Load unbalance in electric distribution systems is unavoidable. Unbalanced load currents will lead to negative sequence (NS) voltages that may damage electric equipment. Unbalanced power flow analysis is a common tool to detect and mitigate NS voltage issues and requires accurate models of grid components. While traditional source models are available, grid-forming (GFM) inverter models are not well developed. GFM inverters implement various control strategies, which affect their power flow models. In this article, a novel GFM inverter model considering control effects is proposed. We show that for some control methods, unbalanced system loading will lead to unbalanced terminal voltages of the GFM inverters, which are modeled through an equivalent negative sequence impedance. The proposed models are initially validated using a simple test circuit. Then, they are applied in the power flow analysis on the IEEE 13-bus and 34-bus systems to demonstrate the accuracy improvement over the state-of-the-art. Using time-domain simulations as benchmarks, we show that the proposed models reduce the calculation error of negative sequence voltages by at least 25% in unbalanced distribution systems.
Distributed energy resources (DERs) and microgrids have seen tremendous growth and research activities in recent years. Flexible DERs and asynchronous microgrids (ASMG) can have many system-level benefits over fixed DERs and conventional microgrids. The key enabler for flexible DERs and ASMG is a power converter based power conditioning system (PCS) as the interface between DERs/microgrids and the medium voltage (MV) distribution grid. High voltage (HV, >3.3 kV) silicon carbide (SiC) based MV converter is now a promising solution for the PCS. This article presents development and testing of a 10 kV SiC MOSFET based MV PCS for 13.8 kV ASMG. MV PCS converter design addressing high dv/dt issue generated by fast switching of the 10 kV SiC MOSFET is presented. The developed PCS is successfully tested at 25 kV dc 13.8 kV ac voltages and 100 kVA power. Grid support functions are also demonstrated with the developed PCS prototype and hardware tests beds, validating HV SiC converter benefits for ASMG.
This paper presents a desat protection scheme with ultrafast response for high voltage (>3.3 kV) SiC MOSFETs. Its working principle is the same as the conventional desat protection designed for high voltage SiC MOSFETs, yet its blanking time is implemented by fully considering the influence of high negative dvds/dt during the fast turn-on transient. With the same circuitry as the conventional desat protection, the proposed protection scheme can significantly shorten the response time of the desat protection when it is used to protect high voltage SiC MOSFETs. In addition, the proposed protection scheme with ultrafast response features strong noise immunity, low-cost, and simple implementation. By taking advantage of the high dv/dt during the normal turn-on transients, the proposed protection scheme can be even faster when the MOSFET has faster switching speed. Design details and the response speed analysis under various short circuit faults are presented in detail. A half bridge phase leg based on discrete 10 kV/20 A SiC MOSFETs is built to demonstrate the proposed protection scheme. Experimental results at 6.5 kV validate the ultrafast response (115 ns response time under a hard switching fault (HSF), 155 ns response time under a fault under load (FUL)) and strong noise immunity of the proposed desat protection scheme.
This paper discusses the design, development, and testing of a flexible combined heat and power (F-CHP) system. It includes two parts: the power conditioning system (PCS) converter, which connects the system to the grid and is the key component to provide grid support services, and the F-CHP central controller, which accommodates the control of local sources, local loads, and the PCS converter. The functions and structures of the central controller are discussed. The central controller’s system-level performances are verified with hardware-in-the-loop (HIL) tests, and the mode transition and grid transient performances are validated with power electronic converter-based hardware testbed (HTB) tests. The PCS converter is designed with 10 kV SiC MOSFETs. The grid requirements are considered in the 13.8 kV/1 MW PCS converter design, and the impact of different requirements on the converter design is identified. Also, converter scalability is studied with the paralleling operation. Two 13.8 kV/100 kW converter prototypes are developed to verify the converter design and scalability. The second prototype is an improved design of the first one; the volume is reduced by 49% and the efficiency at the rated output power is increased from 96.4% to 98.4%. The test results of the converter performances, grid support functions, and parallel operation are also discussed.
The dynamic boundary concept enables more flexible and efficient operation of microgrids with distributed energy resources (DER) that are intermittent in nature. As the integration of renewables continues to accelerate, an adaptive power management module that enables dynamic boundary operations in microgrids with an increasing number of source locations is essential for the fast and low-cost deployment of microgrid controllers. The power management module introduced in this paper is capable of handling the increased complexity in topological variations and transitions stemming from dynamic boundaries and multiple source locations. This includes real-time operation of multiple islands with dynamic boundaries, initiation of topological transitions (merging and separation of islands), and automatic source coordination for power sharing and frequency regulation. All functions in the power management module are designed to be automatically adaptable to arbitrary microgrids with non-meshed topologies so that the deployment of the controller at new microgrid sites can be expedited with a reduced cost. The module has been implemented on NI’s CompactRIO system as an essential part of an MG controller and tested on a converter-based hardware testbed (HTB). Testing results validated the effectiveness of the algorithms under various operating conditions.