1 February 2021 in Review of Scientific Instruments
We present the design for a rapid proton energy modulator with radiofrequency accelerator cavities, which can deliver the proton radiation dose to varied depth in human tissues much faster than traditional mechanical beam energy degraders. The proton energy modulator is designed as a multi-cell 1-m long accelerator working at 2.856 GHz. Each individual accelerator cavity is powered by a 400 kW compact klystron to provide an accelerating/decelerating gradient of 30 MV/m. The high gradient is enabled by the individual power coupling regime, which provides a high shunt impedance. Beam dynamics simulations were performed, showing that the energy modulator can provide ±30 MeV of beam energy change for a 150 MeV, 7 mm long (full length) proton bunch, and the total energy spread of 3 MeV is satisfactory to clinical needs. A prototype experiment of a single cell has been built and tested, and the low-power microwave measurement results agree very well with simulations. The energy modulator is optimized for the 150 MeV cyclotron proton beam, while this approach can work with different beam energies.
13 February 2018 in IEEE Transactions on Electron Devices
L3 Electron Devices has developed a high-power multibeam inductive output tube (MBIOT) for the European Spallation Source. In July 2014, L3 was awarded a contract for the design, manufacture, and test of a 1.2 MW, 704.42 MHz, pulsed power MBIOT. In October 2016, factory acceptance testing of the L6200 1.2-MW MBIOT was completed at L3 Electron Devices. In October 2017, site acceptance testing was successfully completed at the European Organization for Nuclear Research (CERN). The ten-beam, permanent magnet-focused device meets the maximum 1.2-MW output power specification with a dc-to-RF efficiency of 70%; efficiency is maintained above 60% down to 650 kW. Factory testing at L3 was limited to a cathode voltage of 43.6 kV and a maximum pulsewidth of 200 μs. The CERN MBIOT test stand enabled operation at the preferred cathode voltage of 45 kV and at the full pulsewidth of 4 ms. The CERN test stand also offered the ability to individually adjust the filament voltage and bias voltage to each gun, which was not possible with the L3 test configuration. The CERN test stand and MBIOT are currently being prepared to demonstrate long-duration operation.
5 August 2020 in IEEE Transactions on Electron Devices
In this article, the design, characterization, and manufacture of a circuit for a W-band, ultracompact continuous wave sheet beam klystron are described. This klystron, aiming to produce more than 1.5-kW output power, operates at a comparatively low voltage benefiting the device size and extending its application space. However, a lower operation voltage adversely affects the beam-gap interaction efficiency. Two multigap output cavities have been employed to achieve a higher beam interaction efficiency without introducing additional competing modes or shrinking the interval between the operation mode and competing mode. Inspired by the resynchronization technology, the second output cavity can be optimized for the spent beam from the first output cavity. Comprising a single cavity output structure, the circuit efficiency of this double output cavity circuit is increased from 2.37% to 4.96%. In this circuit, electromagnetic modeling and design have been optimized to avoid complicated structures which are constrained by current mechanical design and manufacturing techniques. The MAGIC simulation shows that, driven by a 1-W RF signal, this circuit can extract more than 1.7-kW output power from a 35-kV, 1-A beam. A prototype single output cavity circuit has been designed and manufactured to determine the required machining tolerances for the final double output cavity circuit.