Studies of clinical populations that combine MRI data generated at multiple sites are increasingly common. The Canadian Biomarker Integration Network in Depression (CAN-BIND; www.canbind.ca ) is a national depression research program that includes multimodal neuroimaging collected at several sites across Canada. The purpose of the current paper is to provide detailed information on the imaging protocols used in a number of CAN-BIND studies. The CAN-BIND program implemented a series of platform-specific MRI protocols, including a suite of prescribed structural and functional MRI sequences supported by real-time monitoring for adherence and quality control. The imaging data are retained in an established informatics and databasing platform. Approximately 1300 participants are being recruited, including almost 1000 with depression. These include participants treated with antidepressant medications, transcranial magnetic stimulation, cognitive behavioural therapy and cognitive remediation therapy. Our ability to analyze the large number of imaging variables available may be limited by the sample size of the substudies. The CAN-BIND program includes a multimodal imaging database supported by extensive clinical, demographic, neuropsychological and biological data from people with major depression. It is a resource for Canadian investigators who are interested in understanding whether aspects of neuroimaging — alone or in combination with other variables — can predict the outcomes of various treatment modalities.
High-speed dual fluoroscopy is a noninvasive imaging technology for three-dimensional skeletal kinematics analysis that finds numerous biomechanical applications. Accurate reconstruction of bone translations and rotations from dual-fluoroscopic data requires accurate calibration of the imaging geometry and the many imaging distortions that corrupt the data. Direct linear transformation methods are commonly applied for performing calibration using a two-step process that suffers from a number of potential shortcomings including that each X-ray source and corresponding camera must be calibrated separately. Consequently, the true imaging set-up and the constraints it presents are not incorporated during calibration. A method to overcome such drawbacks is the single-step self-calibrating bundle adjustment method. This procedure, based on the collinearity principle augmented with imaging distortion models and geometric constraints, has been developed and is reported herein. Its efficacy is shown with a carefully controlled experiment comprising 300 image pairs with 48 507 image points. Application of all geometric constraints and a 31 parameter distortion model resulted in up to 91% improvement in terms of precision (model fit) and up to 71% improvement in terms of 3-D point reconstruction accuracy (0.3-0.4 mm). The accuracy of distance reconstruction was improved from 0.3±2.0 mm to 0.2 ±1.1 mm and angle reconstruction accuracy was improved from -0.03±0.55° to 0.01±0.06°. Such positioning accuracy will allow for the accurate quantification of in vivo arthrokinematics crucial for skeletal biomechanics investigations.
Objectives: Numerous complications following total knee replacement (TKR) relate to the patellofemoral (PF) joint, including pain and patellar maltracking, yet the options for in vivo imaging of the PF joint are limited, especially after TKR. We propose a novel sequential biplane radiological method that permits accurate tracking of the PF and tibiofemoral (TF) joints throughout the range of movement under weightbearing, and test it in knees pre- and post-arthroplasty. Methods: A total of three knees with end-stage osteoarthritis and three knees that had undergone TKR at more than one year’s follow-up were investigated. In each knee, sequential biplane radiological images were acquired from the sagittal direction (i.e. horizontal X-ray source and 10° below horizontal) for a sequence of eight flexion angles. Three-dimensional implant or bone models were matched to the biplane images to compute the six degrees of freedom of PF tracking and TF kinematics, and other clinical measures. Results: The mean and standard deviation for the six degrees of freedom of PF tracking and TF kinematics were computed. TF and PF kinematics were highly accurate (< 0.9 mm, < 0.6°) and repeatable. Conclusions: The developed method permitted measuring of in vivo PF tracking and TF kinematics before and after TKR throughout the range of movement. This method could be a useful tool for investigating differences between cohorts of patients (e.g., with and without pain) impacting clinical decision-making regarding surgical technique, revision surgery or implant design.