Adwait Deshpande

Adwait Deshpande

Auto-generated profile, based on publicly available information

Adwait Deshpande

Department of Electrical and Computer Engineering, The University of Utah, Salt Lake City, UT, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
CGChayanjit Ghosh
Chayanjit Ghosh
AMAlex Mastrangelo
Alex Mastrangelo
MKMohit Karkhanis
Mohit Karkhanis
ADAdwait Deshpande
Adwait Deshpande
ABAishwaryadev Banerjee
Aishwaryadev Banerjee
CMCarlos H. Mastrangelo
Carlos H. Mastrangelo
Objective: In this paper, we present a novel, low-profile, scleral-coil based, distance ranging system which is suitable for smart, accommodating contact lenses. Methods: We measure the induced emf between a set of four thin semi-circular coils patterned on flexible Kapton substrates that conform to the eyes’ sclera. This induced emf is a function of eye gaze angles. The system then determines the distance from the eyes to the desired object via the triangulation of these eye gaze angles Results : Experiments on eyeball simulated tissue gels indicate an accurate prediction of object distance in the 0.1-15 D range with a 0.15 D RMS error and object direction in the −15 to 15-degree arc with 0.4-degree RMS error, respectively. The energy required was determined to be as low as 20 μJ per range reading. Conclusion: Experimental data shows that our proposed new method of eye-tracking and distance ranging system can accurately predict eye-gaze angles and object-distance, whilst using only 20 μJ per range reading. Significance: The high-accuracy, low-profile and reduced energy requirements of the proposed eye-tracking technique, make it suitable for applications in the vast field of adaptive optics such as smart contact lenses and other low-power vision corrective applications.

10 July 2022
Verified
Conference Paper
Closed access
ADAdwait Deshpande
Adwait Deshpande
CGChayanjit Ghosh
Chayanjit Ghosh
EPErfan Pourshaban
Erfan Pourshaban
MKMohit U. Karkhanis
Mohit U. Karkhanis
ABAishwaryadev Banerjee
Aishwaryadev Banerjee
CMCarlos Mastrangelo
Carlos Mastrangelo
One of the essential requirements of any flexible substrate electronic system is the availability of reliable, high density, fine pitch interconnects between components. In this work, we demonstrate a high-toughness two-layer (aluminum, N-doped polysilicon) composite wiring scheme. The top aluminum layer carries most of the current while the polysilicon underlayer electrically bridges any cracks present on the top aluminum induced by flexing thus maintaining electrical conductivity even at very high stresses. When composite and Al control wires on a flexible tape were subject to 4000 cycles of bending, we observed that Al control wires fracture at a 2.5 mm radius of curvature but the composite wires maintain electrical conduction with an increased resistance.

19 July 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MHMd. Rabiul Hasan
Md. Rabiul Hasan
ANAMIRALI NIKEGHBAL
AMIRALI NIKEGHBAL
STSteven Tran
Steven Tran
ADAdwait Deshpande
Adwait Deshpande
MKMohit U. Karkhanis
Mohit U. Karkhanis
CMCarlos Mastrangelo
Carlos Mastrangelo
We present a novel mid-infrared spectrometer that operates within the spectral range of 3-5 μm range for atmospheric gas measurements without the assistance of a vacuum. This spectrometer utilizes an array of silicon microbolometers, each with a different overlapping broad spectral response. Each microbolometer features a suspended silicon nitride platform, a polysilicon thermistor, and an infrared absorber layer all positioned above platinum mirror. By utilizing this membrane-based microbolometer, the device achieved a 10-fold increase in response when compared to regular substrate-based microbolometer at an average of 45,000 V/W responsivity, allowing for a heightened detectivity of 2.49 x 10 8 cm√Hz/W. The spectrum of the incoming radiation is obtained computationally from the bolometer array collective response via regularization methods, thus eliminating the need for costly narrowband IR filters. Additionally, the device’s gas detection capability was validated with CO 2 and CO gas testing, both of which exhibit significant absorption within the expected 3-5 μm mid-infrared region.

17 March 2023 in IEEE Access
Verified
Journal Article
Open access
ADAdwait Deshpande
Adwait Deshpande
MKMohit U. Karkhanis
Mohit U. Karkhanis
CGChayanjit Ghosh
Chayanjit Ghosh
EPErfan Pourshaban
Erfan Pourshaban
MHMd. Rabiul Hasan
Md. Rabiul Hasan
CMCarlos Mastrangelo
Carlos Mastrangelo
We demonstrate the realization of a very low energy, on-the-eye vergence-type distance ranger based on sensing of a locally-uniform vector field, specifically the earth’s magnetic field. This ranging method is passive, only requiring measurement of the magnetic field vector at both eyeballs utilizing magnetometer chips placed on the eye scleral regions. The eye vergence angle and range distance are calculated from these two vector quantities. The method can obtain a range reading with as little as 118 nJ of energy consumed per eye for 3.3V and 50 nJ when operated at 1.9V. This method is thus suitable for applications where energy storage is very limited such as in smart contacts vision correcting microsystems.

3 March 2026 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
ANAMIRALI NIKEGHBAL
AMIRALI NIKEGHBAL
MHMd. Rabiul Hasan
Md. Rabiul Hasan
FSFarhan Sadik Sium
Farhan Sadik Sium
FMFatemeh Momeni
Fatemeh Momeni
ADAdwait Deshpande
Adwait Deshpande
CMCarlos Mastrangelo
Carlos Mastrangelo
We present a new palladium-based nanogap hydrogen sensor designed for fast, low-concentration H2 detection in environmental monitoring applications. The device consists of a long electrically-conductive low-stress palladium cantilever beam separated by a nanometer-sized air gap from a second cantilever beam of different length placed near the first beam tip thus forming a H2-dependent capacitor. The cantilevers are anchored on top of a thermally-isolated SiN membrane with an integrated microheater that maintains the sensor at constant temperature. When exposed to H2, the capacitor nanogap is reduced resulting in a change in capacitance with H2 sensitivity $S_{\mathrm {H2}} =0.15$ fF/ppm. The sensor shows a consistent response up to $55~^{\circ }$ C with a thermal drift smaller than 0.22 aF/oC and a minimum detectable signal of 10 ppm. The device repeatability was confirmed across 5 consecutive test cycles. Selectivity tests show negligible response to common interfering gases CO, CO2, CH4, water vapor and NH3 ( $S_{i}\lt 5.2\times 1{0}^{-6}$ fF/ppm). The sensor exhibited a response time of approximately 390 ms upon exposure to H2.[2025-0141]

6 October 2026 in Biomedical Optics Express
Verified
Journal Article
Closed access
SASunday Oluwafemi Ajibade
Sunday Oluwafemi Ajibade
ANAmirali Nikeghbal
Amirali Nikeghbal
MHMd Rabiul Hasan
Md Rabiul Hasan
ADAdwait Deshpande
Adwait Deshpande
HKHanseup Kim
Hanseup Kim
CMCarlos H. Mastrangelo
Carlos H. Mastrangelo
Smart contact lenses require low-power inter-eye communication to support binocular sensing without a shared electrical ground. This paper presents a ground-isolated galvanic body-coupled telemetry link between independently powered ocular platforms. A reciprocal two-port channel model predicted approximately 50 dB inter-eye attenuation, validated through human-head and ex vivo pig-eye transfer-function measurements. Communication experiments with off-the-shelf chips achieved packet success rates of up to 99.61% through biological tissue. Energy analysis showed that the straight-serial transmitter consumed approximately 208 μJ/message (5.5 μJ/bit) at 9.6 kb/s, while the biphasic signaling scheme reduced the transmitter energy to 14.9 μJ/message (0.391 μJ/bit). These results demonstrate the feasibility of low-power galvanic body-coupled inter-eye communication for future smart contact lens systems supporting binocular sensing, differential magnetometry, and ocular telemetry.