21 October 2021 in IEEE Transactions on Smart Grid
Due to the inherent characteristics of inverter- interfaced distributed generators (IIDG), their fault responses are different from those of conventional synchronous generators. Investigating fault responses of IIDGs and establishing their fault models will benefit the fault calculation and protection scheme design for microgrids. This paper focuses on grid-forming IIDGs (GFGs) and hierarchically analyzes their fault characteristics under symmetrical and asymmetrical faults. A generic fault model of GFG, which covers both the transient- and steady-state, is proposed. Impacts of the transfer function of controllers, the current limiting module, and the fluctuation of DC-link voltage on GFG’s transient- and steady-state fault responses are respectively investigated. The influence of GFG’s topology is also considered, and both three-phase three-wire and three-phase four-wire GFGs are covered in the fault analysis. Model parameters calculation methods for all kinds of fault conditions are presented. It is found that the fault type, the fault severity, and the response speed of the DC power regulator all have significant impacts on GFG’s fault responses. The fault analysis and fault model are verified by simulation results in MATLAB/Simulink.
2 September 2024 in IEEE Transactions on Smart Grid
With the increasing penetration of inverter interfaced distributed generators (IIDGs) in microgrids, traditional protection schemes are difficult to cope with the complexities of microgrids. Harmonic-injected protection schemes based on power electronic devices can simplify the harmonic component equivalent network of the microgrid into a single-source radial structure. However, the performance of these schemes is degraded by the shunt effect of the non-harmonic injection source IIDGs and the utility grid. This paper focuses on the active protection method for microgrids based on harmonic injection. A fault control strategy based on harmonic current control and principles for PCC filter parameter design are proposed to address the shunt effect. With the proposed strategy, harmonic currents of varying frequencies are injected into the microgrid by the IIDGs, and the major portion of the injected harmonic currents can flow to the fault point. By analyzing the fault characteristics, a fault location method based on harmonic injection is proposed. Finally, simulation analysis is carried out on MATLAB/Simulink platform, and the effectiveness of the proposed active protection scheme is verified by the results.
26 July 2025 in Electric Power Systems Research
19 January 2024 in IEEE Transactions on Smart Grid
Fault modeling of inverter-interfaced distributed generators (IIDGs) is the basis of power system fault calculation and protection scheme design. Due to its inherent properties and flexible control strategy, analyzing the transient-state fault responses of droop-controlled IIDG is difficult, and an analytical fault model has yet to be proposed. This work establishes a controlled voltage source-based fault equivalent model of droop-controlled IIDG in synchronous reference frame to address this research gap. The impacts of droop characteristics, virtual impedance, double-closed-loop controller, current limiting, and low-voltage-ride-through requirements are all considered, and the obtained model can cover both the transient- and steady-state fault responses. An IIDG clustering method based on the equivalent admittance matrix of the grid is also proposed, which lays the groundwork for model reduction. A corresponding model aggregation method is then provided. With this, the complexity of fault analysis for peer-to-peer controlled distributed power systems can be significantly reduced. The scheme proposed in this paper is verified by simulation experiments in PSCAD/EMTDC software.
5 February 2025 in Electric Power Systems Research
20 November 2025 in Renewable and Sustainable Energy Reviews