Xinzhou Dong

Xinzhou Dong

Auto-generated profile, based on publicly available information

Xinzhou Dong

Department of Electrical Engineering, Tsinghua University, Beijing 100084, China

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Sohrab MirsaeidiSohrab Mirsaeidi
Sohrab Mirsaeidi
XDXinzhou Dong
Xinzhou Dong
DTDimitrios Tzelepis
Dimitrios Tzelepis
DSDalila Mat Said
Dalila Mat Said
ADAdam Dysko
Adam Dysko
CBCampbell Booth
Campbell Booth
High-Voltage Direct Current (HVDC) systems are being widely employed in various applications because of their numerous advantages such as bulk power transmission, efficient long-distance transmission, and flexible power-flow control. However, Line-Commutated Converter (LCC) based HVDC systems suffer from commutation failure which is a major drawback, leading to increased device stress and interruptions in transmitted power. This paper proposes a predictive control strategy, deploying a Commutation Failure Prevention Module (CFPM) to mitigate the commutation failures during AC system faults. The salient feature of the proposed strategy is that it has the ability to temporarily decrease the firing angle of thyristor valves depending on the fault intensity to ensure a sufficient commutation margin. In order to validate the performance of the proposed strategy several simulations have been conducted on CIGRE Benchmark HVDC model using PSCAD/EMTDC software. Additionally, practical performance and feasibility of the proposed strategy is evaluated through laboratory testing, using the real time Opal-RT hardware prototyping platform. Simulation and experimental results demonstrate that the proposed strategy can effectively inhibit the commutation failure or repetitive commutation failures under different fault types, fault impedances and fault initiation times.

17 December 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
CZChenhao Zhang
Chenhao Zhang
SGSong Guobing
Song Guobing
XDXinzhou Dong
Xinzhou Dong
Hybrid AC/DC transmission grids require high-speed operation and high reliability for relay protection. Traditional derivative-based traveling wave protection methods have exposed the problems of low sensitivity and low reliability. In this paper, the fault traveling wave is analyzed considering the attenuation, distortion, and boundary effect of the DC transmission line as well as three converter types. The expressions of the fault initial traveling wave are derived and the conclusions show that, 1) the expressions of the fault initial traveling wave at the end of the transmission line have the formation of a(1-exp(-bt)); 2) the index of the exponential function in the fault initial traveling wave expression is related to the fault location, and is not affected by the fault impedance and line attenuation. Then a Levenberg-Marquart fitting method is proposed to fit the measured zero-mode fault current initial traveling wave and extract the index coefficients. Finally, a novel traveling wave protection method for DC transmission lines is proposed using the obtained index coefficients. The simulation results show that, 1) the proposed protection method can complete fault identification within 1 ms, even with high fault impedance; 2) the proposed protection method has high robustness to the influence of the noise.

20 November 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
CZChenhao Zhang
Chenhao Zhang
SGSong Guobing
Song Guobing
TWTing Wang
Ting Wang
XDXinzhou Dong
Xinzhou Dong
The performance of the traditional derivative-based non-unit traveling wave protection (TWP) in high voltage dc (HVDC) grids shows the problem of low-sensitivity when high-impedance faults occur. In this paper, the characteristics of the fault initial traveling wave are analyzed first, two conclusions can be drawn: i) the distortion degree of the fault initial traveling wave is related to the fault location, ii) the amplitude of the fault initial traveling wave is related to the fault impedance. Then a zero-sequence current fitting method is proposed to obtain parameters respectively reflecting fault impedance and fault distance. When a fault occurs, a fault information extraction method based on the fitting parameters will give the estimation interval of the fault impedance, which provide reference for the adaptive threshold value selection of TWP. In this way, the influence of the fault impedance on TWP can be eliminated. A ±400 kV modular multilevel converter (MMC) HVDC grid is built in PSCAD/EMTDC. The verification of the proposed method considers different installation positions of the current limit inductor. The simulation results show that the proposed method can fast and correctly identify the dc line faults and effectively improves the protection sensitivity in detecting high-impedance faults.

26 March 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Sohrab MirsaeidiSohrab Mirsaeidi
Sohrab Mirsaeidi
XDXinzhou Dong
Xinzhou Dong
DSDalila Bt Mat Said
Dalila Bt Mat Said
Commutation failure is one of the most frequent failures in Line-Commutated Converter based High-Voltage Direct-Current (LCC-HVDC) systems which may lead to the outage of HVDC links, and thus affect the performance of the power system. Most commutation failures are caused by voltage reduction due to AC system faults. In this paper, a Commutation Failure Prevention Module (CFPM) is developed which inserts the optimal value of resistance proportional to the reduced extinction angle in series with the fault current path using a simple switching method. When a fault occurs at the inverter AC side, a Self Turn-off Switch (STS) starts switching with a prespecified frequency and controlled modulation index which limits the fault current to the desired value and inhibits commutation failure. The salient feature of the proposed CFPM is that it is fully controllable. In addition, despite the available controller modification methods which are not effective for low-impedance faults, the proposed CFPM can prevent commutation failure regardless of the fault severity. The practical performance and feasibility of the developed CFPM is validated through laboratory testing, using the real-time Opal-RT hardware prototyping platform. The experimental results demonstrate that the proposed strategy can effectively eliminate the commutation failure or repetitive commutation failures under different fault types.

16 March 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ALAoyu Lei
Aoyu Lei
XDXinzhou Dong
Xinzhou Dong
VTVladimir Terzija
Vladimir Terzija
An increasing number of Extra-High-Voltage (EHV) and Ultra-High-Voltage (UHV) transmission lines have motivated the need for ultra-high-speed line protection. Traveling-wave directional protection has the advantages of ultra-high-speed operation and high sensitivity, but its reliability is doubted due to its dependence on detecting the wave-heads of traveling waves and the limitation of the limited bandwidth of the coupling capacitive voltage transformer. Incremental-quantity directional protection is another ultra-high-speed alternative. Aiming at improving the reliability of a directional relay (namely the core of a directional protection) without compromising its ultra-high-speed operation, this paper proposes a novel ultra-high-speed directional relay based on correlation of incremental quantities. The incremental voltage and current within a specific window only consist of some specific fault-generated traveling waves. Therefore, the incremental voltage is in approximately direct proportion to the incremental current. The proportional coefficient is positive or negative in the case of a reverse fault or a forward fault, respectively. The correlation coefficient of the incremental voltage and current, processed by an averaging filter, is used to identify the fault direction. Extensive simulations verified that the proposed directional relay can serve as an ultra-high-speed and reliable directional relay for non-, shunt-, or series-compensated EHV/UHV transmission lines.

16 November 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Sohrab MirsaeidiSohrab Mirsaeidi
Sohrab Mirsaeidi
XDXinzhou Dong
Xinzhou Dong
Cascading fault is one of the serious challenges in hybrid AC/DC power grids which initiates from a DC or a severe inverter AC fault and leads to a blackout in the inverter AC side. However, the existing commutation failure inhibition approaches are not effective in prevention of cascading faults caused by DC fault. In order to resolve the challenge, this paper first develops a Hybrid AC/DC Relay based on positive-sequence component which can detect and locate the fault events in hybrid AC/DC networks. Subsequently, an integrated control and protection scheme is presented using the developed HADR and a TCSC. The proposed scheme has the ability to prevent the blackouts caused by cascading fault through transmission capacity enhancement of the AC line and load-shedding in the inverter AC system. The salient feature of the proposed scheme is that it provides a very economical way to compensate for the loss of power caused by HVDC line outage without the need for communication. The practical performance of the proposed scheme is validated through laboratory testing, using the real-time Opal-RT hardware prototyping platform. The experimental results demonstrate that the proposed strategy can effectively inhibit the blackouts caused by cascading fault in hybrid networks.