Luis Fernando Donis-Rabanales

Luis Fernando Donis-Rabanales

Auto-generated profile, based on publicly available information

Luis Fernando Donis-Rabanales

Facultad de Ingeniería, Universidad Nacional Autónoma de México, Circuito Escolar, Ciudad Universitaria, 04510 Mexico City, Mexico

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2023
Verified
Book Chapter
Closed access
MGMarisela González
Marisela González
ACAlberto Caballero-Ruiz
Alberto Caballero-Ruiz
LDLuis Fernando Donis-Rabanales
Luis Fernando Donis-Rabanales
JAJorge Armando Jiménez Avalos
Jorge Armando Jiménez Avalos
AGAlberto Gutiérrez-Becerra
Alberto Gutiérrez-Becerra
Zaira Yunuen Garcia CarvajalZaira Yunuen Garcia Carvajal
Zaira Yunuen Garcia Carvajal

16 June 2023
Verified
Book Chapter
Closed access
AAAzka Akhlaq
Azka Akhlaq
SASibgha Altaf
Sibgha Altaf
JAJuliana Heloisa Pinê Américo-Pinheiro
Juliana Heloisa Pinê Américo-Pinheiro
RARuby Angurana
Ruby Angurana
KAKalirajan Arunachalam
Kalirajan Arunachalam
AWAtif Khurshid Wani
Atif Khurshid Wani

12 January 2026 in International Journal of Pharmaceutics
Verified
Journal Article
Open access
IMI. Martínez-Camacho
I. Martínez-Camacho
LDL.F. Donis-Rabanales
L.F. Donis-Rabanales
SCS. Cortés-Lagunes
S. Cortés-Lagunes
Juan Carlos Durán-ÁlvarezJuan Carlos Durán-Álvarez
Juan Carlos Durán-Álvarez
MCM.S. Córdova-Aguilar
M.S. Córdova-Aguilar
Gabriel AscanioGabriel Ascanio
Gabriel Ascanio
A new device has been developed to examine how pharmaceutical tablets dissolve under conditions very similar to those in the human stomach. For that purpose, Prednisone USP compendial standard tablets were dissolved in two different apparatuses. On one side, a distal gastric simulator, known as the in vitro Distal Gastric Simulator (IV-DGS), was used. This simulator closely replicates the physiological conditions of the human stomach. It can mimic its operating environment, including peristaltic movement at 3 cycles per minute and an average maximum pressure of about 25 mm Hg. The results from the gastric simulator were compared with the dissolution rates measured using the United States Pharmacopeia-approved apparatus 2. The results show that after 12 min, the USP Apparatus 2 achieved 71.5% dissolution, while the IV-DGS reached 24.9%, indicating a slower dissolution rate but a more realistic gastric mixing. The dissolution data from both systems were modeled using a first-order and a Weibull model, with the latter providing a better fit. Although the results are not entirely comparable with USP 2, the gastric simulator offers a much more realistic alternative for in vitro drug dissolution studies.