Sergey V. Kagramanov

Sergey V. Kagramanov

Auto-generated profile, based on publicly available information

Sergey V. Kagramanov

Priorov National Medical Research Center of Traumatology and Orthopedics

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2023 in N.N. Priorov Journal of Traumatology and Orthopedics
Verified
Journal Article
Open access
PDF file
HAHovakim A. Aleksanyan
Hovakim A. Aleksanyan
HCHamlet A. Chragyan
Hamlet A. Chragyan
SKSergey V. Kagramanov
Sergey V. Kagramanov
AIArtem V. Ivanov
Artem V. Ivanov
KUKonstantin Yu. Ukolov
Konstantin Yu. Ukolov
ЧАЧрагян Гамлет Ашотович
Чрагян Гамлет Ашотович
BACKGROUND: 3D-printed implants are one of the options for acetabulum reconstruction. The popularity of this technique is increasing every year. AIM: To evaluate the early clinical, radiological and functional results of revision arthroplasty using individual acetabular components in patients with acetabulum bone defects. MATERIALS AND METHODS: Revision endoprosthetics was performed in 50 patients. There were 36 female and 14 male patients. The patients mean age was 60.413.4 (2389) years. According to the Paprosky classification, the defects in 1 case corresponded to type IIC, in 12 cases to type IIIA, in 37 cases to type IIIB, including 8 cases with violation of the acetabulum integrity. Hip joint function was assessed using the Harris Hip Score (HHS), pain severity using the Visual Analogue Scale (VAS), and social adjustment using the Western Ontario and McMaster Universities Arthritis Index (WOMAC). RESULTS: Significant improvement was obtained on all assessment scales. The HHS score improved on average from 33.6 to 87.1 points, the VAS scale from 78.1 to 4.7 points, and the WOMAC from 75.8 to 11.6 points. There were 8 cases (21%) with complications in total. In one case with a violation of the acetabulum integrity we observed migration of the sciatic bone from the lower flange of the construct. CONCLUSION: Thus, the results of the acetabulum reconstruction using individually fabricated acetabular components are promising.

31 March 2025 in Nauka Molodykh (Eruditio Juvenium)
Verified
Journal Article
Closed access
NPNational Medical Research Center of Traumatology and Orthopedics named after N. N. Priorov
National Medical Research Center of Traumatology and Orthopedics named after N. N. Priorov
IGIsrail M.–Kh. Gayrabekov
Israil M.–Kh. Gayrabekov
SKSergey V. Kagramanov
Sergey V. Kagramanov
HAHovakim A. Aleksanyan
Hovakim A. Aleksanyan
NZNikolay Zagorodniy
Nikolay Zagorodniy
MKMukhamed R. Khazhkasimov
Mukhamed R. Khazhkasimov
INTRODUCTION: In recent years, robot-assisted total knee replacement is gaining increasing significance due to its potential in improving clinical outcomes and reducing the risk of complications. The introduction of robotic systems (RSs) in surgical practice permitted to improve the accuracy of implant placement, which is of key significance for restoring the normal joint function. AIM: To analyze the use of modern RSs in the knee arthroplasty (KA) based of the available literature sources. MATERIALS AND METHODS: In the course of study, a search was conducted in the MEDLINE, CyberLeninka, Mendeley, Web of Science and EMBASE databases for clinical studies, review articles and meta-analyses that addressed the topic of total knee arthroplasty in humans using both conventional and robot-assisted methods. RSs provide support to surgeons in bone cutting and ensure continuous feedback during surgery permitting to achieve the optimal kinematics of the joint and soft tissue balance. Accurate information about position and movement of instruments minimizes the risk of implant malposition, which is a common cause of reoperations. Different RSs, such as Cuvis Joint™ and МАКО among others, offer unique advantages and functionalities, each having particular applications and limitations. CONCLUSION: The introduction of robot-assisted technologies in knee arthroplasty represents a significant progress in orthopedic surgery. Further research and accumulation of the clinical experience will help optimize application of these systems, which will probably lead to improvement of long-term treatment outcomes.

9 September 2023 in N.N. Priorov Journal of Traumatology and Orthopedics
Verified
Journal Article
Open access
PDF file
HAHovakim A. Aleksanyan
Hovakim A. Aleksanyan
HCHamlet A. Chragyan
Hamlet A. Chragyan
SKSergey V. Kagramanov
Sergey V. Kagramanov
RKRuslan A. Khanmuradov
Ruslan A. Khanmuradov
NZNikolay Zagorodniy
Nikolay Zagorodniy
ЧАЧрагян Гамлет Ашотович
Чрагян Гамлет Ашотович
BACKGROUND: The incidence of total hip replacements is increasing every year. Acetabular defects are becoming more frequent, with Paprosky type IIIA and above becoming more common. Recently, customized 3D-printed constructs have been used to remodel severe defects. We wanted to demonstrate the possibility of treating a patient with a severe acetabular defect by performing a one-stage revision endoprosthesis using a customized design. CLINICAL CASES DESCRIPTION: A 69-year-old patient underwent primary total hip replacement of the right hip joint with a Biomet endoprosthesis for coxarthrosis in 2010. In 2011 on the left side with a Zimmer endoprosthesis. In 2013 revision endoprosthesis of the right hip joint due to instability was preformed. In the postoperative period, there were repeated dislocations with subsequent closed repositioning. In 2015, revision endoprosthetic replacement with a Burkh-Schneider antiprotrusion ring was done for recurrent dislocation. In november 2017, she was diagnosed with instability of the right total hip joint, for which she underwent revision hip replacement with a customized acetabular component. HHS score before revision arthroplasty was 18 points, 1 month after surgery 75 points, after 3 months 65, after 6 months 82, after 4 years 74. Quality of life was assessed using the WOMAC scale: 92 points before surgery, 38 points 1 month after surgery, 31 points in 3 months, 15 points in 6 months, and 35 points in 4 years. As of the last visit, the patient moves with a cane, and still has a limp due to scar remodeling and gluteal muscles atrophy. CONCLUSION: In case of severe acetabular defects, the use of individual components allows achieving reliable "implantbone" fixation, which leads to improved functional results. However, in chronic pelvic bone integrity defects, the use of an individual acetabular component does not always achieve reliable stabilization. All existing methods for solving this problem are currently ambiguous and require further improvement.

12 September 2026 in Russian surgical journal
Verified
Journal Article
Open access
PDF file
NZNikolay Zagorodniy
Nikolay Zagorodniy
ANA. G. Nazarenko
A. G. Nazarenko
SKS. V. Kagramanov
S. V. Kagramanov
OAO. A. Aleksanyan
O. A. Aleksanyan
GCG. A. Chragyan
G. A. Chragyan
МАМ. Р. Абдуллин
М. Р. Абдуллин
The objective of this study was to demonstrate, using a clinical example, the possibility of one-stage revision hip arthroplasty with a custom 3D-printed acetabular implant for an extensive acetabular defect with pelvic discontinuity, and to review recent literature on this topic. We report a 45-year-old female patient with multiple prior hip surgeries (reconstructive procedures in childhood; primary and revision arthroplasties in 1991, 1998, 2001 and 2012) who presented in 2019 with aseptic instability of the right total hip arthroplasty and a Paprosky type IIIB acetabular defect. One-stage revision arthroplasty was performed using a custom triflange acetabular component designed from CT data and manufactured from titanium powder using direct metal laser sintering (DMLS). The Harris Hip Score improved from 21 points preoperatively to 82 points at 6 months; the WOMAC score decreased from 73 to 15 points over the same period. No early postoperative complications occurred; mild residual limp related to scarring and gluteal muscle atrophy persisted. An updated review of the 2018–2026 literature confirms that custom additively manufactured implants remain an effective option for restoring limb support and hip function in extensive acetabular defects and pelvic discontinuity, although dislocation, nerve injury and infection remain relevant risks requiring further refinement of planning, fixation and stability strategies.

25 August 2026 in N.N. Priorov Journal of Traumatology and Orthopedics
Verified
Journal Article
Open access
PDF file
IFIlya V. Frolikov
Ilya V. Frolikov
ФВФроликов Илья Вадимович
Фроликов Илья Вадимович
SKSergey V. Kagramanov
Sergey V. Kagramanov
КВКаграманов Сергей Владимирович
Каграманов Сергей Владимирович
NZNikolay Zagorodniy
Nikolay Zagorodniy
АРАбдуллин Марат Ренатович
Абдуллин Марат Ренатович
Dysplastic coxarthrosis represents one of the most challenging issues in modern orthopedics, accounting for 48.4% of all coxarthrosis cases in patients under 50 years of age. Anatomical deformities in hip dysplasia create significant technical difficulties during arthroplasty, leading to a higher incidence of complications. The key problem of this pathology is the progressive degeneration of the joint: incongruence of the femoral head and acetabulum of the hip joint, which causes early wear of the articular surfaces , subluxation/dislocation of the hip, limb shortening, and compensatory postural disorders. The prevalence of hip dysplasia is 2%–3% among newborns, with 30% of patients with hip dysplasia developing secondary osteoarthritis by the age of 40, and, in the absence of positive response from conservative therapy, requiring total hip arthroplasty. Total hip arthroplasty for dysplastic coxarthrosis remains a technically complex operation due to pronounced anatomical changes: hypoplasia of the acetabulum, bone deficiency in various planes, a narrow femoral canal, and increased anteversion of the femur. Over the past two decades, there has been an evolution in computer technologies in total hip arthroplasty from simple navigation systems to advanced robotic platforms. For hip arthroplasty, modern robotic systems use 3D planning based on computed tomography data, which allows minimizing positioning errors of the cup to ≤1° and ≤1 mm, taking into account the patient’s individual anatomical features. The relevance of implementing robotic systems for patients with dysplastic coxarthrosis is confirmed by studies demonstrating a reduction in the incidence of dislocations in robot-assisted operations, as well as a decrease in the risk of aseptic instability, restoration of biomechanical parameters: offset, lower limb length, acetabular reaming while minimizing potential bone defects in the acetabulum for subsequent revision intervention.