Pranjal Mathu Gajare

Pranjal Mathu Gajare

Auto-generated profile, based on publicly available information

Pranjal Mathu Gajare

Center for Distributed Energy, Georgia Institute of Technology, Atlanta, GA, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZZZexian Zeng
Zexian Zeng
PGPranjal M. Gajare
Pranjal M. Gajare
DDDeepak Divan
Deepak Divan
MSMaryam Saeedifard
Maryam Saeedifard
The influence of dc-side dynamics in grid-forming inverters has emerged as a critical area of study due to its implications for stability and control. A key yet unresolved question in the literature concerns the choice between measured and nominal dc voltage when determining the modulation index for the inverter's output voltage. This letter provides new insights into the distinct dynamic behaviors associated with these approaches. Through theoretical analysis, it demonstrates that the use of nominal dc voltage introduces unique low-frequency dynamics, leading to a previously unreported kind of subsynchronous oscillation. These oscillations, rooted in the interaction between dc-side dynamics and grid-forming control, pose potential challenges for system stability. Theoretical predictions are validated through hardware-in-the-loop studies.

19 May 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
PGPranjal M. Gajare
Pranjal M. Gajare
JBJoseph Benzaquen
Joseph Benzaquen
DDDeepak Divan
Deepak Divan
Grid-forming (GFM) inverters, like synchronous generators (SGs), form voltage at their terminals and are crucial for enabling high renewable energy integration. Most GFM controllers mimic the power-synchronization characteristics of the SG rotor’s swing dynamics to synchronize with the system. However, GFM inverters differ significantly from SGs in both dynamics and control. This paper systematically explores these differences. The analysis reveals that the coupling between steady-state and transient performance in traditional GFM controllers, influenced by the active power-frequency droop gain, along with the absence of features like large stator inductance, damper windings, and power system stabilizers, may result in SGs having superior disturbance rejection in the small-signal domain. Building on these insights, a novel GFM control scheme, Angle Restoration Control (ARC), with improved disturbance rejection performance, is proposed. A comparative stability analysis is performed to evaluate the robustness of the proposed scheme against conventional droop GFM controls under various grid conditions. Finally, the effectiveness of the proposed control method is further validated through simulations and real-time hardware-in-the-loop testing in diverse power system scenarios.

8 June 2023 in Electric Power Systems Research
Verified
Journal Article
Closed access
RCRupak Chakraborty
Rupak Chakraborty
PGPranjal Mathu Gajare
Pranjal Mathu Gajare
RCRupam Chaki
Rupam Chaki
ADAnubrata Dey
Anubrata Dey

1 October 2019
Verified
Conference Paper
Closed access
TDTeenu Techela Davis
Teenu Techela Davis
PGPranjal Mathu Gajare
Pranjal Mathu Gajare
ADAnubrata Dey
Anubrata Dey
A three-phase 9-level multilevel inverter (MLI) using single dc source and reduced device count is discussed in this paper. The hybrid MLI has a 3-level T-type inverter cascaded by a floating capacitor (FC) fed H-bridge (HB) unit in each of the phase. The number of pole voltage levels are dependent on the ratio of dc link capacitor voltage with respect to the FC voltage. The ratio being 3:1, the inverter can generate nine output levels but with lack of pole voltage redundancies. Thus the commonly adopted redundant state switching method cannot be used for FC voltage balancing. A novel carrier based modulation technique is proposed here to address this issue. This technique balances the FC voltage by shifting the phase reference to a nearest carrier region whose voltage levels aids in achieving the desired FC voltage. The voltage balancing capability of the proposed technique is tested under different operating conditions and is illustrated using simulation results. It is found that the FC voltages remain stable during transient and steady-state conditions of the inverter and the inverter is able to provide a dc bus utilization of 0.607 times the dc link voltage at unity power factor.

27 May 2025 in TechRxiv
Verified
Preprint
Open access
PGPranjal M. Gajare
Pranjal M. Gajare
JBJoseph Benzaquen
Joseph Benzaquen
DDDeepak Divan
Deepak Divan
Grid-forming (GFM) inverters, like synchronous generators (SGs), form voltage at their terminals and are considered crucial for enabling high renewable energy integration. Most GFM controllers mimic the power-synchronization characteristics of the SG rotor's swing dynamics to synchronize with the system. However, GFM inverters differ significantly from SGs in both design and control. This paper systematically explores these differences. The analysis reveals that the coupling between steady-state and transient performance in traditional GFM controllers, both influenced by the active power-frequency droop gain, along with the absence of features like large stator inductance, damper windings, and power system stabilizers (PSS), may result in SGs having superior disturbance rejection in the small-signal domain. Building on these insights, a novel GFM control technique with improved disturbance rejection performance is proposed. A comparative stability analysis is performed to evaluate the robustness of the proposed technique against conventional GFM controls under various grid conditions. The effectiveness of the proposed control method is further validated through MATLAB/Simulink simulations and real-time hardware-in-the-loop testing in diverse power system scenarios.

8 October 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
KAKartavya Agarwal
Kartavya Agarwal
PGPranjal Gajare
Pranjal Gajare
JBJoseph Benzaquen
Joseph Benzaquen
DDDeepak Divan
Deepak Divan
The increasing penetration of inverter-based resources (IBRs) in power systems is radically challenging existing overcurrent protection practices. Traditional overcurrent protection devices may not be equipped to provide sensitive and selective fault tripping capabilities due to the significantly limited and variable fault current contributions of IBRs. This article presents an Inverter Fault Current Multiplier (IFCM) architecture for grid-interactive power converters. The IFCM is a novel power electronics platform integrated with semiconductor switches and a transformer that amplifies the fault current contribution from IBRs to trip conventional protection devices. Furthermore, integrated sensors and controllers in the IFCM packaging facilitate a decentralized operating mechanism that allows it to be integrated with a power system's existing overcurrent protection infrastructure, eliminating the need for resource-intensive system upgrade efforts. This article illustrates the operating mechanism of the IFCM and its impact on meeting the overcurrent protection needs of an IBR-rich grid. Hardware results from a lab-scale prototype and finite-element simulation validation of the concept are also provided at residential voltage levels, demonstrating the feasibility of the IFCM.