7 July 2021 in IEEE Transactions on Biomedical Engineering
Objective: Presbyopia, an age-related ocular disorder, is characterized by the loss in the accommodative abilities of the human eye. Conventional methods of correcting presbyopia divide the field of view, thereby resulting in significant vision impairment. We demonstrate the design, assembly and evaluation of autofocusing eyeglasses for restoration of accommodation without dividing the field of view. Methods: The adaptive optics eyeglasses comprise of two variable-focus liquid lenses, a time-of-flight range sensor and low-power, dual microprocessor control electronics, housed within an ergonomic frame. Subject-specific accommodation deficiency models were utilized to demonstrate high-fidelity accommodative correction. The abilities of this system to reduce accommodation deficiency, its power consumption, response time, optical performance and MTF were evaluated. Results: Average corrected accommodation deficiencies for 5 subjects ranged from -0.021 D to 0.016 D. Each accommodation correction calculation was performed in ∼67 ms which consumed 4.86 mJ of energy. The optical resolution of the system was 10.5 cycles/degree, and featured a restorative accommodative range of 4.3 D. This system was capable of running for up to 19 hours between charge cycles and weighed ∼132 g. Conclusion: The design, assembly and performance of an autofocusing eyeglasses system to restore accommodation in presbyopes has been demonstrated. Significance: The new autofocusing eyeglasses system presented in this article has the potential to restore pre-presbyopic levels of accommodation in subjects diagnosed with presbyopia.
5 May 2023 in Optics Express
We demonstrate the implementation of a low-power, low-profile, varifocal liquid-crystal Fresnel lens stack suitable for tunable imaging in smart contact lenses. The lens stack consists of a high-order refractive-type liquid crystal Fresnel chamber, a voltage-controlled twisted nematic cell, a linear polarizer and a fixed offset lens. The lens stack has an aperture of 4 mm and thickness is ∼980 µm. The varifocal lens requires ∼2.5 VRMS for a maximum optical power change of ∼6.5 D consuming electrical power of ∼2.6 µW. The maximum RMS wavefront aberration error was 0.2 µm and the chromatic aberration was 0.008 D/nm. The average BRISQUE image quality score of the Fresnel lens was 35.23 compared to 57.23 for a curved LC lens of comparable power indicating a superior Fresnel imaging quality.
24 November 2020 in IEEE Transactions on Biomedical Engineering
Objective: In this paper, we present a novel, low-profile, scleral-coil based, distance ranging system which is suitable for smart, accommodating contact lenses. Methods: We measure the induced emf between a set of four thin semi-circular coils patterned on flexible Kapton substrates that conform to the eyes’ sclera. This induced emf is a function of eye gaze angles. The system then determines the distance from the eyes to the desired object via the triangulation of these eye gaze angles Results : Experiments on eyeball simulated tissue gels indicate an accurate prediction of object distance in the 0.1-15 D range with a 0.15 D RMS error and object direction in the −15 to 15-degree arc with 0.4-degree RMS error, respectively. The energy required was determined to be as low as 20 μJ per range reading. Conclusion: Experimental data shows that our proposed new method of eye-tracking and distance ranging system can accurately predict eye-gaze angles and object-distance, whilst using only 20 μJ per range reading. Significance: The high-accuracy, low-profile and reduced energy requirements of the proposed eye-tracking technique, make it suitable for applications in the vast field of adaptive optics such as smart contact lenses and other low-power vision corrective applications.
29 June 2022 in IEEE Access
Subjective accommodation refractive error models are essential for implementing adaptive vision correction devices that utilize varifocal optics. This article describes compact empirical models of subjective accommodative refractive errors in subjects with advanced presbyopia. The models are based on measurements of subjective refractive errors from fifteen presbyopes over the age of 45 using commercially available focus-tunable eyeglasses under three different illumination conditions over a 3.08D accommodation stimulus range. The resulting average residual root-mean-squared (RMS) error values for the best fitting 8-parameter model was 0.25D compared to an average RMS error of 0.4D for the conventional DDF and HHG models. The RMS error for the best-fitting model is below the average refractive error of the human eye.