Murat Olgun

Murat Olgun

Auto-generated profile, based on publicly available information

Murat Olgun

Konya Teknik Üniversitesi

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2021 in International Journal of Pavement Engineering
Verified
Journal Article
Closed access
ETEkrem Burak Toka
Ekrem Burak Toka
MOMurat Olgun
Murat Olgun
In this study, the usability and performance properties of recycled concrete aggregates (RCA) as granular road base (GRB) and granular road subbase (GRSB) material were investigated. A natural aggregate and the RCAs obtained from concretes with three different compressive strength and mixtures created by adding the RCAs to NA at the ratios of 25, 50 and 75% were used. Physical properties, modified Proctor, resilient modulus, permanent deformation, California bearing ratio (CBR), and permeability tests were carried out on all mixtures. Resilient modulus values (Mr) were obtained using three different resilient modulus models. The highest Mr value among pure RCAs was observed for RCA2 (average of 200 MPa). For the mixture samples, the highest Mr values were obtained in the mixtures containing RCA1 (average of 250 MPa). The minimum of permanent deformation value (ϵp) for the mixtures was obtained when the ratio of the RCA1 in the mixtures was 50% (ϵp = 0.238%). The obtained CBR values were not related to the Mr values, and the highest CBR values were found for the pure RCAs (average of 126%). High permeability coefficient values (average of 9.973×10−6 m/s) were obtained for the RCAs. As a result, it was more appropriate to blend the RCAs with the natural material rather than to use them in pure form. In general, it was appropriate to use 50% of RCAs in the mixtures. It was observed that if concrete compressive strength is as high as in RCA1 (18.5 MPa), RCA can be used even in the mixture at a ratio of 75%.

28 March 2023 in Bulletin of Engineering Geology and the Environment
Verified
Journal Article
Closed access
PDF file
YYYavuz Yenginar
Yavuz Yenginar
MOMurat Olgun
Murat Olgun

5 October 2020 in Construction and Building Materials
Verified
Journal Article
Closed access
MOMurat Olgun
Murat Olgun
AKAskar Kanat
Askar Kanat
ASAlican Senkaya
Alican Senkaya
İEİbrahim Hakkı ERKAN
İbrahim Hakkı ERKAN

11 July 2024 in Bulletin of Engineering Geology and the Environment
Verified
Journal Article
Open access
PDF file
YYYavuz Yenginar
Yavuz Yenginar
MOMurat Olgun
Murat Olgun
The novel approach of the study is implementing the installation procedure of fly ash (FA) replaced cement deep mixing (DM) columns to field cases aiming at managing FA waste and reducing cement utilization. FA replaced cement DM columns (diameter of 30 cm and length of 80 cm) were installed on clayey soils using a laboratory type DM machine. The effect of installation parameters such as the binder dosage, FA replacement ratio, superplasticizer content, water/binder ratio, and the liquidity index (LI) of the soil on column performance was investigated. The design of experiments and optimization process were conducted using the Taguchi method, S/N and ANOVA analyses, and the desirability function method. Observations have shown that the mixing time required for a homogeneously mixed column depends on the LI of the soil and the volume ratio (VR) of the slurry. A key parameter (LI∙VR) is defined to decide the minimum number of the mixing process. The blade rotation number should be minimum of 252 rev/m to obtain a homogeneous soil-slurry mixture. The highest strength of the column was obtained when LI of fresh soilcrete (LImix) is 1.25∙LI. Optimum installation parameters were determined as binder dosage of 425 kg/m3, FA replacement ratio is 40%, superplasticizer content is 3%, water/binder ratio is 0.8, and LI of the untreated soil is 1. In the optimum design, the mixing efficiency of the soil-slurry mixture increased and the best column performance was obtained. In addition, cement utilization and binder cost decrease 40% and 33%, respectively, in FA-replaced cement DM columns. SEM images prove the increase in column performance due to the cementation products (CSH and CAH gels) formed in the microstructure of the column.

14 March 2022 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
ASAlican Senkaya
Alican Senkaya
ETEkrem Burak Toka
Ekrem Burak Toka
MOMurat Olgun
Murat Olgun

17 June 2020 in Challenge Journal of Concrete Research Letters
Verified
Journal Article
Closed access
Esra UrayEsra Uray
Esra Uray
SCSerdar Carbas
Serdar Carbas
İEİbrahim Hakkı ERKAN
İbrahim Hakkı ERKAN
MOMurat Olgun
Murat Olgun
In this paper, the investigation of the optimum designs for two types of concrete cantilever retaining walls was performed utilizing the artificial bee colony algorithm. Stability conditions like safety factors sliding, overturning and bearing capacity and some geometric instances due to inherent of the wall were considered as the design constraints. The effect of the existence of the key in wall design on the objective function was probed for changeable properties of foundation and backfill soils. In optimization analysis, wall concrete weight which directly affect parameters such as carbon dioxide emission and the cost was considered as the objective function and analyzes were performed according to different discrete design variables. The optimum concrete cantilever retaining wall designs satisfying constraints of stability conditions and geometric instances were obtained for different soil cases. Optimum designs of concrete cantilever retaining wall with the key were attained in some soil cases which were not found the feasible optimum solution of the concrete cantilever retaining wall. Results illustrate that the artificial bee colony algorithm was a favorable metaheuristic optimization method to gain optimum designs of concrete cantilever retaining wall.