Hiroshi Tojo

Hiroshi Tojo

Auto-generated profile, based on publicly available information

Hiroshi Tojo

National Institutes for Quantum Science and Technology, 801-1 Mukoyama, Naka, Ibaraki 311-0193, Japan

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
HTH. Tojo
H. Tojo
Roberto PasqualottoRoberto Pasqualotto
Roberto Pasqualotto
AFA. Fassina
A. Fassina
LGL. Giudicotti
L. Giudicotti
HSH. Sasao
H. Sasao
NON. Oyama
N. Oyama
An incoherent Thomson scattering diagnostic will be installed in the JT-60SA tokamak to measure electron temperature and electron density profiles. The target radial spatial resolution is 25 mm with 46 spatial channels. The accuracy in electron temperature and density is a few percent at ne = 7.5 × 1019 m−3, which is the expected value in the plasma core. This paper presents the designs of collection optics, fibers with their alignment system, and polychromators. The collection optics overcomes unique issues for superconducting fusion devices, i.e., limited design space, high-temperature measurements, and harsh radiation condition. When in several years the more performing plasma will generate intense nuclear radiation, the lens materials of the optics can be replaced by radiation resistant glasses without major changes in the lens holder. It will prevent transmission degradation and keep stable measurement accuracy.

1 January 2014 in Plasma and Fusion Research
Verified
Journal Article
Open access
HTHiro Togashi
Hiro Togashi
AEAkira Ejiri
Akira Ejiri
MHMakoto Hasegawa
Makoto Hasegawa
JHJunichi Hiratsuka
Junichi Hiratsuka
YNYoshihiko Nagashima
Yoshihiko Nagashima
TTthe TST-2 Team
the TST-2 Team

14 February 2023 in Fusion Engineering and Design
Verified
Journal Article
Closed access
HTHiroshi Tojo
Hiroshi Tojo

1 April 2024 in Journal of Instrumentation
Verified
Journal Article
Closed access
MAM. Akimitsu
M. Akimitsu
YOY. Ohtani
Y. Ohtani
HFH. Funaba
H. Funaba
HTH. Tojo
H. Tojo
FDF.A. D'ISa
F.A. D'ISa
MYM. Yoshida
M. Yoshida
We have developed signal processing routines for the Thomson Scattering measurement, which is planned for use in the next campaign of the JT-60SA large-scale tokamak experiment. This paper provides the data analysis system and its performance evaluated in terms of computation time and error. The sequential routine of determining the scattered light intensity from a simulated signal, including noise data from a 1 Gs/s high-speed sampling digitizer, and determining the electron temperature and density was tested for the first time on an actual machine. The data analysis system ensures that electron temperature and density can be calculated with reasonable relative errors and within a realistic time frame for operations on JT-60SA.

1 September 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
HTH. Tojo
H. Tojo
IYI. Yamada
I. Yamada
RYRyo Yasuhara
Ryo Yasuhara
AEA. Ejiri
A. Ejiri
JHJ. Hiratsuka
J. Hiratsuka
KIK. Itami
K. Itami
This paper evaluates the accuracy of electron temperature measurements and relative transmissivities of double-pass Thomson scattering diagnostics. The electron temperature (Te) is obtained from the ratio of signals from a double-pass scattering system, then relative transmissivities are calculated from the measured Te and intensity of the signals. How accurate the values are depends on the electron temperature (Te) and scattering angle (θ), and therefore the accuracy of the values was evaluated experimentally using the Large Helical Device (LHD) and the Tokyo spherical tokamak-2 (TST-2). Analyzing the data from the TST-2 indicates that a high Te and a large scattering angle (θ) yield accurate values. Indeed, the errors for scattering angle θ = 135° are approximately half of those for θ = 115°. The method of determining the Te in a wide Te range spanning over two orders of magnitude (0.01–1.5 keV) was validated using the experimental results of the LHD and TST-2. A simple method to provide relative transmissivities, which include inputs from collection optics, vacuum window, optical fibers, and polychromators, is also presented. The relative errors were less than approximately 10%. Numerical simulations also indicate that the Te measurements are valid under harsh radiation conditions. This method to obtain Te can be considered for the design of Thomson scattering systems where there is high-performance plasma that generates harsh radiation environments.

1 August 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
FDF. A. D’iSa
F. A. D’iSa
AFA. Fassina
A. Fassina
LGL. Giudicotti
L. Giudicotti
SSS. Soare
S. Soare
HTH. Tojo
H. Tojo
Roberto PasqualottoRoberto Pasqualotto
Roberto Pasqualotto
The mission of the JT-60SA project is to complement ITER’s capabilities by addressing the fundamental physics and engineering challenges necessary to develop a practical and reliable fusion power plant. Diagnostics play a pivotal role in achieving this mission, especially the Thomson Scattering (TS) diagnostic systems developed by a collaborative Japan–EU team. The edge Thomson scattering of JT-60SA is tailored to measure the low field side outer region of the plasma, in particular, to resolve the electron temperature Te and density ne. The collection optics of the edge TS system have a critical role in meeting the required field of view and spatial resolution despite the limited space. This work presents a comprehensive optomechanical design of the optics assembly, whose main features are telecentricity and compactness, highlighting its capabilities. The tests undertaken to verify its performance: focal plane identification, thermal cycle, and magnification, are described.