Teenu Techela Davis

Teenu Techela Davis

Auto-generated profile, based on publicly available information

Teenu Techela Davis

Electrical, Indian Institute of Technology Roorkee, 30112 Roorkee, Uttarakhand India

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
TDTeenu Techela Davis
Teenu Techela Davis
ADAnubrata Dey
Anubrata Dey
Enhancement of DC bus voltage utilization for a five-level inverter with single DC source and capacitor fed H-bridge (CHB) units is investigated in this paper. A carrier-based modulation technique is used for boosting the DC bus utilization, which is established by providing detailed mathematical analysis. The increase in DC bus voltage utilization owes to the pole voltage redundancies offered by CHB units. The floating capacitors of H-bridge units are balanced using the switching state redundancies of pole voltage levels. The aforementioned modulation technique allows the inverter to enhance the DC bus utilization from 0.577Vdc to 0.63Vdc under unity power factor. This enhancement is obtained in the linear modulation range without increasing the DC bus voltage and thus, the inverter can operate without the presence of low order harmonics in its phase voltages. The strength of this paper lies in its detailed mathematical analysis for finding out the limiting modulation index and power factor condition in the light of floating capacitor voltage balancing issue. Simulation as well as experimental verification of the modulation scheme is carried out on an induction motor (IM) drive under various operating conditions.

5 May 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
RGRicha Goel
Richa Goel
TDTeenu Techela Davis
Teenu Techela Davis
ADAnubrata Dey
Anubrata Dey
This article proposes a single dc source based hybrid three-phase thirteen-level inverter suitable for medium voltage applications. The multilevel structure is composed of 3-level T-type NPC, half bridge and 3-level Flying capacitor converter with optimal switch count and high dc bus voltage utilization as high as 0.63 times of the dc link voltage. This requires a special attention to a novel capacitor balancing method using redundant switching states in order to operate at any power factor under grid connected mode. A unified Common-mode voltage is injected in the carrier based PWM technique to maintain the voltage balance in dc link capacitors as well as floating capacitors. Simulation results are presented under different operating conditions that includes unity power factor operation with passive load as well as grid connected inverter mode. The performance of the proposed multilevel inverter in the grid connected mode is also validated with experimental results using a lab prototype.

2 April 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
TDTeenu Techela Davis
Teenu Techela Davis
ADAnubrata Dey
Anubrata Dey
In this paper, a neutral point (NP) voltage balancing scheme suitable for three phase 5-level ANPC and TNPC inverters is discussed. Carrier based pulse width modulation is used for the balancing of DC link capacitors and floating capacitors (FC) in the inverter. The FC voltages are regulated with the help of redundant switching states of pole voltage levels and the DC link capacitor voltages are controlled using zero-sequence voltage injection. Though the balancing approaches are different for DC link capacitors and FCs, they are not decoupled from each other. This is due to the effect of certain redundant switching states used for FC balancing causing NP voltage variation. To address this issue, the redundant state time ratio is estimated online every sample and based on this dynamic time ratio, an optimal relationship between neutral current and zero-sequence voltage is established. It is found that use of dynamic time ratio helps in achieving better transient performance than that of generally adopted fixed time ratio. Simulation and experimental results prove that the proposed balancing scheme works well under all operating conditions and exhibits fast and stable transient performance.

25 March 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TDTeenu Techela Davis
Teenu Techela Davis
TJThomas Joseph
Thomas Joseph
ADAnubrata Dey
Anubrata Dey
This paper proposes a novel floating capacitor (FC) and dc link capacitor voltage balancing scheme for a single source three-phase 9-level inverter with reduced part count. Although nine levels are generated by keeping the dc link capacitor voltage to FC voltage ratio as 3:1, it comes with complete absence of any useful pole voltage redundancies. Therefore, the conventionally adopted redundant state switching based pulse width modulation technique cannot be applied for FC voltage balancing. Hence, a novel carrier based modulation scheme is proposed here, which addresses the issue of FC voltage balancing by safely clamping the modulating reference to pole voltage levels that aid in FC voltage balancing. The dc link capacitor voltages are also balanced using an unique way suitable for this inverter having non-redundant characteristics. Simulation and experimental results verify the capability of proposed balancing scheme for the optimized 9-level inverter under different modulation and load conditions. It is found that a maximum fundamental phase peak voltage of 0.607 times dc link voltage (at 0.91 modulation index) can be achieved at unity power factor and thus utilizing the dc bus of the inverter effectively.

12 September 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TDTeenu Techela Davis
Teenu Techela Davis
ADAnubrata Dey
Anubrata Dey
Two novel floating capacitor voltage balancing schemes are proposed in this paper, which enhances linear modulation range of single source 7-level inverters having floating capacitor fed H-bridge units. Extreme pole voltage levels associated to cascaded H-bridge units can be used for enhancing DC bus utilization. But, these pole voltage levels lack redundant switching states that limits the linear modulation range for which floating capacitor voltages remain balanced. In recent times, a few literature have addressed the issue of balancing these capacitor voltages by employing appropriate modulation schemes that enhances the modulation range of inverter to a certain extent. The proposed balancing schemes further extend the linear modulation range by adding a suitable common-mode offset to reference signals. The addition of a predefined low frequency offset and an online calculated dynamic offset is proposed here that helps in extending the modulation range to 0.84 and 0.85 respectively. Under these schemes, the DC bus utilization can reach up to 0.637 $V_{dc}$ at unity power factor where, $V_{dc}$ is input voltage of the single source inverters. Three well-established optimized 7-level inverters are used to analyze these schemes and its effectiveness is demonstrated using simulation and experimental results at different modulation and load conditions.

1 October 2019
Verified
Conference Paper
Closed access
TDTeenu Techela Davis
Teenu Techela Davis
PGPranjal Mathu Gajare
Pranjal Mathu Gajare
ADAnubrata Dey
Anubrata Dey
A three-phase 9-level multilevel inverter (MLI) using single dc source and reduced device count is discussed in this paper. The hybrid MLI has a 3-level T-type inverter cascaded by a floating capacitor (FC) fed H-bridge (HB) unit in each of the phase. The number of pole voltage levels are dependent on the ratio of dc link capacitor voltage with respect to the FC voltage. The ratio being 3:1, the inverter can generate nine output levels but with lack of pole voltage redundancies. Thus the commonly adopted redundant state switching method cannot be used for FC voltage balancing. A novel carrier based modulation technique is proposed here to address this issue. This technique balances the FC voltage by shifting the phase reference to a nearest carrier region whose voltage levels aids in achieving the desired FC voltage. The voltage balancing capability of the proposed technique is tested under different operating conditions and is illustrated using simulation results. It is found that the FC voltages remain stable during transient and steady-state conditions of the inverter and the inverter is able to provide a dc bus utilization of 0.607 times the dc link voltage at unity power factor.