1 December 2015 in Dentomaxillofacial Radiology
Objectives: To investigate the effect of tube current-exposure time (mAs) reduction on clinical and technical image quality for different CBCT scanners, and to determine preliminary minimally acceptable values for the mAs and contrast-to-noise ratio (CNR) in CBCT. Methods: A polymethyl methacrylate (PMMA) phantom and an anthropomorphic skull phantom,, containing a human skeleton embedded in polyurethane, were scanned using four CBCT devices, including seven exposure protocols. For all protocols, the mAs was varied within the selectable range. Using the PMMA phantom, the CNRAIR was measured and corrected for voxel size. Eight axial slices and one coronal slice showing various anatomical landmarks were selected for each CBCT scan of the skull phantom. The slices were presented to six dentomaxillofacial radiologists, providing scores for various anatomical and diagnostic parameters. Results: A hyperbolic relationship was seen between CNRAIR and mAs Similarly, a gradual reduction in clinical image quality was seen at lower mAs values; however, for several protocols, image quality remained acceptable for a moderate or large mAs reduction compared with the standard exposure setting, depending on the clinical application. The relationship between mAs, CNRAIR and observer scores was different for each CBCT device. Minimally acceptable values for mAs were between 9 and 70, depending on the criterion and clinical application. Conclusions: Although noise increased at a lower mAs, clinical image quality often remained acceptable at exposure levels below the manufacturer's recommended setting, for certain patient groups. Currently, it is not possible to determine minimally acceptable values for image quality that are applicable to multiple CBCT models.
1 July 2004 in Dentomaxillofacial Radiology
The purpose of this study was to evaluate and to compare the efficacy of a conventional and a digital radiographic method in diagnosing simulated external root resorption cavities. Human dry mandibles containing teeth were covered with bovine muscle slices in order to simulate the soft tissues. Nine teeth from each dental group were investigated. Three periapical radiographs of each tooth were taken in an orthoradial, mesioradial and distoradial aspect using conventional film (Insight Kodak F-speed; Eastman Kodak, Rochester, NY) and a digital sensor (DRS Gnatus System; Gnatus, Ribeirao Preto, Brasil). The teeth were extracted using a forceps and had 0.7 mm and 1.0 mm deep cavities prepared on their vestibular, mesial and distal surfaces at the cervical, middle and apical thirds. Following preparation, each tooth was replaced in its alveolus and new radiographs were taken. Three dental professionals, an endodontist, a radiologist and a general practioner, evaluated the images. A larger number of cavities (P<0.05) were detected by the digital method when compared with the conventional method, for all depths of lesions. The results of this study suggest that the digital radiographic method is more sensitive than conventional radiography to detect simulated external root resorption cavities.
1 July 2018 in Journal of Endodontics
22 April 2014 in Surgical and Radiologic Anatomy
ALAntonio Adilson Soares de Lima
Antonio Adilson Soares de Lima
1 May 2010 in American Journal of Orthodontics and Dentofacial Orthopedics
SBSoraya de Azambuja Berti
APAdriane Bastos Pompermayer
Adriane Bastos Pompermayer
1 April 2004 in Dental Traumatology