine prior image regularization strength to admit specific kinds of anatomical change in the reconstruction. Because bias is dependent on local statistics, we further generalized shift-variant prior image penalties that permit uniform (shift invariant) admission of anatomical changes across the imaging field of view. We validated the mathematical framework in phantom studies and compared bias predictions with estimates based on brute force exhaustive evaluation using numerous iterative reconstructions across regularization values. The experimental results demonstrate that the proposed analytical approach can predict the bias-regularization relationship accurately, allowing for prospective determination of the prior image regularization strength in PIBR. Thus, the proposed approach provides an important tool for controlling image quality of PIBR methods in a reliable, robust, and efficient fashion.

21 March 2025 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
MTMatthew Tivnan
Matthew Tivnan
JTJacopo Teneggi
Jacopo Teneggi
TLTzu-Cheng Lee
Tzu-Cheng Lee
RZRuoqiao Zhang
Ruoqiao Zhang
KBKirsten Boedeker
Kirsten Boedeker
JSJ. Webster Stayman
J. Webster Stayman
Score-based diffusion models are new and powerful tools for image generation. They are based on a forward stochastic process where an image is degraded with additive white noise and optional input scaling. A neural network can be trained to estimate the time-dependent score function, and used to run the reverse-time stochastic process to generate new samples from the training image distribution. However, one issue is that sampling the reverse process requires many passes of the neural network. In this work we present Fourier Diffusion Models which replace the scalar operations of the forward process with linear shift invariant systems and additive spatially-stationary noise. This allows for a model of continuous probability flow from true images to measurements with a specific modulation transfer function (MTF) and noise power spectrum (NPS). We also derive the reverse process for posterior sampling of high-quality images given blurry noisy measurements. We conducted a computational experiment using the Lung Image Database Consortium dataset of chest CT images and simulated CT measurements with correlated noise and system blur. Our results show that Fourier diffusion models can improve image quality for supervised diffusion posterior sampling relative to existing conditional diffusion models.