Pimpet Sratong-On

Pimpet Sratong-On

Auto-generated profile, based on publicly available information

Pimpet Sratong-On

Composite Materials and Lightweight Structures Laboratory, Faculty of Engineering, Thai-Nichi Institute of Technology, Bangkok, 10250 Thailand

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PSP. Sratong-On
P. Sratong-On
Volodymyr ChernenkoVolodymyr Chernenko
Volodymyr Chernenko
JFJ. Feuchtwanger
J. Feuchtwanger
Hideki HosodaHideki Hosoda
Hideki Hosoda
Single crystalline Ni-Mn-Ga is well known as a prototype ferromagnetic shape memory alloy (FSMA) exhibiting a giant magnetic field-induced strain (MFIS), up to 12%, due to the magnetically driven twin boundary rearrangement. The large stroke and fast magnetomechanical response make it important for actuators and sensors. Polycrystalline Ni-Mn-Ga is inexpensive and technologically easy accessible, but constrains from the grain boundaries inhibit the twin boundary motion, whereby a very low MFIS is observed. Here, we have shown for the first time that a polycrystalline Ni-Mn-Ga can be split into the magnetostrain-active single grains which, being specially assembled in a silicone polymer matrix, caused large and fully reversible MFIS of the resulting composite. We termed the unique reversibility of a large MFIS of the composite as the magnetic field-induced rubber-like behavior. The magnetostrain of individual particles was explored by the X-ray μCT 3D imaging. The results suggest novel solutions for development of the low cost magnetic actuators and sensors for haptic applications.

1 January 2022 in Scripta Materialia
Verified
Journal Article
Closed access
WCWan-Ting Chiu
Wan-Ting Chiu
PSPimpet Sratong-On
Pimpet Sratong-On
MTMasaki Tahara
Masaki Tahara
VCVolodymyr Chernenko
Volodymyr Chernenko
HHHideki Hosoda
Hideki Hosoda

3 March 2023 in Heliyon
Verified
Journal Article
Open access
NLNuttapol Limjeerajarus
Nuttapol Limjeerajarus
PSPimpet Sratong-On
Pimpet Sratong-On
PDPhetcharat Dhammayannarangsi
Phetcharat Dhammayannarangsi
KTKevin A. Tompkins
Kevin A. Tompkins
PKPaksinee Kamolratanakul
Paksinee Kamolratanakul
CLChalida Nakalekha Limjeerajarus
Chalida Nakalekha Limjeerajarus
There are two commonly cited modulus of elasticity of the human periodontal ligament (EPDL), i.e., 6.89 ✕ 10-5 GPa (E1) and 6.89 ✕ 10-2 GPa (E2), which are exactly 1000-fold different from each other. This study aims to clarify the ambiguity of the two EPDL used for simulations and determine a more accurate EPDL value of human first premolars using experimental and simulation approaches. Numerical simulations using finite element analysis were performed to analyze PDL deformation under an average Asian occlusal force. To confirm the results, simple and multi-component, true-scale 3D models of a human first premolar were used in the simulations. Finally, a compression test using a universal testing machine on PDL specimens was conducted to identify the compressive EPDL of human first premolars. The simulation results from both models revealed that E1 was inaccurate, because it resulted in excessive PDL deformation under the average occlusal force, which should not occur during mastication. Although the E2 did not lead to excessive PDL deformation, it was obtained by an error in unit conversion with no scientific backing. In contrast, the compression test results indicated that the compressive EPDL was 9.64 ✕ 10-4 GPa (E3). In the simulation, E3 did not cause excessive PDL deformation. The simulation results demonstrated that both commonly cited EPDL values (E1 and E2) were incorrect. Based on the experimental and simulation results, the average compressive EPDL of 9.64 ✕ 10-4 GPa is proposed as a more accurate value for human first premolars. The proposed more accurate EPDL would contribute to more precise and reliable FEA simulation results and provide a better understanding of the stress distribution and deformation of dental materials, which will be beneficial to precision dentistry, orthodontics and restoration designs.

30 December 2022 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
WCWan-Ting Chiu
Wan-Ting Chiu
PSPimpet Sratong-On
Pimpet Sratong-On
TCTso-Fu Mark Chang
Tso-Fu Mark Chang
MTMasaki Tahara
Masaki Tahara
MSMasato Sone
Masato Sone
HHHideki Hosoda
Hideki Hosoda

5 January 2023 in Scripta Materialia
Verified
Journal Article
Closed access
WCWan-Ting Chiu
Wan-Ting Chiu
PSPimpet Sratong-On
Pimpet Sratong-On
MTMasaki Tahara
Masaki Tahara
Volodymyr ChernenkoVolodymyr Chernenko
Volodymyr Chernenko
HHHideki Hosoda
Hideki Hosoda

25 July 2018 in Smart Materials and Structures
Verified
Journal Article
Closed access
PSP Sratong-On
P Sratong-On
MTM Tahara
M Tahara
TIT Inamura
T Inamura
Volodymyr ChernenkoVolodymyr Chernenko
Volodymyr Chernenko
Hideki HosodaHideki Hosoda
Hideki Hosoda
Ni–Mn–Ga particles/silicone composite was fabricated for a mechanical investigation. The characteristic twinning structure of particles and soft enough matrix provide the conditions enabling the possibility for particles to deform by the twin boundaries motion mechanism under applied stress and/or magnetic field. On the macroscopic scale, the large hysteretic loops in the stress–strain curves for composite evidence about its high energy absorption capability. On the microscopic scale, the in situ compression test was performed using an x-ray micro-computed tomography to study the individual deformation of particles. The strain behavior of individual particles in the three different configuration of groups was disclosed as a function of the compression degree of composite showing large reversible deformation of particles, signature of the twin structure rearrangement. The unusual drop of particles strains at very high compression degrees of composite is explained in terms of the non-uniform stress field in polymer produced by the neighbor particles interactions affected by barreling. The obtained results support the reason that the particles in composite should be arranged in single chains to avoid their interaction which is a way to improve the composite performance in the mechanical damping and magnetic actuator applications.